Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
Mitchell documents TI-5000JX with the Yaskawa option and TI-5103 for checking the within-turn update. The article distinguishes that from the revolution-count update. Confirm the TI-5017 connector for the installed assembly. Check TI-3000JX support and fixture for the exact motor independently.
Yaskawa UTMAH-B15ASB 15-Bit Legacy Absolute Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is UTMAH-B15ASB. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| UTMAH-B15ASB | Named on the Yaskawa USAREM-02CS2K motor assembly drawing. | 15-bit legacy absolute family with startup update and A/B feedback. |
| UTMAH-B15BSB | Related model named by Mitchell. Confirm the exact motor and mechanical fit. | Compare backup, startup behavior and connection before choosing. |
| UTOP family | Separate Yaskawa feedback designation. | Some configurations have a distinct C-channel or incremental arrangement. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Fitted example | Yaskawa drawing for USAREM-02CS2K names UTMAH-B15ASB. |
| Position per turn | 32,768 counts for the documented 15-bit legacy family. |
| Update | Within-turn startup position is sent as A/B edges. Mitchell describes turn count on the A line at startup. |
| Backup | External battery maintains retained information in the documented legacy system. Use the OEM battery procedure. |
The table identifies the assembly each value applies to. Main technical PDF.
Mounting and fit
Use the Yaskawa motor assembly drawing to identify the fitted encoder housing and lead route. Compare the shaft and retention against the exact installed motor drawing before removal. Record the current motor position and reference under the OEM maintenance procedure.
Interface and measuring method
In this Yaskawa legacy absolute system, the drive receives a position update at startup. Mitchell describes the within-turn value as a burst of A/B quadrature edges and the revolution count as serial data on A. After startup, the drive follows A/B movement. Distinguish this update scheme from a static parallel position word or a later Yaskawa all-serial encoder.
Verified wiring
Use the USAREM motor and receiver wiring for A/B, index, power, signal return and backup. Confirm the connector side and reference for the installed version. Preserve the retained position according to Yaskawa before disconnecting the backup path. Avoid transferring terminal numbering from a newer Sigma feedback connector.
Cables inside the motor and at the machine
Mitchell describes the TI-5017 legacy absolute cable with TI-5103. Match the actual connector and motor to the drawing before using the fixture. The internal motor pigtail and receiver harness are separate OEM assemblies. Obtain their numbers from the full USAREM order and drive.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Startup position is wrong but A/B motion is clean | Check battery status, startup update and original motor reference before changing parameters. |
| No feedback after a long power-off | Verify backup alarms, loaded supply and the OEM recovery sequence. |
| Start torque is wrong following replacement | Check the exact encoder identity and mechanical or electrical commutation reference. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
The OEM bulletin shows UTMAH-B15ASB in a USAREM-02CS2K assembly. Mitchell discusses the broader legacy 15-bit family, including related Allen-Bradley applications. Confirm the original motor and feedback option before mapping a cross-brand lead.
Compare a later serial generation by its complete model. UTSIH-B13 technical guide.
Angle of alignment and commissioning
Capture the original encoder and motor reference and preserve backup before removal. Use the exact motor and drive routine to restore alignment and verify startup and motion. A family-level electrical-angle example needs the actual motor, pole count and approved method before use.
Drawings, pin maps and manuals
- Main technical PDF. Yaskawa AC Servo Drives bulletin, manufacturer-authored mirror. USAREM dimensional drawings identify the fitted encoder.
- Mitchell legacy Yaskawa feedback. Startup count, test scope and TI-5017/TI-5103 arrangement.
- Mitchell Yaskawa motor guide. Legacy feedback variants and separate motor run scope.