Identify the fitted part
| Guide scope | SEW-EURODRIVE CFM71S / BR / RH1M — motor feedback application |
|---|---|
| Feedback identity | RH1M; fitted label and connector to verify |
| Model / configuration identifier | CFM71S / BR / RH1M |
| Motor order scope | Documented frame, brake and feedback configuration; not a complete winding, thermal-sensor or connector order |
| Interface | RH1M resolver |
| Starting connection | TI-5908 only for the matching 12-contact M23 resolver connection; verify winding pairs, excitation and connector view. |
Specialist testing: connection before conclusion
| TI-5000JX bench scope | Named SEW CMP/CFM resolver evaluation, conditional on actual excitation, ratio, winding pairs, connector and supported tester setup. |
|---|---|
| Starting lead / fixture | TI-5908 only for the matching 12-contact M23 resolver connection; verify winding pairs, excitation and connector view. |
| Profile / memory scope | Verify excitation, winding pairs, transformation ratio and fitted alignment. RH1M has no serial motor memory. |
| TI-3000JX motor-run scope | Motor-run evaluation is conditional on the exact TI-3000JX motor/feedback profile, poles, phase order, alignment, power wiring, load restraint and amplifier envelope. A catalogue maximum or successful feedback bench test does not promise a full-rating run. Confirm the fitted brake circuit and controlled release before rotation. |
Mitchell names the SEW CMP/CFM resolver family. The OEM BR outline is on page 101; RH1M values are on page 144. Verify installed software, the actual sensor option and fixture before connection. A bench result describes the tested configuration; it does not clear the drive, machine cable or loaded axis.
Production and replacement status
The linked manufacturer document identifies this catalogue configuration. Current production, availability and any approved successor require confirmation against the complete fitted order. A downloadable manual does not prove present stock. Compare voltage, winding, mounting, shaft, brake, feedback, connector and stored motor-data requirements before accepting a replacement.
Specifications and interface
| Feedback technology | RH1M resolver |
|---|---|
| Frame / brake / feedback configuration | CFM71S / BR / RH1M |
| Motor square flange | 105 mm |
| Motor shaft diameter | 19 mm; see drawing for tolerances |
| Overall axial length including shaft | 345 mm, with BR brake |
| Outline reference | Printed page 101 of 19424019/EN, March 2017 |
| Order scope | Documented frame, brake and feedback configuration; not a complete winding, thermal-sensor or connector order |
| RH1M sensor | Two-pole resolver; one resolver pole pair |
| OEM excitation reference | 7 V at 7 kHz; verify the fitted revision and permitted test setup |
| Transformation ratio | 0.5 ±10%, CFM catalogue printed page 144 |
| Memory scope | No serial-encoder motor-memory read/copy workflow |
| Service values | Exact feedback coupling dimensions, pin map, tightening torque and permitted retention method require the fitted assembly drawing. |
RH1M is a resolver. Excitation and both analogue winding responses must be assessed together through a full mechanical revolution. A lost winding pair, poor contact, incorrect excitation or altered phase relationship can each cause incorrect position. The two-pole designation describes the resolver, not the motor pole count. There is no serial data channel or retained multiturn revolution counter to diagnose.
Mechanical fit and retention
Record the incoming shaft datum, pilot, bolt circle, rear clearance, cable exit and feedback retention before removal. Inspect play, debris, moisture and damaged contacts. Follow the exact assembly drawing for fits and fasteners; motor flange dimensions do not establish encoder coupling dimensions or tightening torque. Use the CFM71S brake outline on printed page 101. Its 105 mm flange and 19 mm shaft are independent dimensions. Verify pilot, bolt circle, shaft projection, rear housing and cable bend clearance from that same drawing. The main BR drawing gives LS = 371 mm for the RH1L/AK1H/EK1H rear package. RH1M is 26 mm shorter, so 371 − 26 = 345 mm. Do not quote the uncorrected LS as RH1M length. Plug clearance and any hand-release arrangement need additional space beyond the stated axial envelope.
CFM71S / BR / RH1M identifies a 105 mm square flange, 19 mm shaft and 345 mm overall axial length including the shaft, with BR brake. The complete winding, speed, thermal-sensor and connector suffixes remain to record from the fitted nameplate.
Wiring and connector boundaries
Keep motor power, protective earth, feedback and temperature circuits separate. Match contact numbering, keying, gender and mating-face versus wire-side view. A mechanically mating connector does not establish a pin assignment. Establish excitation, sine and cosine winding pairs from the actual connection drawing. Check continuity and isolation only with the assembly disconnected and the permitted measurement method. Excitation frequency, transformation ratio and polarity must match the fitted resolver and selected profile. Do not use a HIPERFACE power/data pin map for this resolver connection.
TI-5908 only for the matching 12-contact M23 resolver connection; verify winding pairs, excitation and connector view.
The BR brake is a separate circuit from feedback. Its family code does not establish coil voltage, current, holding torque, release time or emergency-stop rating. Check the fitted brake label and OEM circuit, including the control and suppression components. Separate a failure to release or mechanical drag from a feedback fault. Never route brake power through the feedback fixture. Record release and re-engagement behaviour under an agreed, restrained test setup.
Internal loom and machine cables
Record the internal encoder-to-motor loom separately from the external machine cable and bench fixture. The internal loom part number is not established by the frame or interface alone. Obtain both connector faces, the assembly diagram and the correct contact view. Match cable length, shielding, temperature rating and fixed or flexing duty to the installation. A Mitchell test lead identifies a test connection; it is not an OEM replacement machine cable.
Practical fault checks
Isolation and measurement conditions
Secure moving loads, isolate and lock out the relevant energy sources, follow the specified discharge time and have a qualified technician verify isolation before physical inspection or resistance checks. Disconnect both cable ends before continuity/short testing. Powered supply measurements, rotation, retention work and alignment require the approved fixture and procedure.
| Identify the exact configuration | CFM71S / BR / RH1M identifies a 105 mm square flange, 19 mm shaft and 345 mm overall axial length including the shaft, with BR brake. The complete winding, speed, thermal-sensor and connector suffixes remain to record from the fitted nameplate. |
|---|---|
| Intermittent fault during cable movement | After isolation and disconnection at both ends, inspect flex points, pin engagement, contamination and earlier repairs. Compare continuity and unintended shorts against the correct diagram, accounting for intentional shield bonds. |
| Unstable position or missing feedback | Verify the actual sensor profile, matched excitation or DC supply, contact view and fixture. Inspect both analogue paths where applicable. A connector that mates mechanically can still have an incompatible pin assignment. |
| Position reads but the drive rejects it | Check the resolver winding relationship, phase convention and exact motor profile. A serial-memory reset is not an RH1M diagnostic. |
| Replacement dimensions look close | Compare this exact flange, shaft, feedback housing, brake and connector arrangement with the linked drawing. Do not use magnet-stack length, family digits or a similar power rating as the complete mounting envelope. |
| Holding, drag and load restraint | The BR brake is a separate circuit from feedback. Its family code does not establish coil voltage, current, holding torque, release time or emergency-stop rating. Check the fitted brake label and OEM circuit, including the control and suppression components. Separate a failure to release or mechanical drag from a feedback fault. Never route brake power through the feedback fixture. Record release and re-engagement behaviour under an agreed, restrained test setup. |
Alignment, reference and memory
Preserve incoming references and readable drive settings before disassembly. A smooth position reading alone does not prove electrical alignment or machine home position. Use the fitted SEW resolver alignment procedure and exact motor profile. Mitchell documents a common SEW convention of +U/−V at 60 electrical degrees and +U/−W at 120 electrical degrees for most applicable motors. Confirm the actual motor follows that convention before using it. RH1M has no serial motor memory from which to recover a unique offset. Preserve the mechanical reference, phase convention and drive parameters before removal; verify the machine reference separately after repair.
Motor and drive applications
CFM71S / BR / RH1M identifies a 105 mm square flange, 19 mm shaft and 345 mm overall axial length including the shaft, with BR brake. The complete winding, speed, thermal-sensor and connector suffixes remain to record from the fitted nameplate.
Record the compatibility chain separately: complete motor order, actual feedback option, internal loom, bulkhead, machine cable and drive configuration. Similar power, a familiar connector shell or a shared protocol name cannot establish the whole chain. Any proposed replacement must also satisfy the mechanical, electrical and stored-data requirements of the specific machine.
Drawings, manuals and evidence
- Mitchell — SEW Servo Motors — Mitchell names the SEW CMP/CFM resolver family. The OEM BR outline is on page 101; RH1M values are on page 144.
- Mitchell — SEW Standard Alignment — Documented resolver examples; confirm the exact motor procedure
- SEW — CFM71–112, 19424019/EN (03/2017) — Brake outline, printed page 101; overall axial length includes shaft
- OEM feedback and package cross-check — Resolver specification, page 144
Source review: 20 November 2026. Obtain complete fitted motor and feedback labels, service ID, internal loom details and the correct connector mating-face drawing. Confirm the linked document revision and enabled test setup before extending replacement, wiring or motor-run claims.
Common questions
What should accompany a CFM71S / BR / RH1M enquiry?
Send clear photographs of the motor and feedback labels, every suffix/ID, both connector faces, drive model, exact alarm and the circumstances of the fault. Include recent wiring, bearing, encoder or parameter work.
Can the listed Mitchell lead be used as a replacement machine cable?
The lead is documented for the stated test connection. OEM internal looms and machine extensions require their own part numbers, pin maps and mechanical ratings.
Does a successful feedback bench test prove that the motor can be run?
Motor-run scope remains conditional on the exact motor/feedback profile, poles, phase order, alignment, power wiring, restraint and amplifier envelope. Frame size or bench support does not establish full-rating run capability. A complete run assessment also checks motor power, brake, protection and mechanical conditions.
When does a site visit or send-in evaluation make sense?
A site visit can help when the fault depends on the drive, installation or moving cable. Send-in evaluation can isolate a removable feedback assembly or supported motor configuration. Agree scope, packing, availability and turnaround with SpareFaber after identification.
What a useful service record contains
Keep the incoming condition distinct from the result after cleaning, rewiring or adjustment. Record the exact alarm text, whether it appears at power-up or during motion, the direction and speed range involved, and whether temperature or cable position changes it. Include recent bearing, winding, feedback or drive-parameter work. These observations help decide whether a site visit can reproduce the fault or a detached assembly can answer the same question on the bench.
An evaluation report should identify the motor and feedback actually received, the tested connection boundary, selected profile, fixture, supply or excitation, and the observations obtained. Preserve the original memory report where applicable. Separate a confirmed defect from an unresolved condition and state any tests limited by missing drawings, mounting hardware or the machine itself. A repair recommendation should name the affected assembly and the evidence supporting it, with replacement availability and turnaround confirmed after inspection.
Request a scoped service evaluation