Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
Mitchell documents a TS5778 serial bench selection and a separate A/B comparison. Confirm the Kobelco TI-5666 setup, count convention and reset conditions before using TI-5000JX. Confirm the exact robot motor and TI-3000JX run support as a separate check.
Tamagawa TS5778N85 Kobelco Robot Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is TS5778N85. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| TS5778N85 | Kobelco robot feedback per Mitchell. Full axis motor and shaft fit remain application-specific. | TS5778 serial plus A/B. Use the Kobelco reset wiring. |
| TS5778 Shinko application | Related installed assembly with its own connector and fit. | Mitchell distinguishes the reset contact from the Kobelco variant. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Serial position | Mitchell describes 11 bits per turn and a 13-bit turn field for the TS5778 family. |
| Separate motion path | Incremental A and B. Mitchell describes no Z output for TS5778. |
| Test connection | TI-5666 is the 16-pin Molex Kobelco robot lead in the Mitchell index. |
| Scope | Exact OEM supply, pin-view drawing, mounting dimensions and reset conditions require the fitted assembly documentation. |
The table identifies the assembly each value applies to.
Mounting and fit
Before moving the encoder, identify the axis and full servo motor code. Photograph the rotor retention and stator attachment and record the original reference according to the robot maintenance procedure. Compare the actual mating shaft and housing with the replacement drawing before loosening or tightening the assembly.
Interface and measuring method
The receiver uses a serial position word for absolute position and turn information. Separate A/B signals describe motion. A serial read and incremental count can be compared over the same movement with the documented fixture. Check the software count convention against the physical encoder and use the supported profile for this axis.
Verified wiring
Identify the operating supply, return, serial path, A/B, backup and reset on the exact Kobelco wiring drawing. Mitchell distinguishes the reset contact from Shinko. Use its current TI-5666 drawing and the matching OEM contact view for numbered wiring. Preserve the robot reference before changing a backup or reset connection.
Cables inside the motor and at the machine
TI-5666 identifies the Kobelco test fixture with a 16-pin Molex connection. The installed cable between the encoder and robot controller has its own order and may include the backup or reset circuit. Match axis, connector orientation, reset conductor and shield at both ends before measuring continuity.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Serial position alarm while A/B still changes | Compare the serial connection, loaded supply and backup status with the robot diagnostics. |
| Position lost after the battery or cable was disturbed | Follow the Kobelco reference recovery procedure for the specific axis and inspect reset and backup wiring. |
| Both paths fail when the arm moves | Inspect the flexing harness, connectors and strain relief, then isolate and compare continuity end to end. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Mitchell identifies TS5778N85 in Kobelco robots. Record the robot model, axis and full motor code before ordering a replacement or using a cable. The Shinko TS5778 entry describes a different application.
Angle of alignment and commissioning
Preserve the robot’s mastering data and original mechanical reference under the approved OEM procedure before removing feedback. Check whether commissioning needs a reference recovery, motor commutation check or both. A technician should verify the completed robot-axis procedure before motion is permitted.
Drawings, pin maps and manuals
- Mitchell Tamagawa serial encoder guide. TS5778 and TS5778N85 application and reset differences.
- Mitchell cable index PDF. TI-5666, 16-pin Molex Kobelco reference.
The references above describe the verified scope. A direct technical PDF for the exact encoder remains to be confirmed.