What specialist testing can show
TI-5000JX bench. TI-5661 is the documented starting lead. Confirm the exact interface, pin view, supply and supported tester profile from the fitted ID before connecting.
TI-3000JX motor run. Motor-run setup remains open for the fitted axis.
Starting lead. TI-5661 on the listed 17-contact M23 FANUC 01 branch.
HEIDENHAIN RCN 220 / RCN 223 FANUC Test Connection Guide technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| RCN 220 | Named in Mitchell’s TI-5661 index. Obtain the complete ID and OEM interface before connecting. |
| RCN 223 | Also named in the TI-5661 index. The base number alone leaves the suffix and order unresolved. |
| RCN 223 F | HEIDENHAIN’s catalogue lists FANUC 02 and 23-bit position for this order. |
| RCN 223 M | HEIDENHAIN lists a Mitsubishi serial interface. Confirm that suffix before a cable or replacement decision. |
Production and end-of-life status
The linked HEIDENHAIN catalogue documents earlier RCN 200 orders. Exact orderability and a qualified replacement remain open until HEIDENHAIN identifies the full part.
Specifications
| Parameter | Verified scope |
|---|---|
| Mitchell cable branch | TI-5661, 17-contact M23, labelled FANUC 01 in the cable index. |
| OEM RCN 223 F example | 23 bits per turn, 8,388,608 positions per revolution. These figures apply to the catalogue FANUC 02 order. |
| RCN 200 catalogue construction | Integral bearing, integrated stator coupling and 20 mm hollow through shaft on the illustrated order family. Use the fitted ID drawing for mating dimensions. |
Interface and measuring method
An absolute angle encoder transmits angular position to the axis control. Serial interface, position resolution and plug format are separate checks. Record the control and interface before assuming a matching M23 plug carries the expected data.
Mounting and fit
On the RCN 200 catalogue drawing, the through shaft seats on the machine shaft and the housing location is held by the stator coupling. Compare the encoder ID, pilot and shaft tolerances, axial travel and orientation mark with the exact drawing. Preserve the axis reference and cable exit before loosening the assembly.
Wiring and connector scope
Mitchell documents the 17-contact M23 test-connection class. Match the order-specific power, return and serial pairs to the encoder and controller drawings. The index description leaves pin assignments and supply open for the actual part.
Internal motor and machine cables
Record the factory encoder pigtail and the axis extension separately. On a rotary table, inspect both connector halves and the cable route through the moving joint. Select the OEM extension after confirming interface and full order.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Serial alarm immediately after replacement | Compare the interface order and F or M suffix against the drive and the original label. |
| Position drops only in a travel window | Check cable bending and connector strain near that window before removing the ring encoder. |
| Stable data with a shifted angular reference | Compare the housing reference, shaft seating and machine datum recorded before removal. |
Angle of alignment and commissioning
Record the axis datum, direction and measured position at a known mechanical point before removal. Verify zero and repeatability after fitting against the machine builder’s procedure. Treat a motor Pulsecoder alignment routine as a separate application.
Motor and drive applications
Rotary axis with the named RCN and FANUC 01 order
Use the encoder ID and FANUC 01 marking to select the correct angle-encoder drawing and cable.
Related SpareFaber guides
Drawings, pin maps and manuals
- Mitchell Test Cable Index by Manufacturer. HEIDENHAIN section, TI-5661 RCN220/223 FANUC 01 row
- Pin Configurations and Reference Information. Supplementary reference for the stated model or setup.
- HEIDENHAIN angle encoders with integral bearing. RCN 200 drawing and RCN 223 F/M interface comparison on printed pages 24–25. Scope these values to the listed OEM orders.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation