Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
A compatible EtherCAT master can verify link state, diagnostics and position through a controlled turn. Read the parameters first. Separate device faults from the harness and controller with a matching test lead. Exact Mitchell support is unverified.
SICK AFM60A-S1EB018x12 EtherCAT Absolute Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is AFM60A-S1EB018x12. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| AFM60A-S1EB018x12 / 1059061 | Servo flange, 6 mm solid shaft with flat, 10 mm shaft length. | 18-bit angle, 12-bit turns, EtherCAT CoE. |
| AFM60A-S4EB018x12 / 1059060 | Face-mount flange, 10 mm solid shaft, 19 mm length. | EtherCAT CoE. Verify mechanical fit before replacing. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Position | 262,144 steps per turn and 4,096 turns at maximum resolution. Read installed scaling. |
| Supply and connection | 10–30 V DC, maximum 3 W without load. One A-coded power connector and two D-coded EtherCAT connectors. |
| Fit | 6 mm diameter by 10 mm shaft length, servo flange. Use the exact mechanical drawing. |
| Protection | IP65 shaft side and IP67 housing side under the published conditions. |
| Profile | CoE with encoder profile CiA DS-406. Confirm the matching device description in the controller. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
Check the exact servo flange and shaft flat before selecting a coupling. Align the hub and keep thrust and radial load within the datasheet conditions. Provide access to the power and two network connectors. Check that the shaft follows the machine without slip.
Interface and measuring method
EtherCAT carries position and diagnostic data over the network. The controller reads the configured CoE objects and cyclic process data. The raw resolution, configured steps and PLC units can differ. Match the exact device description, count direction and configured preset.
Verified wiring
Use the numbered drawings for the male A-coded supply plug and each female D-coded port. Match mating views before landing a conductor.
| Port | Contacts |
|---|---|
| Power A-coded | 1 US +10–30 V DC, 3 GND. 2 and 4 unassigned. |
| EtherCAT D-coded | 1 TxD+, 2 RxD+, 3 TxD−, 4 RxD−. |
Use screened network leads per the data sheet. Verify the specified network entry and exit ports and cable continuity separately from supply.
Cables inside the motor and at the machine
Choose the SICK-recommended screened M12 D-coded network lead and the separate mating A-coded supply lead. Match genders, bend space, machine length and controller port. Use the accessory list for the actual cable length and connector style.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Device fails to enter operational state | Check DC supply, both network connections, master configuration and exact device description. |
| CoE reads work, cyclic value is stale | Compare PDO configuration and state with the controller project. |
| Value is smooth but offset or reversed | Check coupling, configured direction, scaling and preset at the machine datum. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Use on an EtherCAT-controlled rotary axis with the matching device profile and power. Verify the exact machine's device configuration and fault behavior. The mechanically different 1059060 remains a separate product.
Angle of alignment and commissioning
Capture the existing network setup, PDO mapping, scaling and preset. Align the coupling, then confirm direction and raw position at a known datum. Apply a new preset only under the approved commissioning procedure.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- 1059060 alternate mechanical configuration. Use its own shaft and flange drawing.
- AFS/AFM60 EtherCAT family product information. Identifies product options and network support.