What specialist testing can show
TI-5000JX bench. Mitchell names the AG661 SSI branch. Confirm connector, SSI settings and fitted device before testing.
TI-3000JX motor run. Exact motor-run setup open.
Starting lead. Exact lead open. Match the fitted connector to a documented drawing.
SICK Stegmann AG661 SSI Encoder for Siemens 1FT5 technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| AG661 | SSI encoder identified by Mitchell on Siemens 1FT5. Capture the complete encoder suffix and motor order. |
| AG100 | A different Stegmann SSI example used on Indramat MAC. Match its own connector, scaling and mounting. |
| Other 1FT5 feedback builds | The same motor series also appears with different feedback paths. Confirm the device label and OEM drawing before using this guide. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Interface | SSI clock and data in Mitchell’s documented AG661 branch. |
| Incremental channels | The named Stegmann SSI arrangement has no incremental outputs. |
| Fitted configuration | Verify word length, code format, supply, clock rate and the actual connector against the fitted documentation. |
Interface and measuring method
The drive sends an SSI clock and reads a serial position word. Stable supply alone does not show whether clock reaches the device or whether the receiver can decode the returned data. Treat direction and scaling as separate checks.
Mounting and fit
Compare the 1FT5 rear assembly, encoder seat and shaft connection with the full motor order. Record installed position and coupling before disassembly. A similar SSI connector does not establish fit.
Wiring and connector scope
Identify the exact feedback plug and obtain the fitted AG661 pin view. Trace the clock and data pairs separately and verify shield termination from the Siemens drawing. Mitchell’s AG100 cable example does not establish an AG661 pin map.
Internal motor and machine cables
The exact Mitchell lead and OEM internal loom are open for the installed suffix. Use photos of both connector faces and the motor and encoder labels to match a drawing before testing.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Drive reads no position | Check supply and clock at the approved breakout. Separate a missing clock from a failed data response. |
| Position is stable but implausible | Verify SSI word length, format and direction against the installed receiver. Check the coupling and reference. |
| Fault is present only on the machine | Compare the machine harness and shield with a verified bench connection, then check drive configuration. |
Angle of alignment and commissioning
Preserve the incoming mechanical position and the drive’s reference settings. Check the role of the separate motor commutation feedback if fitted. Follow the OEM procedure to verify reference and position after fitting.
Motor and drive applications
Siemens 1FT5
Identify the SSI variant rather than using the HIPERFACE profile. Check receiver clock and word configuration.
Related SpareFaber guides
Drawings, pin maps and manuals
- SICK Stegmann Hiperface Serial Encoders. Overview. AG661 on Siemens 1FT5 and AG100 on Indramat MAC.
- Siemens SIMODRIVE motor configuration manual. Siemens 1FT5 and feedback-option context. Obtain the exact AG661 connector drawing separately.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation