Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
Use a suitable SSI receiver to read position at known points and confirm clock/data timing. Where used, compare the analog pairs with the supported setup. Verify exact Mitchell fixture and word support if applicable. A motor-run tester is outside this standalone linear measurement application.
SIKO MSA111C-S SSI Absolute Magnetic Linear Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is MSA111C-SSI-K-H-S. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| MSA111C-SSI-K-H-S | Reference configuration decoded from SIKO’s order table. Horizontal connector, no temperature sensor. | SSI interface, software S. Confirm all four fields on the fitted label. |
| MSA111C-S | SIKO's standard SSI software designation. Check the remaining hardware order fields. | Use the SSI software and commissioning manual. |
| MSA111C DQ variants | Separate hardware and mating connector options. | DRIVE-CLiQ configuration. Use its own interface and safety instructions. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Scale | SIKO MBA111 magnetic tape. Observe travel and mounting direction in the drawing. |
| Reading distance | Up to 0.3 mm without masking tape per SIKO datasheet. Follow the installation drawing and allowances. |
| SSI power | 4.5 to 30 V DC for SSI/RS485. The data sheet specifies up to 1.2 W for those interfaces. |
| Feedback paths | SSI absolute word plus separate analog sin/cos output on the documented SSI sensor. |
| Connection | 12-pin A-coded M12 for SSI. SSI clock limit is up to 750 kHz subject to cable length. |
The table identifies the assembly each value applies to. Main technical PDF.
Mounting and fit
Install the MBA111 tape and sensor using the correct datum and reading direction. Check gap and lateral alignment through the full travel. If the gap changes as the carriage moves, inspect rail condition and bracket stiffness before replacing electronics. Use the SIKO mounting and distance gauge guidance for the actual tape stack.
Interface and measuring method
The controller clocks an SSI word out of the sensor to get absolute position. The separate analog sin/cos output can carry speed or fine motion information for a compatible receiver. Check which path the controller uses, then verify configuration, timing and cable limits for that path.
Verified wiring
Use the SSI contact-side drawing in SIKO 84956DE5 for the device connector. The related RS485 and DQ versions have different pin functions.
| Contact or group | Function |
|---|---|
| 5 / 12 | +UB / 0 V |
| 2 / 3 | SSI data+ / data− |
| 11 / 4 | SSI clock+ / clock− |
| 7 / 6 | Sin / inverted Sin |
| 9 / 8 | Cos / inverted Cos |
| 1 / 10 | Adjust / Config. Use the approved SIKO procedure. |
Cables inside the motor and at the machine
SIKO lists KV12S2 for the applicable 12-contact SSI extension and identifies mating sockets 85277 straight and 85278 angled. Check horizontal or vertical exit, length and the exact terminal drawing. If the existing connector is the DQ version, match its separate hardware and lead.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Loss of absolute reading at one point on the axis | Inspect local tape and mounting gap, then compare the SSI and analog paths separately. |
| Good analog response and no valid SSI word | Check clock, data and receiver configuration against the actual S software and cable length. |
| Fault began after a head or cable swap | Read the full order key and check 12-pin SSI functions, travel direction and calibration. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
This is a linear measuring system. Identify the sensor, MBA111 tape and the controller input, then match the SSI software and connector to the machine.
Angle of alignment and commissioning
Set the reading gap and travel alignment before adjusting the datum. Use SIKO’s approved calibration and controller procedure for the fitted unit. Verify motion direction, position at known travel points and the active reference after replacement.
Drawings, pin maps and manuals
- Main technical PDF. SIKO 84956DE5 installation documentation. Use the MSA111C SSI pin and mechanical sections.
- Manufacturer reference. Match the exact order code or the identified motor option.
- SIKO MSA111C technical data. MBA111 tape, SSI supply, order key and accessory numbers.
- SIKO MSA111C-S SSI software manual. SSI configuration and operation for software S.