Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
Use a matched receiver to check position and status and to separate battery-path faults from serial-path faults. Mitchell publishes an entry for TS5700N8401. Verify an exact TS5700N8400 profile and approved lead with Mitchell before using TI-5000JX. Motor running requires a verified drive or tester setup for the complete motor.
Tamagawa SA48 TS5700N8400 Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is TS5700N8400. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| TS5700N8400 | SA48, Ø48 mm housing and 1:10 taper per the catalogue drawing. | 23-bit singleturn, 16-bit multiturn, 5 V absolute serial. |
| TS5667N420 | Related SA48 build. Check its own shaft and mounting tolerances. | 17-bit singleturn and 16-bit multiturn. Confirm drive configuration. |
| TS5702N40 | Compact SA35 open-frame build. | Published 23-bit/16-bit format. Different package and fit. |
| TS5700N8401 | Separate label in the Mitchell feedback-selection article. | Its tester entry does not establish TS5700N8400 compatibility. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Power | 5 V DC ±5% at the encoder. 125 mA typical in normal operation and 65 µA typical on battery in the main catalogue table. |
| Resolution | 23 bits within one turn and 16 bits for turns. Pure binary. |
| Electrical interface | Serial NRZ over a line driver. Catalogue gives a 35–63 µs transfer cycle for this ID. |
| Mechanical and environment | Ø48 mm body, 1:10 taper, 6,000 rpm maximum and −10 to +85 °C. IP40. |
| Attachment drawing | Two M3 holes on Ø30 mm pitch circle, thread depth 6 mm, as shown on catalogue page 51. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
Read the shaft-detail and attachment views together. Match the 1:10 taper, shoulder and seating surfaces to the motor. Check that the encoder is supported during removal and that the lead clears the housing. Use the OEM tightening and extraction method. The catalogue drawing is a fit reference and does not give the motor assembly torque.
Interface and measuring method
The receiver requests position over the serial link and decodes the binary response. The absolute value combines angle within a turn with a stored turn count. Backup battery power supports the latter when main encoder power is absent. A valid angle with an invalid turn count can therefore have a different cause from a complete serial failure.
Verified wiring
Tamagawa catalogue T12-1228N57 page 52 lists the factory lead colors for TS5700N8400. They apply to the encoder leads, while the motor bulkhead requires its own drawing.
| Lead | Function |
|---|---|
| Red | Vcc, main power |
| Black and brown/black | GND, per the published lead table |
| Brown | VB, external battery connection |
| Blue and blue/black | Serial SD differential pair. Follow the polarity marks in the catalogue diagram. |
| Gray | Case ground |
| Shield | NC in the factory lead table. Follow the OEM cable bonding plan. |
Use the exact drive battery specification for chemistry, voltage and replacement sequence. Preserve position data under the OEM procedure.
Cables inside the motor and at the machine
The catalogue drawing shows a factory lead, L ≥ 500 mm. The motor harness and bulkhead wiring are OEM parts. Obtain the exact motor drawing before replacing a cable or tying returns or shields. Record both ends and the battery return routing.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| No response from drive | Verify red-to-documented return under the OEM breakout method, then trace the serial pair and connector. |
| Singleturn position valid but multiturn alarm | Check battery condition and wiring through the drive's documented method. Save position data before removal. |
| Position changes after repair | Check taper seating, coupling and the motor reference. Compare original drive parameters and OEM motor data. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Tamagawa lists SA48 for motor control and robot applications. Identify the actual motor and controller. Match the exact protocol, battery and connector before replacing the encoder or connecting a bench receiver.
Angle of alignment and commissioning
Keep the motor reference and backup data according to the OEM service method. After checking shaft fit, verify direction and the motor's electrical reference with the specified commissioning procedure. Use a supported restore only for valid data from the same motor. Recommission when the original reference is missing.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- Tamagawa rotary encoder catalogue T12-1228N57. Printed pages 51–52 contain the exact drawing, specifications and lead table. Manufacturer catalogue hosted by a distributor.
- Mitchell Generic Tamagawa Feedback Selection. Check the distinct TS5700N8401 entry.