Site visit or send-in evaluation
Share the feedback label, complete motor or machine order, drive model and alarm. Include both connector faces and note whether the issue followed a cable change, replacement or mechanical work.
What specialist testing can show
TI-5000JX bench. Mitchell identifies the encoder under code 3. Verify the exact harness and Athena selection.
TI-3000JX motor run. Exact motor run setup open
Yaskawa UTTAH-B20 20-Bit Absolute Serial Encoder technical reference
Find your part number
Use the full fitted label. A motor order identifies the assembly and should be recorded separately from an encoder part number.
| ID or order code | Identification and scope |
|---|---|
| UTTAH-B20 | Mitchell encoder ID 3, 20-bit absolute on listed Sigma-II and Sigma-V applications. |
| UTSAH-B17 | Separate 17-bit family with its own identification and software profile. |
Production and end-of-life status
Confirm current orderability and any successor for the exact ID with the manufacturer or motor OEM. The dated documentation identifies the configuration.
Specifications
| Parameter | Verified scope |
|---|---|
| Singleturn resolution | 20 bits, or 1,048,576 positions per revolution. |
| Encoder identification | Mitchell’s serial identification table lists ID 3. |
| Retention and alarms | Use the exact Sigma drive manual for absolute settings, battery status and reference recovery. |
Mounting and fit
Record the complete SGM motor code, full encoder suffix, drive model and retained position. Capture the existing mounting and connector orientation before removing the feedback assembly.
Interface and measuring method
Use the correct Yaskawa serial profile to read the encoder ID, singleturn position, revolution count and status separately. A valid within-turn reading can coexist with a retention or reference problem.
Wiring and connector scope
Use the motor-side and Sigma amplifier diagrams for the actual connector, including the documented feedback supply, communication pair and retention wiring where fitted. Do not infer the motor pin map from the generic Sigma profile.
Cables inside the motor and at the machine
Mitchell’s identification article lists TI-5762 and TI-5764 among Sigma family options. Match the full motor code, connector and adapter before choosing one. The factory loom remains specific to the motor.
Fault checks
Before inspection. Follow the site’s isolation and lockout procedure. Secure any load against movement, allow the specified discharge time and have a qualified technician verify isolation. Check resistance on a disconnected harness at both ends. Use the documented shield and return connections.
| Observation | What to verify |
|---|---|
| Encoder ID reads but revolution count is unreliable | Check the retention system and alarms with the correct Sigma manual. |
| No response after a cable change | Compare the exact connector and serial pair with the installed motor order and test lead. |
| Position is stable but the axis datum is wrong | Review the reference procedure and recorded settings before replacing the encoder. |
Motor and drive applications
Sigma-II and Sigma-V, encoder code 3 Check the exact ID, drive and connector before applying an installation or test procedure.
Start with the motor and encoder nameplates, then separate a communication fault from a loss of absolute position.
Angle of alignment and commissioning
Preserve the prior machine datum, motor order and drive settings. Use the approved Sigma procedure to restore reference after service. Review what a clear or reset operation changes before applying it.
Drawings, pin maps and manuals
- Yaskawa encoder identification. Encoder Code table. Code 3 and applicable Sigma generations.
- Mitchell Yaskawa serial testing. Athena software support and separate position, turn count and error checks.