Site visit or send-in evaluation
Send the complete Sigma motor and SERVOPACK codes, encoder markings, connector photos and exact alarm. Note whether a backup battery, feedback cable or motor was disconnected before the issue. Use the enquiry form to share the details.
What specialist testing can show
Mitchell documents TI-5000JX testing with the Yaskawa serial Athena support and matching lead. Select the supported 17-bit ABS profile based on the motor and confirmed feedback. Check position, direction and encoder status, and distinguish the tester’s no-battery indication from a motor fault. Mitchell’s TI-3000JX run guide lists the Sigma-II 17-bit absolute serial type as unsupported. Check the current software before planning a run test. Mitchell Yaskawa serial test guide · Mitchell Yaskawa run-test coverage
Yaskawa UTSAH-B17 Absolute Serial Encoder technical reference
Find your part number
Use the full motor order code and read the encoder marking where accessible under the OEM procedure. Mitchell groups UTSAH-B17, UTTAH-B17 and UTSAE-B17 under certain 17-bit ABS feedback codes. The motor suffix can identify the feedback class while more than one assembly remains possible.
| Encoder code | Feedback class | Scope |
|---|---|---|
| UTSAH-B17 | 17-bit absolute serial, battery-backed multiturn | Confirm exact motor and encoder labels. Codes 2 and 5 appear in Mitchell’s table. |
| UTTAH-B17 / UTSAE-B17 | 17-bit absolute serial | Related model codes within the same class. Verify the OEM replacement. |
| UTSAH-B16 | 16-bit absolute serial | Different resolution class. |
| UTTIH-B17 | 17-bit incremental-class serial | Mitchell identifies this as singleturn without battery backup. |
Mitchell Yaskawa model and feedback code lookup
Production and end-of-life status
The Sigma-II manuals remain available. Current production and approved replacement for the exact UTSAH-B17 motor assembly require Yaskawa confirmation. Reviewed 7 November 2026. Mitchell identification table · Yaskawa Sigma-II user manual (PDF)
Specifications
| Parameter | Value / scope |
|---|---|
| Position type | 17-bit absolute serial feedback (131,072 position steps per turn) in the documented feedback class. |
| Turn retention | Battery-backed absolute operation, subject to motor and SERVOPACK configuration. |
| Drive-side encoder supply | Nominal +5 V PG supply on the documented Sigma-II SGDH CN2. |
| Backup | Sigma-II SGDH manual shows 2.8–4.5 V for the documented external backup connection and 3.6 V JZSP-BA01 for the amplifier battery option. Match the installed battery arrangement. |
| Motor and mechanical limits | Use the exact motor order code for speed, encoder fit and environment. Encoder-only mounting limits require the OEM service drawing. |
Yaskawa Sigma-II SGDH wiring and backup (PDF) · Yaskawa Sigma-II motor and cable details (PDF)
Mounting and fit
This feedback device is inside the motor. The rotor must follow the motor shaft and the stationary part must locate on the motor housing. Preserve the original position reference, seating and any shims before disassembly. Inspect the external housing, rear cover and harness for damage. If the fault started after a bearing or encoder change, have the motor-specific seating and alignment checked. The public system manual gives motor outlines and external connectors. Obtain the exact encoder retention, fasteners and torque from Yaskawa for internal work.
Interface and measuring method
The SERVOPACK reads digital position and status on the PS and /PS pair. The backup circuit allows an absolute system to retain the relevant position history with main power off. Treat singleturn count, battery-backed turns and machine reference as separate checks. An encoder can communicate normally while the drive needs its absolute reference re-established.
Verified wiring
| CN2 pins | Function |
|---|---|
| 1 / 2 | PG +5 V / PG 0 V |
| 3 / 4 | BAT+ / BAT− for absolute encoder option |
| 5 / 6 | PS / complementary PS serial signal |
These are the documented SGDH drive-side pins. Use the manual’s CN2 connector view. The motor-end connector and internal PCB differ by motor and harness. Choose the motor-side drawing for the actual order code before building or repairing a cable. Yaskawa chapter 3 CN2 pin table (PDF) · Yaskawa JZSP-CMP00 cable drawing
Cables inside the motor and at the machine
| Part number | Endpoints |
|---|---|
| JZSP-CMP00-03 | 3 m with connectors at SERVOPACK and motor ends. |
| JZSP-CMP03-03 | 3 m with SERVOPACK connector and open conductors at the encoder end. |
| JZSP-CMP10-03 | 3 m flexible cable with connectors at both ends in the Sigma-II table. |
| JZSP-CMP9-2 | Motor-end connector kit in the applicable cable drawing. Confirm exact mating connector. |
Select by exact motor and SERVOPACK. The internal encoder-to-motor connector loom requires the OEM motor drawing. The JZSP-CMP example numbers are external connections. Yaskawa SGMAH/SGMPH cable tables, sections 2.4 and 5.4 (PDF)
Fault checks
Preserve the incoming absolute position. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized. Treat the backup supply as a separate source. Follow the OEM procedure before disconnecting a battery or encoder cable.
- Inspect. Check CN2 latch and pins, motor-end connector, moisture, debris, strain relief and shield. Record whether the alarm followed a cable, motor or bearing change.
- Isolate the loom. With the harness isolated from the encoder and receiver at both ends, use resistance mode. First short the meter probes to establish lead resistance. Check each conductor end to end and flex the cable gently at the strain relief. Check between unrelated wires and from signal wires to shield or shell. Expect open only where the drawing calls for isolation. Compare any intentional sense links or shield bonds with the equipment drawing. Keep insulation testers away from connected electronics. Account for the backup supply and its branch before resistance checks.
- Check PG and backup separately. A qualified technician can fit an approved breakout while off, then verify PG supply across CN2 1/2 and the authorized backup circuit across CN2 3/4 in the specified test state. Compare with the exact drive procedure. Read PS status on a compatible receiver.
- Identify what changed. No communication calls for checking PG supply, the serial pair and the cable. Communication with lost turns calls for checking battery, absolute setup and datum. An error after mechanical repair with good communication calls for checking motor-specific alignment and feedback direction.
Motor and drive applications
Mitchell uses SGMAH-A1A2A21 as an example of the 17-bit ABS feedback code. This identifies the class, with multiple possible encoder model codes. Yaskawa’s Sigma-II manual gives the SGDH drive and motor wiring for the actual order. Read the installed encoder marking before selecting a spare. Mitchell motor code example · Yaskawa Sigma-II application manual (PDF)
Angle of alignment and commissioning
Record the old drive settings and the machine datum. A motor’s commutation alignment is separate from the absolute-turn reset. The Yaskawa Fn008 procedure clears multiturn data on the documented Sigma-II absolute setup, so use it only when the machine commissioning procedure calls for it. Re-establish the machine reference and verify feedback direction and safe travel after the approved setup. The exact motor commutation offset and any restore procedure require the motor service documentation.
Drawings, pin maps and manuals
- Yaskawa Sigma-II SGDH user manual (PDF). Chapter 3 CN2 pinout and absolute encoder setup including Fn008.
- Yaskawa Sigma-II servomotor and cable manual (PDF). Sections 2.4 and 5.4 for the SGMAH/SGMPH cable configurations.
- Yaskawa JZSP-CMP00 official cable drawing. Download the drawing for the motor-side connector.
- Mitchell Yaskawa Serial Encoder Testing. Select the proper profile and distinguish battery status from signal faults.