What specialist testing can show
TI-5000JX bench. Read the reported INC ID and position. Mitchell reports that the encoder can retain turn data which the drive ignores for the INC ID.
TI-3000JX motor run. Mitchell documents J5 INC run support. Confirm the fitted motor, firmware and approved hybrid setup.
Starting lead. TI-5772 on the documented HK-MT hybrid connector.
Mitsubishi Electric HK-MT · CBW/CSW26K INC 26-Bit J5 Serial Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| HK-MT / CBW/CSW26K INC | Mitchell’s name for the incremental-use encoder ID in this motor family. Check the actual fitted label. |
| HK-MT13W | Mitsubishi motor-order example. The motor order and encoder identifier belong in separate fields. |
| CBW/CSW26K ABS | The absolute-use profile in the related J5 family. Confirm the reported type when comparing replacements. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Within-turn data | 26 bits on the documented HK-MT profile. |
| Turn data | Mitchell reports 16 bits of turn count on the tested INC and ABS units. The drive ignores that field for the INC ID. |
| Starting fixture | TI-5772 for the documented HK-MT hybrid connector. |
Interface and measuring method
The feedback travels as serial position data. INC describes the drive’s handling of the profile. Capture the reported type and position before comparing it with a replacement or changing drive settings.
Mounting and fit
Record the HK-MT order, serial number, encoder label and rear housing before removing parts. Mitchell distinguishes built-in CBW and removable CSW types in the wider J5 family. Use the matched Mitsubishi drawing for the fitted version.
Wiring and connector scope
Match the hybrid mating view and follow the exact J5 motor drawing. Identify feedback, power and brake conductors separately before choosing the approved fixture.
Internal motor and machine cables
Compare the complete motor order and drive-side cable designation. Record the factory internal connector separately from the machine cable and TI-5772 test lead.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Position visible but drive rejects the feedback | Compare the INC/ABS identification and original motor order. |
| Unexpected turns after service | Check how the original drive interprets the INC ID. |
| Serial faults under cable movement | Inspect the hybrid lock and isolate-test the feedback conductors on the fitted map. |
Angle of alignment and commissioning
Save the received motor data and reference before replacement. Compare the reported ID, fitted mechanical reference and drive configuration when commissioning.
Motor and drive applications
MELSERVO-J5 HK-MT hybrid connection
Identify when an apparently similar 26-bit J5 encoder requires a different drive configuration.
Related SpareFaber guides
Drawings, pin maps and manuals
- Mitsubishi Melservo J5 Series. Overview, HK-MT INC encoder ID and J5 rotary motor hybrid connection
- Mitsubishi HK-MT13W motor order example. Supplementary reference for the stated model or setup.
- Mitchell Mitsubishi serial connection notes. Compare the actual wiring before selecting a serial fixture. Use the J5 article for the hybrid HK-MT branch.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation