What specialist testing can show
TI-5000JX bench. Verify the 1,024- or 2,048-line option, plus the fitted commutation signals and reference.
TI-3000JX motor run. Confirm the complete motor order and approved generic incremental run configuration.
Starting lead. Match the complete 15T order and fitted AKM connector to a verified fixture.
EPC Model 15T AKM 1 / 2 Incremental Comcoder technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| EPC Model 15T | Through-bore incremental family. Read the full EPC and motor orders for bore and output. |
| AKM code 1 | 1,024-line singleturn Comcoder in the documented motor option table. |
| AKM code 2 | 2,048-line singleturn Comcoder. Check the correct line count and commutation signals. |
| EPC Model 15H | Related blind-bore construction. Check the mounting and order before substitution. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Line count | 1,024 or 2,048 lines by AKM feedback code. Controller counts depend on decoding. |
| Shaft mounting | Through-bore 15T with configuration-specific bore and flex mount. |
| Electrical | Quadrature plus fitted commutation on the AKM application. EPC’s catalogue has distinct supply and output options. Confirm the actual order. |
Interface and measuring method
Quadrature counts describe movement while the Comcoder’s commutation channels identify motor phase regions. Check the received line count and the commutation state separately.
Mounting and fit
Measure the fitted shaft and check the bore, flex mount and locating position against the EPC and AKM drawings. Record original housing and rotor references before loosening the assembly.
Wiring and connector scope
Use the exact AKM connection code and fitted EPC configuration. Identify incremental, reference and commutation channels by the documented pin view. The general EPC cable table does not establish the OEM bulkhead map.
Internal motor and machine cables
Match the internal encoder link and AKM motor connector to the drive cable order. Keep paired signals and the OEM shield scheme. Verify any spare encoder’s output code and cable exit.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Replacement counts twice or half the expected travel | Check whether the motor order calls for code 1 or 2 and verify edge decoding. |
| Counts work but the motor trips during startup | Check the Comcoder channel wiring and motor phase reference. |
| Position drifts after fitting | Inspect the through-bore seat and the flex mount for movement. |
Angle of alignment and commissioning
Preserve the received commutation reference and count direction. A specialist should verify phase convention and commutation transitions using the exact AKM configuration.
Motor and drive applications
Kollmorgen AKM fitted with EPC 15T
Identify the through-bore 15T and choose the correct line count and commutation path by AKM code.
Related SpareFaber guides
Drawings, pin maps and manuals
- Kollmorgen AKM support. Mitchell-linked AKM Feedback Description, 1 and 2 EPC 15T rows
- EPC Model 15T/H data sheet. Through-bore versus blind-bore drawings, electrical options and encoder wiring.
- Mitchell-linked AKM Feedback Description. Reference for the fitted feedback or motor option.
- Kollmorgen AKM connectivity manual. Comcoder options 1 and 2, with connector choices.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.