Site visit or send-in evaluation
Provide the complete sensor and motor identification, converter type, drawings and the fault or angle pattern. Photograph the original rotor/stator orientation and connector before removal. Agree packing and intake for the matched components. Use the enquiry form to share the details.
What specialist testing can show
A compatible two-phase resolver-to-digital setup can check the specified excitation and compare both output channels across known shaft positions. Tamagawa documents a VRS mode on its AUA6800 VRDC and supplies evaluation hardware. Mitchell's generic resolver chapter is background. Direct TI-5000JX excitation and TI-3000JX run compatibility for this two-phase VRS model were not verified. Tamagawa VRS converter and evaluation hardware · Mitchell generic resolver background
Tamagawa Doublsyn TSY7020 4X Resolver technical reference
Find your part number
Read TSY7020 and record any OEM suffix or drawing number. This is the smaller Tamagawa Doublsyn with two-phase excitation and two-phase output. Compare the stator and rotor as a matched set. A 4X marking on another resolver alone does not identify its connection method.
| Model | Measuring construction | Mechanical and electrical distinction |
|---|---|---|
| TSY7020 | Doublsyn VRS, 4X, two-phase excitation and two-phase output | Ø52 mm stator, Ø25 mm rotor, 45 Ω ±10% input impedance. |
| TSY7030 | Doublsyn VRS, 4X | Ø101 mm stator, Ø45 mm rotor, 75 Ω ±10% input impedance. |
| TSY1010N1114E227 | Singlsyn 4X stator option | Separate resolver family and parts. Use the Singlsyn drawing and converter selection. |
Tamagawa TSY7020 / TSY7030 specifications · Tamagawa TSY1010 options
Production and end-of-life status
Tamagawa lists TSY7020 and TSY7030 in its Doublsyn lineup. Confirm the lifecycle and exact motor-specific ordering and service options with Tamagawa. Tamagawa current Doublsyn lineup
Specifications
| Parameter | Value / scope |
|---|---|
| Measurement | Variable-reluctance resolver, VRS. Two excitation phases, two output phases and 4 electrical cycles per mechanical turn. |
| Excitation entry | 3 V peak-to-peak at 10 kHz in the Tamagawa table. Use the specified drive waveform, load and exact circuit. |
| Transformation ratio and input impedance | 0.2 ±8% and 45 Ω ±10% for TSY7020 as published. These values are distinct from a DC resistance acceptance limit. |
| Stator / rotor dimensions | Ø52 mm stator outer diameter, −0.04/+0 mm. Ø25 mm rotor outer diameter, +0.018/+0.048 mm. Both 4 mm thick. |
| Operating limits | −40 to +150 °C and 30,000 rpm maximum in the product lineup. Installed motor limits can be lower. |
| Angle accuracy entry | Tamagawa lists ±7.5 arcmin maximum (width). Use the original definition and application conditions. |
Tamagawa exact TSY7020 technical table · Tamagawa Doublsyn technical brochure (PDF)
Mounting and fit
The flat stationary stator and rotating rotor are integrated into the motor. Verify the motor drawing for rotor location and retention, concentricity, axial location and allowable air gap. The outer diameters identify parts and do not establish a running clearance. Preserve the original rotational reference, match the rotor and stator, and protect the coils and faces from impact and debris. Use the motor service procedure for fitting and torques. Tamagawa part dimensions · Doublsyn construction brochure (PDF)
Interface and measuring method
The converter supplies two excitation phases and recovers angle from two outputs in the VRS arrangement. With 4X, one electrical revolution corresponds to 90° of mechanical travel. The raw angle therefore repeats four times per shaft turn. The machine's converter and commissioning method determine how that periodic angle relates to motor poles and full-turn position. Tamagawa distinguishes VRS from other excitation/output patterns in its VRDC documentation. Tamagawa VRDC resolver modes · Doublsyn signal architecture (PDF)
Verified wiring
Use the TSY7020 motor-specific drawing to identify the phases and lead polarity. Tamagawa's public lineup confirms the signal groups below. Obtain the exact sensor and converter pin/colour map before connecting. The AUA6800 IC pinout applies to the converter chip itself.
| Circuit | Role |
|---|---|
| Excitation phase 1 and 2 | The specified two-phase reference drive from the matching converter. |
| Output phase 1 and 2 | Angle-dependent analog return signals into the matching converter inputs. |
| Shield and return arrangement | Follow the motor harness and converter drawings. Verify intentional bonds with the cable disconnected. |
Tamagawa VRS signal description · Separate converter schematic and pin functions
Cables inside the motor and at the machine
The internal resolver lead and machine bulkhead are defined by the installed motor. No standard TSY7020-to-M23 cable order code was verified. Record the exact motor drawing, both connector identifiers, contact mapping and routing. Ask Tamagawa or the motor OEM for the appropriate loom. Preserve the paired conductors and shielding specified by the machine drawings. Tamagawa model identification and technical contact
Fault checks
Secure the load and isolate motor, drive and excitation before disconnecting. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
- Record and inspect. Note where the angle jumps or an alarm occurs. Check rotor retention, stator alignment and connector seating, dirt or damaged leads under isolation.
- Check the detached harness. With the harness isolated from the encoder and receiver at both ends, use resistance mode. First short the meter probes to establish lead resistance. Check each conductor end to end and flex the cable gently at the strain relief. Check between unrelated wires and from signal wires to shield or shell. Expect open only where the drawing calls for isolation. Compare any intentional sense links or shield bonds with the equipment drawing. Keep insulation testers away from connected electronics. With the correct winding schematic, a qualified technician can compare disconnected winding readings with the OEM data or an exact known-good unit.
- Check excitation and return. On an approved fixture, verify both excitation phases at the specified test points. Compare outputs at known angles with appropriate differential equipment and a matched converter. Keep winding impedance at 10 kHz separate from an ohmmeter reading.
- Localize. If excitation is missing, trace the converter and harness. If valid return is present at the sensor and missing at the converter, trace the loom. If the 4X cycle is consistent but machine angle is wrong, check converter mode, mechanical datum, pole mapping and alignment.
Motor and drive applications
Tamagawa describes this redundant resolver for motor position and precision motion control with appropriate VRS conversion. Match the sensor build and converter mode in the actual drive. Tamagawa's redundancy feature does not substitute for machine safety-system validation. Doublsyn design and application · Tamagawa VRS conversion
Angle of alignment and commissioning
Capture the original physical orientation and the machine's approved commutation/angle reference before disturbing the sensor. Establish the relationship between the motor electrical cycle and the resolver's 4X output using the OEM procedure. Revalidate the converter configuration, direction and full system behavior. Any offset or commissioning data belong to the installed converter/drive setup. Use the original motor's verified settings when restoration is approved. Tamagawa multiple-angle specification · Converter mode and setup
Drawings, pin maps and manuals
- Tamagawa Doublsyn TSY7020 / TSY7030 product data. Dimensions, excitation, transformation ratio and model comparison.
- Tamagawa Doublsyn and VRDC technical brochure (PDF). Manufacturer design and conversion reference.
- Tamagawa AUA6800 VRDC. Converter modes, evaluation equipment and separate IC pin data.
- Tamagawa Singlsyn TSY1010. Separate family and 4X comparison.