What specialist testing can show
TI-5000JX bench. Use SSI after verifying the complete order code, resolution and connection.
TI-3000JX motor run. Specific motor-run setup remains open.
Starting lead. Verify the complete AD34 SSI order and direct breakout.
Hengstler AD34 SSI Compact SSI Absolute Encoder technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| AD34 SC / SD | The manufacturer order table names SC for SSI Gray plus 1 Vpp and SD for SSI binary plus 1 Vpp. |
| AD34 SG / SB | SSI Gray or binary order choices in the stated cable termination grouping. Verify the exact order and drawings. |
| AD34 BC / BV | BiSS options in the same family, with their own receiving profile. Read the actual interface characters. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Resolution choices | The cited family table lists 12–22 singleturn bits, with 12 turn bits on listed multiturn orders. Verify the resolution field. |
| Supply codes | A is 5 V DC and E is 7–30 V DC in the cited order table. Match the exact label before connection. |
| Shaft and stator support | The stated F.0N or U.0N order choices use a 6 mm notched shaft and different spring-tether directions. |
| Connection | Axial or radial 12-contact PCB arrangement and optional mating connector/cable, as shown in the order table. |
Interface and measuring method
SSI uses a clock from the receiver and a serial data word from the encoder. On SC and SD, the separate 1 Vpp channels can be assessed independently. Match the decoding format and bit count to the actual order.
Mounting and fit
Use the AD34 drawing for F or U spring-tether direction, notch geometry and axial or radial connector. Check available clearance and the original shaft reference before swapping a similar housing.
Wiring and connector scope
Use the manufacturer’s two-row connector view and matching interface code. Confirm supply and return, clock and data polarity, and the optional analogue pairs. The drawing shows separate supply-sense connections.
| Contact or circuit | Documented scope |
|---|---|
| 1b and 4b | Supply and 0 V on the documented AD34 connector table. Use the actual A or E code for voltage. |
| 2b/5a and 1a/6b | Clock pair and data pair in the cited connector view. Verify polarity from the original drawing. |
| Analogue pairs | Compare the selected interface characters with the drawing before expecting sine and cosine. |
Internal motor and machine cables
Use the exact cable termination and PCB connector code when identifying the harness. Retain the specified pair and shield arrangement. Use the fitted motor drawing to identify any motor-bulkhead map.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Position jumps at regular points | Check word length and SSI Gray or binary decoding before changing the encoder. |
| Digital angle good, no sine or cosine | Verify whether the full code specifies the analogue channels, then check the fitted pairs. |
| Count intermittent after replacement | Check the tether orientation, shaft fit and the correct axial or radial connector. |
Angle of alignment and commissioning
Preserve the mechanical and machine position reference. Verify Gray or binary configuration, turn mode, direction and any motor-specific commissioning settings.
Motor and drive applications
AD34 SSI installation, confirm exact motor and order
Identify the SSI order and fitted shaft before comparing a BiSS AD34 or a larger AD58.
Related SpareFaber guides
Drawings, pin maps and manuals
- Hengstler Encoders. Absolute Encoders, AD34 listed with BiSS and SSI options
- Unico SSI Serial Encoders. Supplementary reference for the stated model or setup.
- Hengstler AD34 technical data. Manufacturer order key, 6 mm shaft and tether options, PCB pin table and SSI/BiSS interface choices.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.