What specialist testing can show
TI-5000JX bench. Use the documented SNS bench sequence and 8720 memory scope, with exact connector and fixture verified.
TI-3000JX motor run. Confirm the spindle and 8720MC drive setup independently. The cited guide scopes the SNS feedback and memory test.
Starting lead. TI-5069 on the verified direct SNS branch with the documented shared serial/index configuration. Module TI-5104 where the verified SNS lead and supply permit it.
Allen-Bradley 8720 Spindle / SNS60 Stegmann Serial and Index Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| 8720SM … S3 | Rockwell code 3, SNS-60 incremental feedback with marker. Match the connector and machine cable to this code. |
| 8720SM … S4 | Rockwell code 4, SNS-60 with the MP-Series connector. Use its own connector view. |
| SNS50 / SNS60 family | Mitchell describes a shared serial/index path in its legacy SNS procedure. Confirm the actual encoder and spindle memory profile. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Analogue position | Rockwell lists 1,024 sinusoidal periods per revolution on the documented SNS-60 branch. |
| Marker | Index and serial operation share a path in the Mitchell SNS setup. Follow the documented mode change. |
| Motor memory | Mitchell documents OEM data on the applicable 8720 spindle feedback. Preserve the original file. |
Interface and measuring method
Use serial mode to identify the encoder and check OEM memory. In the appropriate index mode, verify the marker and incremental count. Compare the actual signal response with the spindle’s configured feedback.
Mounting and fit
Record the fitted SNS60 label, rear assembly, coupling and cable route. Match the spindle motor and correct plug before changing the encoder or connector.
Wiring and connector scope
Use Rockwell’s motor feedback connector drawings for S3 and S4. Verify the connector view and the shared index/data circuit. Use TI-5069 only with the matching direct SNS wiring and the documented adapter arrangement.
Internal motor and machine cables
Select the external 8720SM cable from Rockwell’s table by full feedback code and drive. Confirm the internal encoder connection and wiring before replacing either cable.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Serial works and marker is absent | Check the tester mode and shared index circuit before diagnosing the encoder. |
| No data after cable replacement | Compare S3 versus S4 and the exact Rockwell plug assignments. |
| Drive rejects otherwise valid feedback | Compare the OEM spindle memory, encoder ID and drive configuration. |
Angle of alignment and commissioning
Save the original spindle memory and reference. Verify the encoder marker, direction and actual machine position under the matched spindle procedure.
Motor and drive applications
Allen-Bradley 8720 series spindle
Confirm complete 8720SM order, actual SNS60 suffix, connector code, fitted memory and machine cable.
Related SpareFaber guides
Drawings, pin maps and manuals
- SICK Stegmann Hiperface Serial Encoders. SNS50/60 and Allen-Bradley 8720 spindle application
- Rockwell 8720MC installation manual. 8720SM type codes, SNS-60 S3/S4 connectors and sine/cosine signal reference.
- Mitchell SICK Stegmann SNS Suggested Test Sequence. Legacy SNS serial and marker test workflow.
- Mitchell Allen-Bradley motor manual. 8720 spindle OEM memory and feedback scope.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.