Site visit or send-in evaluation
Share the feedback label, complete motor or machine order, drive model and alarm. Include both connector faces and note whether the issue followed a cable change, replacement or mechanical work.
What specialist testing can show
TI-5000JX bench. Mitchell has a legacy SNS family workflow. Exact S01 support and its Hirose breakout require confirmation.
TI-3000JX motor run. Exact motor run setup open
SICK Stegmann SNS50-TFA0-S01 1034101 Legacy Sin/Cos Feedback technical reference
Find your part number
Use the full fitted label. A motor order identifies the assembly and should be recorded separately from an encoder part number.
| ID or order code | Identification and scope |
|---|---|
| SNS50-TFA0-S01 | Exact SICK S01 device. The SICK sheet shows its own Hirose connection and resolution-select line. |
| 1034101 | Manufacturer item on the exact SICK document. |
| SNS50 / SNS60 | Mitchell’s family reference for legacy SNS testing. Verify the interface of each suffix. |
Production and end-of-life status
Confirm current orderability and any successor for the exact ID with the manufacturer or motor OEM. The dated documentation identifies the configuration.
Specifications
| Parameter | Verified scope |
|---|---|
| Fine process data | 1,024-period sine and cosine mode in the S01 document. |
| Coarse mode and reference | One-period sine and cosine mode and a separate reference in the S01 document. |
| Connection | S01 dual-row Hirose plug with mode-select and EEPROM contacts. Use the exact view and signal ratings. |
Mounting and fit
Inspect the fitted stator attachment and match the S01 mechanical drawing before considering a replacement. Record the spindle or motor order and the actual internal cable routing.
Interface and measuring method
The exact S01 sheet describes fine and coarse sin/cos selected via a hardware line. Mitchell describes a family SNS procedure where a serial line can switch into index mode. Establish which wiring and control scheme the fitted unit uses before applying that procedure.
Wiring and connector scope
These contacts are a limited identification reference for the S01 Hirose plug in the exact SICK sheet. The manufacturer document provides the complete view, analog levels and remaining contacts. Check those details before connecting an instrument.
| Contact | Documented signal |
|---|---|
| a5 | 5 V supply |
| a6 / a8 / a10 | 0 V contacts |
| a7 | Resolution select |
| a9 | Reference |
| b5 / b9 | SIN / COS |
Cables inside the motor and at the machine
Mitchell documents TI-5104 and SNS-specific cable wiring for the supported legacy SNS arrangement. Its direct TI-5069 lead is described for an 8-pin plug. Confirm a separate documented adapter for the S01 Hirose layout before bench connection.
Fault checks
Before inspection. Follow the site’s isolation and lockout procedure. Secure any load against movement, allow the specified discharge time and have a qualified technician verify isolation. Check resistance on a disconnected harness at both ends. Use the documented shield and return connections.
| Observation | What to verify |
|---|---|
| Signal tracks look healthy but resolution is wrong | Check the S01 resolution-select state and the receiver’s expected mode. |
| Reference is absent with fine sin/cos present | Trace the separate reference contact and confirm the selected mode and connector view. |
| Generic SNS test cable does not match | Identify the Hirose layout from the S01 sheet before selecting a fixture. |
Motor and drive applications
Allen-Bradley 8720 or Fagor PM, family references Check the exact ID, drive and connector before applying an installation or test procedure.
Explain why index mode changes what the shared line carries. Confirm suffix, motor fit and cable wiring separately.
Angle of alignment and commissioning
Verify fine and coarse readings and the reference in the exact receiver setup. Follow the OEM procedure for spindle reference and alignment. Record the original fitted configuration and avoid assuming that the serial/index sequence applies to S01.
Drawings, pin maps and manuals
- Stegmann training chapter. Overview and SNS50/60. Named devices, applications and cable scope.
- Mitchell SNS test sequence. Family guidance for the serial/index variant and compatible test hardware.
- SICK SNS50-TFA0-S01 technical sheet. Exact device 1034101, signal modes, pin assignment and mounting.