Site visit or send-in evaluation
Feedback diagnosis, Installation, Alignment. Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
A suitable bench can separately assess 1 Vpp track quality and SEW-supported absolute communication. Confirm the exact AS7W adapter, software option and allowable write operations with Mitchell before assigning a JX test. A safety function must be validated on the installed system.
SEW-EURODRIVE AS7W 13630776 Sin/Cos and SEW RS-485 Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is 13630776. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
Manufacturer device order code
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| AS7W · 13630776 | SEW safety-rated encoder with connection cover per supplement. | SEW .W feedback, sin/cos plus SEW-specific RS-485. |
| AS7W · 13630768 | SEW lists this ID without the connection cover. | Same named feedback option. Verify required cover, fitting and safety documentation. |
| AS7W service kit · 13642855 | A separate SEW kit for listed motor frames. | Check the complete motor order and the latest SEW kit table before ordering. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Supply | SEW .W data table specifies 7–30 V DC and up to 150 mA. |
| Analog tracks | 2,048 sin/cos periods per revolution at nominal 1 Vpp. |
| Absolute output | 13 bits within a turn and 16-bit turn count in the SEW table. |
| Data interface | RS-485, 9,600 baud in the cited table. SEW specifies a departure from standard HIPERFACE data communication. |
| Connection cover | 13630776 includes the cover. 13630768 is without it. |
The table identifies the assembly each value applies to. Main technical PDF.
Mounting and fit
Check the complete SEW DR-family motor and feedback designation against the applicable encoder add-on instructions. Photograph the torque support, mounting face and cover orientation. For a safety-rated assembly, use the SEW installation and validation procedure for that exact motor and feedback option.
Interface and measuring method
The analog tracks follow HIPERFACE sin/cos signal definitions. SEW says the digital RS-485 portion differs from standard HIPERFACE and is intended for the specified SEW electronics.
A healthy analog track on a bench does not establish absolute-data compatibility. Choose the SEW-supported receiver and verify position and configuration there.
Verified wiring
Use the exact SEW connection-cover and drive-card diagrams. At the cover identify supply/return, the two analog differential pairs, RS-485 and the shield from that diagram. Keep the motor-end terminal view separate from the drive-end X15 view and verify the installed variant before probing.
Cables inside the motor and at the machine
SEW’s MOVIDRIVE installation tables list DR71–DR132 with ES7S, ES7R or AS7W and the DEH11B connection. Use the table for the actual housing, cable type, length and drive card.
The service kit ID identifies a service assembly. Confirm the encoder-to-cover connection and the cover-to-drive harness separately.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Sine/cosine signal present but no absolute value | Check the SEW .W data mode and receiver. Verify continuity on the isolated RS-485 pair and compare the drive configuration with the motor order. |
| Intermittent after cover replacement | Verify the cover type, terminal seating, routing and sealing against the supplied drawing. |
| Safety channel fault after work | Keep the safety function out of service until the documented validation is complete. Record the drive and safety diagnostics. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
SEW documents AS7W on specified DR motor configurations and in MOVIDRIVE feedback tables. Determine the frame, drive and feedback card from the installed labels. Retain the encoder safety configuration when the machine relies on it.
Angle of alignment and commissioning
Follow the SEW motor and feedback instructions for installation and functional safety validation. Save authorized configuration data before work. Check direction and position against the controlled axis reference before returning the machine to service.
Drawings, pin maps and manuals
- Main technical PDF. SEW functional-safety supplement, section 1.1. Distinguishes AS7W encoder IDs with and without the connection cover.
- Manufacturer reference. SEW interface specification for AS7W, AV7W and AG7W. See the warning about the RS-485 portion.
- SEW MOVIDRIVE operating instructions. Find the DR71–DR132 / AS7W cable table under DEH11B.
- SEW encoder connection documentation. Locate the exact .W and connection cover before using any terminal table.