What specialist testing can show
TI-5000JX bench. Mitchell documents Sigma-II serial support and identifies UTSAH-B16 as ID 1. Verify lead and fitted connector.
TI-3000JX motor run. Confirm a specific supported run profile and fixture for the fitted Sigma-II motor.
Starting lead. Use the verified Sigma-II encoder fixture for the exact motor and plug.
Yaskawa UTSAH-B16 Sigma-II 16-Bit Absolute Encoder technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| UTSAH-B16 · ID 1 | 16-bit absolute Yaskawa serial encoder in the Mitchell Sigma-II table. |
| UTSAH-B17 | Related 17-bit absolute family. Verify the full label, encoder ID and retention configuration. |
| ID 4 | Separate 16-bit supercapacitor entry in the Mitchell table. Match the fitted motor and retention circuit. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Within-turn position | 16 bits, or 65,536 possible positions per turn, for the documented ID 1. |
| Data path | Yaskawa serial absolute feedback on the matched Sigma-II setup. |
| Retention | Use the exact motor and SERVOPACK manual for battery or retention details and reference recovery. |
Interface and measuring method
The SERVOPACK reads absolute digital position. Check the encoder identification, response and retained reference as distinct pieces of evidence. A retention alarm can arise with a working serial link.
Mounting and fit
Record the complete Sigma-II motor and encoder labels, connector and shaft attachment. Use the matching motor drawing to confirm dimensions and seating before disturbing the installed reference.
Wiring and connector scope
Use the OEM encoder plug and SERVOPACK connection view for supply, serial circuits and any retention lines. Check the fitted harness at both ends and use the approved breakout for a powered check.
Internal motor and machine cables
Select the external encoder cable from the complete motor and drive orders. Source the internal loom from the encoder connector and fitted assembly, using the correct shield and retention layout.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| The reported ID is wrong | Compare the full UTSAH suffix and active tester profile. |
| Position is lost after downtime | Review retention, cable and alarm history before restoring the absolute reference. |
| No serial reply | Check supply, return and the isolated cable path against the fitted connector drawing. |
Angle of alignment and commissioning
Save the absolute reference and current drive settings. Use the matched Yaskawa commissioning and retention instructions before any reset or memory change. Verify direction and machine position after installation.
Motor and drive applications
Sigma-II with verified ID 1
Obtain fitted motor and drive orders, connector drawing, exact fixture and retention procedure.
Related SpareFaber guides
Drawings, pin maps and manuals
- Yaskawa Serial Encoder Identification. Identification table, ID 1
- Yaskawa Sigma-II servo system user manual. Motor wiring, amplifier encoder connection and absolute setup for applicable Sigma-II units.
- Mitchell Yaskawa Serial Encoder Testing. Bench test coverage and diagnostics.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation