Site visit or send-in evaluation
We inspect the two-wire DSL link and motor cable, then check the taper fit and original application data before installation or commissioning. Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
Mitchell's TI-5743 is listed as a direct four-pin DSL lead. Verify the exact mating plug, compatible profile, firmware and module before connecting 1112142. An approved DSL diagnostic tool can separate link errors, temperature data and position problems. Verify TI-3000JX support separately for any complete motor run.
SICK EDS35-2KF0A020A-40 1112142 HIPERFACE DSL Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is EDS35-2KF0A020A-40. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| EDS35-2KF0A020A-40 / 1112142 | Packaged single-turn device with tapered shaft, stator coupling and mounting hardware as listed by SICK. | 20-bit HIPERFACE DSL feedback. Separate four-pin communication and two-pin thermistor plugs. |
| EDS35-2KF0A020A | Feedback unit listed within the 1112142 package. | Use the packaged ordering ID and unit label together when comparing the delivery contents. |
| EDM35-2KF0A020A / 1090711 | Related EDS/EDM35-S family hardware. Compare mating drawing. | Multiturn configuration. Verify the motor's drive and approved safety configuration. |
Production and end-of-life status
SICK publishes a datasheet for 1112142. Confirm production, orderability and any replacement for the exact package with SICK.
Specifications
| Parameter | Value and scope |
|---|---|
| Position | 20-bit single-turn position for standard feedback |
| Supply and load | 7–12 V at the encoder. Up to 150 mA with SICK’s specified DSL master circuit. |
| Feedback connection | Four-pin male device connector with two active DSL conductors |
| Temperature input | Separate two-pin thermistor connection on the device |
| Motor mounting | Tapered shaft and stator coupling. Exact motor mating dimensions are in the 1112142 datasheet. |
| Speed and enclosure | ≤12,000 min⁻¹. IP40 with cover closed and mating connector fitted. |
The table identifies the assembly each value applies to. Main technical PDF.
Mounting and fit
The taper centres the feedback rotor on the drive shaft. The central screw and stator coupling locate the assembly. Compare the motor's drive-shaft drawing, bearing references and mating face with SICK’s pages 4–5. Keep the encoder cover and both leads clear.
Use the OEM's approved mounting sequence and fasteners. In a safety application, verify the exact encoder, fastener and mounting conditions against the motor's approved assembly procedure.
Interface and measuring method
HIPERFACE DSL carries supply and digital data over the same pair. A drive with a compatible DSL master separates the communication from the supply and reads the position and diagnostics. The thermistor is a separate input to the encoder. A normal average supply reading does not prove that the link is delivering valid frames.
Verified wiring
These are device cavity numbers from the SICK 1112142 sheet. Orient the latch and pin 1 by the SICK connection drawings on pages 5–6. The motor bulkhead or hybrid power cable uses the motor maker's pin map.
| Plug | Pin | Function |
|---|---|---|
| 4-pin DSL | 1, 4 | Unused |
| 4-pin DSL | 2 | +US / DSL+ |
| 4-pin DSL | 3 | GND / DSL− |
| 2-pin thermistor | 1 | T+ |
| 2-pin thermistor | 2 | T− |
The DSL mating housing specified by SICK is JST GHR-04V-S. The temperature plug is Harwin M80-8990205. Identify both before testing.
Cables inside the motor and at the machine
The SICK datasheet lists a 0.36 m twisted shielded flying-lead option DOL-0B02-G0M3AC2 (2108944) and a 0.2 m unshielded option DOL-0B02-G0M2XC2 (2079920). Compare the approved cable and screen routing for your motor. OEM hybrid cables and bulkhead connector pin maps vary.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Supply present, encoder absent | Check both data/supply conductors, shield routing, terminations and drive DSL compatibility. Read the drive link errors. |
| Errors only when the motor moves or the load changes | Inspect the hybrid cable and connectors. Correlate link errors with cable flex or interference and verify the grounding arrangement. |
| Temperature fault with steady position | Inspect the separate thermistor plug and sensor circuit under the motor's approved procedure. |
| Fault begins after an encoder replacement | Confirm unit code, supported drive firmware, saved motor data and OEM commissioning. Verify any safety checks before enabling service. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
The exact SICK order is documented by the manufacturer. Match the motor ID and the drive's DSL feedback profile, power cable and safety requirements before choosing a replacement. The motor OEM order and harness number still need confirmation.
Angle of alignment and commissioning
Preserve the motor's original offset and device data if the OEM provides a verified read procedure. Record which values are stored in the encoder and which are in the drive. Restore only through the approved commissioning route for that same motor and encoder. Follow the equipment maker's required validation when the feedback participates in a safety function.
Drawings, pin maps and manuals
- Main technical PDF. SICK order 1112142. Pages 4–6 show the taper, motor mating dimensions and separate supply/communication and thermistor pin assignments.
- Manufacturer reference. SICK EDS/EDM35 family product information. Apply the exact 1112142 datasheet for the covered package.
- SICK HIPERFACE DSL master integration manual 8017595. Supply and data coupling, master interface and diagnostics.
- Mitchell manufacturer cable index. Direct DSL lead and adapter family.
- SICK 1090711 datasheet. Related multiturn variant.