Site visit or send-in evaluation
We check serial position, backup status and the in-motor loom, then assess the encoder fit and retained reference before replacement. Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
The Mitchell index documents the exact device and TI-5659 connection. Confirm the supported TI-5000JX profile and adapter with Mitchell before connecting. An approved SmartAbs receiver can compare within-turn count, turn count and serial response. Verify TI-3000JX support for the exact motor independently.
Tamagawa TS5669N220 TBLi-II SmartAbs Multiturn Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is TS5669N220. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| TS5669N220 | Built-in SmartAbs 35 motor feedback assembly, Ø35 mm class. Compare the exact seating and mounting dimensions in the catalogue. | 17-bit single-turn and 16-bit multiturn. Mitchell lists TI-5659 for the TBLi-II 9-pin AMP application. |
| TS5667N120 | Related built-in model in Tamagawa's selection table. | Check the exact catalogue entry, geometry and electrical assembly before sourcing. |
Production and end-of-life status
Tamagawa Europe lists this exact model. Confirm current orderability or any successor with Tamagawa for the specific motor build.
Specifications
| Parameter | Value and scope |
|---|---|
| Absolute data | 17-bit position per revolution and 16-bit turn data, binary |
| Serial channel | 2.5 Mbit/s bidirectional NRZ with request/response |
| Operating supply | Nominal 5 V DC. Confirm the exact tolerance for the fitted revision because the catalogue specification and lead table show different tolerance wording. |
| Normal operating current | 110 mA typical in the Tamagawa specification |
| Speed and temperature | 6,000 min⁻¹ max mechanically, −10 °C to +85 °C |
| Installation | Built-in open construction. Multiturn data backup uses the specified external battery. |
The table identifies the assembly each value applies to. Main technical PDF.
Mounting and fit
This SmartAbs build mounts inside a motor. Check Tamagawa’s drawing for the motor shaft, locating features and fastening geometry before choosing an assembly. The 35 mm class helps identify the package. Confirm the exact rotor engagement and stator location against the motor service drawing. During isolated work, look for debris, rubbing and a pinched lead.
Interface and measuring method
The receiver requests position and other values over the bidirectional serial pair. The encoder replies with absolute position and turn data. The battery maintains turn information during power loss. Verify the exact drive protocol as well as its serial physical layer and battery circuit.
Verified wiring
The Tamagawa catalogue gives the encoder lead functions below. Use the original connection figure for data polarity. Use the motor or Mitchell cable sheet for the numbered AMP cavities and the correct connector view.
| Lead marking | Function |
|---|---|
| Red / black | Main 5 V supply / return |
| Brown / brown-black | Backup battery supply / return |
| Blue / blue-black | Serial data pair, polarity per catalogue drawing |
Inspect labels and verify continuity with the installed lead disconnected from both ends. Confirm how the OEM separates the supply and battery before connecting.
Cables inside the motor and at the machine
Mitchell lists TI-5659 for TBLi-II TS5669N220 with a 9-pin AMP connection. Its TS5669 family index also lists other plugs. Verify the exact OEM motor, cable part number and mating plug before choosing the adapter. The Tamagawa lead-wire colours apply to the catalogue assembly.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Power present, no response | Confirm the receiver supports the exact protocol and serial data-pair wiring. Check supply at the encoder under the approved test load. |
| Within-turn position works, turn count lost after shutdown | Inspect the external battery circuit and record any backup alarms. Follow the OEM's restore and reference procedure. |
| Serial dropouts change with motor vibration | Inspect the AMP connector, retention, contact contamination and lead routing. |
| Position shift after mechanical work | Check centring, retention and application-specific drive reference before writing any stored values. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Tamagawa lists TS5669N220 for built-in motor feedback. Mitchell names this exact encoder with the TBLi-II fixture. The complete fitted OEM motor code remains to be documented.
Angle of alignment and commissioning
Record the as-found mounting and motor-specific drive parameters. Preserve valid position and battery-backed turn data according to the OEM procedure. Use the motor's documented commutation and reference steps after fitting. Confirm both within-turn position and retained turns before returning the machine to service.
Drawings, pin maps and manuals
- Main technical PDF. Tamagawa catalogue T12-1228N51, pages 45–46, manufacturer-authored copy. See the exact SmartAbs 35 motor mounting and lead table.
- Manufacturer reference. Match the exact order code or the identified motor option.
- Mitchell manufacturer cable index. Tamagawa TI-5659 application and 9-pin AMP description.