What specialist testing can show
TI-5000JX bench. Check 24-bit INC communication and counts. Mitchell distinguishes this branch from earlier INC commutation displays.
TI-3000JX motor run. Verify the exact Sigma-7 motor and TI-3000JX profile before promising a motor run.
Starting lead. Select the Mitchell Sigma-7 lead by the actual fitted motor connector.
Yaskawa UTTSI-B24 24-Bit Incremental Serial Encoder technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| UTTSI-B24 · ID F | Mitchell identifies the 24-bit INC option in the Sigma-7 table. |
| SGM7J encoder code F | Yaskawa’s motor manual names F as 24-bit incremental for the indicated SGM7J configuration. Read the complete motor order. |
| UTTAH-B24RU21 · ID 6 | Mitchell lists a separate 24-bit absolute feedback family. Verify the actual encoder and machine reference. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Within-turn scale | 24 bits, 16,777,216 distinguishable positions in one mechanical revolution for the stated format. |
| Interface | Yaskawa Sigma-7 incremental serial. |
| Bench indicators | Mitchell describes different commutation display behavior for the 24-bit INC branch compared with earlier INC options. |
| Motor connection | Match the actual Sigma-7 motor connector and service drawing. |
Interface and measuring method
The drive receives a digital position and status response. The 24-bit incremental classification is part of the configuration. Verify the exact software selection and appropriate reference behavior.
Mounting and fit
Use the Yaskawa rotary motor outline and fitted encoder drawing. Record the full model, rear assembly position, locating features and connector routing before service.
Wiring and connector scope
Follow the Sigma-7 motor and SERVOPACK encoder connector drawing for the exact order. Confirm the supply and serial pair in that drawing, and use the approved breakout.
Internal motor and machine cables
Use both complete orders to choose the machine encoder cable. Confirm the internal connector and layout before selecting an internal replacement harness.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Wrong profile or ID displayed | Check the fitted encoder and motor code, then select 24-bit INC and verify firmware. |
| No commutation indicator on the bench | Check Mitchell’s 24-bit INC scope before treating the absence of an older-style indicator as a failure. |
| Drive errors with motion | Inspect the full serial harness, plug retention and drive receiver after verifying the direct path. |
Angle of alignment and commissioning
Save drive parameters and the machine reference. Verify rotation sense, reference recovery and any required motor setup using the Yaskawa commissioning procedure.
Motor and drive applications
Yaskawa Σ-7
Use ID F to identify incremental serial and choose the right checks for this 24-bit branch.
Related SpareFaber guides
Drawings, pin maps and manuals
- Yaskawa Serial Encoder Identification. Encoder ID table, F row and Σ-7 connection types
- Yaskawa Serial Encoder Testing. Supplementary reference for the stated model or setup.
- Yaskawa Sigma-7 rotary servomotor product manual. SGM7J type-code field, 24-bit incremental designation and motor connection information.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.