What specialist testing can show
TI-5000JX bench. Mitchell documents OHE4096 Data Display and the index condition. Use the matching cable and approved bench reference procedure.
TI-3000JX motor run. Match the complete HA motor, amplifier and fixture before powered motor testing.
Starting lead. Exact test lead remains tied to the fitted motor connector and Mitsubishi branch.
Mitsubishi HA-SH103 / OHE4096 Nemicon Serial Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| OHE4096 / SBC-4096 | Mitsubishi designation and Nemicon identification linked by Mitchell. Read the complete label on the fitted encoder. |
| HA-SH103 | Exact motor example in the Mitchell manual. It also cites HA-LH12K1 and HA-LH102C-L1. Confirm the actual fitted assembly. |
| OHE25K-6 | Separate incremental OHE family covered by TCG148. The similar prefix does not establish matching feedback. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Position data | 12-bit serial, providing 4,096 counts per revolution on the named OHE4096. |
| Reference | Mitchell requires the index condition to be satisfied before the position count is absolute. |
| Retention | No multiturn count or backup battery on the documented OHE4096. |
Interface and measuring method
The controller receives serial position, with an index condition for the usable absolute angle. In Mitchell’s Data Display the INDEX state changes when the reference is acquired. Separate a valid response awaiting index from no response or an inconsistent position count.
Mounting and fit
Match the HA-SH103 motor and fitted Nemicon label. Compare shaft engagement, rotor position and encoder seating with the actual rear assembly. Retain the incoming mechanical reference and secure the load before removal.
Wiring and connector scope
Use the exact Mitsubishi motor and amplifier cable diagram. Verify supply, return and serial circuits at the correct connector view. Match the OHE4096 profile and account for index behavior before interpreting a position fault.
Internal motor and machine cables
Identify the factory encoder harness and external cable separately from the complete motor and amplifier orders. Compare both ends and the shield path. Use the corresponding Mitsubishi and Mitchell connector references before replacing the loom.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Position is present but INDEX remains in alarm | Check whether the approved reference test has been performed and confirm the fitted profile. |
| Serial communication is absent | Trace supply and data on the isolated machine harness and confirm the correct motor connector and test fixture. |
| Index is acquired but the motor faults after fitting | Verify the fitted encoder, mechanical seating, drive alarm and commutation reference. |
Angle of alignment and commissioning
Preserve the machine reference and the original encoder position. In the matched specialist fixture verify the index state and the supported electrical-angle display before setting commutation. Use the approved machine procedure for any reference motion.
Motor and drive applications
Mitsubishi HA-SH103 and cited HA-LH examples with OHE4096
Obtain the original connector pin map, A/B amplifier application and internal loom for the specific HA-SH103.
Related SpareFaber guides
Drawings, pin maps and manuals
- Mitsubishi Motors and Serial Encoders. OHE4096, HA-SH103 example and INDEX condition
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.