Identify the fitted part
| Guide scope | Schneider Electric BSH SKS36 / SKM36 — Motor application |
|---|---|
| Feedback identity | SKS36 / SKM36 |
| Manufacturer MPN / full suffix | BSH SKS36 / SKM36 is the scoped family/designation. Match every additional character on the fitted label before ordering. |
| OEM service ID / motor order | Not established for a specific fitted unit. Record the full motor label, feedback option and any OEM service ID separately. |
| Interface | Classic HIPERFACE singleturn / multiturn |
| Documented starting connection | TI-5075 on verified 12-contact M23 layout; TI-5094 direct where matched |
| Material distinction | TCG363 is BMH. BSH has its own motor order, connector and installation documentation. |
Specialist testing: connection before conclusion
| TI-5000JX bench scope | Conditional bench scope: Decode BSH feedback code 1/2, 128 sin/cos periods and singleturn/multiturn retention. Exact fixture, supply and drawing must agree before connection. |
|---|---|
| Starting lead / fixture | TI-5075 on verified 12-contact M23 layout; TI-5094 direct where matched |
| Profile / module | Match exact profile, supply, connector and installed software. A named cable is not a complete test procedure. |
| TI-3000JX motor-run scope | No complete motor-run approval for every fitted configuration. Verify motor order, poles, power/brake wiring, phase direction, alignment and installed TI-3000JX profile. |
The admission evidence is Mitchell Product Catalog: named supported motors and feedback — Schneider Electric BSH and SKS/SKM entries; BSH manual encoder section. Verify installed tester software, the actual sensor option and the fixture before connection. A bench result describes the tested configuration; it does not by itself clear the complete drive, brake, machine cable or loaded axis.
Production and replacement status
A manufacturer family or item record is linked below. Its presence is not confirmation that every historical suffix is available. Obtain current status and any proposed successor against the full label; fit, output, connector and motor data must all be checked.
Specifications and interface
| Feedback code 1 | SKS36 singleturn, 128 sin/cos periods per revolution. |
|---|---|
| Feedback code 2 | SKM36 multiturn, 128 sin/cos periods per revolution. |
| Supply / output compatibility | Use the complete fitted label and its wiring drawing. No universal supply, receiver level or excitation is assigned to this family guide. |
| Exact dimensions, torque and pins | Use the scoped drawing or request it through the enquiry. Values from another suffix, connector view or motor revision are not substituted. |
Classic HIPERFACE combines an analogue sine/cosine path with serial identity, position and device data. Readable serial data does not prove healthy analogue signals, and plausible analogue motion does not prove that motor data or a multiturn field is correct. This guide does not extend to HIPERFACE DSL or an Indramat-specific digital interface merely because a label resembles SCS/SCM.
Mechanical fit and retention
Photograph the incoming shaft/coupling position, locating seat, restraint, fasteners and cable exit before removal. Check accessible looseness, contamination, bearing roughness and signs of rubbing after isolation. Identify whether the assembly has its own bearings, a hollow-shaft clamp or a motor-retained sensor; the exact drawing controls that decision. Do not lever against a sensing disc or apply a torque from a similar-looking model.
BSH feedback code 1 identifies SKS36 singleturn and code 2 SKM36 multiturn. Both have 128 sin/cos periods per revolution in the motor manual. BSH connector construction is order-specific; the manual includes Y-TEC and M23 arrangements, which must not be combined into one assumed pin map.
Wiring and connector boundaries
Map five boundaries separately: the sensor plug or PCB, internal motor loom, motor bulkhead, external machine cable and drive/tester end. Record connector gender, keying, contact numbering and whether the drawing shows mating or termination side. The documented Mitchell lead is a starting fixture, not a pin map for a handmade adapter. Keep power, temperature, brake, shield and feedback contacts identified individually.
Starting connection for this guide: TI-5075 on verified 12-contact M23 layout; TI-5094 direct where matched. Use the source below for its named scope. Any unverified pin assignment remains open until the correct drawing is available.
Internal loom and machine cables
The BSH manual distinguishes Y-TEC and M23 motor-side encoder connectors and lists VW3M8220 and VW3M8214 connector kits respectively. These are connector-kit references, not complete internal looms or universal extension cables. Match the full motor connection code, drive end and length when selecting the actual external cable.
Practical fault checks
Isolation and measurement conditions
Secure moving loads, isolate and lock out the relevant energy sources, follow the specified discharge time and have a qualified technician verify isolation before physical inspection or resistance checks. Disconnect both cable ends before continuity/short testing. Powered supply measurements, rotation, retention work and alignment require the approved fixture and procedure.
| Configuration-specific check | BSH feedback code 1 identifies SKS36 singleturn and code 2 SKM36 multiturn. Both have 128 sin/cos periods per revolution in the motor manual. BSH connector construction is order-specific; the manual includes Y-TEC and M23 arrangements, which must not be combined into one assumed pin map. |
|---|---|
| Fault appears when the machine cable moves | With the system isolated and both ends disconnected, inspect flex points, connector engagement and repaired sections. Check end-to-end continuity and unintended shorts against the actual pin map, accounting for intentional shield bonds. |
| No feedback or intermittent loss at the drive | After label and fixture verification, have a qualified technician check the specified supply or excitation through an approved breakout. Compare at the source and load under the OEM procedure; never assume a voltage from the connector shell. |
| Identity reads but the machine still faults | Compare analogue channel quality, serial status and stored motor data as separate evidence. Preserve incoming values; a memory write is not a first diagnostic step. |
Alignment, reference and memory
Record the incoming mechanical datum, direction and motor phase convention before disturbing the sensor. No numerical commutation angle or universal memory image is specified here. A motor-specific alignment requires the exact motor data, supported equipment setup and applicable OEM procedure. Preserve any recoverable offset, identity and parameter data before changes; establish hardware and data compatibility before a specialist transfer or write.
Motor and drive applications
BSH SKS36 / SKM36. TCG363 is BMH. BSH has its own motor order, connector and installation documentation.
A matching maker, connector shell or protocol name is not a complete compatibility chain. Keep motor order → feedback option → internal loom → bulkhead → machine cable → drive configuration recorded separately. No unverified alternate part is offered by this guide.
Drawings, manuals and evidence
- Mitchell Product Catalog: named supported motors and feedback — Schneider Electric BSH and SKS/SKM entries; BSH manual encoder section
- BSH Servo motor manual 0198441113837.04 — Manufacturer technical document; use the named feedback option and exact frame/order. Historical revisions do not prove present availability or fitted-unit interchangeability.
- Manufacturer record / drawing directory — Select the complete fitted order; family identification is not a fit or stock guarantee.
Primary family/application PDF linked; exact fitted order, fixture, internal loom and alignment evidence remain to confirm.
Common questions
What should accompany a BSH SKS36 / SKM36 enquiry?
Send clear photographs of the motor and feedback labels, every suffix/ID, both connector faces, drive model, exact alarm and the circumstances of the fault. Include recent wiring, bearing, encoder or parameter work.
Can the listed Mitchell lead be used as a replacement machine cable?
The lead is documented for the stated test connection. OEM internal looms and machine extensions require their own part numbers, pin maps and mechanical ratings.
Does a successful feedback bench test prove that the motor can be run?
No complete motor-run approval for every fitted configuration. Verify motor order, poles, power/brake wiring, phase direction, alignment and installed TI-3000JX profile. A complete run assessment also checks motor power, brake, protection and mechanical conditions.
When does a site visit or send-in evaluation make sense?
A site visit can help when the fault depends on the drive, installation or moving cable. Send-in evaluation can isolate a removable feedback assembly or supported motor configuration. Agree scope, packing, availability and turnaround with SpareFaber after identification.
Request a scoped service evaluation