Encoder and resolver technical library

KEB DL4 SG-L6 LC Classic HIPERFACE Singleturn / Multiturn Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment

KEB DL4 SG-L6 LC | Classic HIPERFACE | ST + MT | Installation, Repair, Alignment workshop illustration

KEB DL4 SG-L6 LC · Classic HIPERFACE

SpareFaber offers UAE site visits and send-in evaluation for the KEB DL4 SG-L6 LC. Use this guide to identify the fitted feedback, prepare the right cable and drawing, and investigate faults before ordering parts or starting alignment.

Request a UAE site visit or bench evaluation

Find your part number

Compare the motor nameplate, complete part number and fitted feedback label. SRS50/SRM50 feedback for the liquid-cooled SG-L6 outline. Keep raw encoder data and drive interpolated resolution separate.

What to identify Catalogue reference
Frame and length SG / L6
Cooling code LC, circulating liquid
Electrical family Nominal 400 V DL4, eight motor poles
Feedback SRS50 single-turn or SRM50 multiturn

Include any special suffixes and clear photos of the mating connectors and the feedback mount.

What specialist testing can establish

Read HIPERFACE identity and position, then assess the analogue sine and cosine paths for the exact SRS50 or SRM50 order. Confirm communication at the fitted motor connector and separate encoder faults from harness or supply faults.

SpareFaber can assess a site visit or a send-in evaluation. Direct encoder checks and complete motor run tests require confirmed hardware and independent setup decisions.

Reference specifications

Parameter Catalogue value Scope
Rated torque (N·m) 510 at 1,000 rpm, 480 at 1,800 rpm, 445 at 2,600 rpm KEB DL4 table for this stack and cooling code
Stall torque reference (N·m) 555 Keep the actual speed/winding row and cooling conditions
Catalogue motor mass (kg) 147 Check lifting points and the fitted brake and terminal box weight
Catalogue coolant flow (L/min) 10 Confirm coolant, pressure drop and site circuit from the DL4 manual

Mechanical fit

Use the L6 liquid-cooled outline, with 300 mm flange outside diameter, 250 mm pilot and 55 k6 × 110 mm shaft as catalogue references. Check brake length, port access, cooler routing and lifting clearances on the complete order.

Check the fitted part’s complete drawing before choosing a substitute. Compare shaft or bore, mounting dimensions, locating features and harness clearance.

Wiring and connector scope

Use the specific DL4 HIPERFACE drawing for supply, return, serial pair and separate analogue sine/cosine pairs. Write down the actual contact view and feedback suffix.

Identify the connector face and drawing revision. Approved service personnel should isolate power, secure the load and verify the relevant wiring before any powered checks.

Internal wiring and machine cables

Confirm the complete feedback cable part number at both ends. Document motor-side connector or terminal-box arrangement, receiver, shield termination and cable length. Check cooling, brake and thermal sensor conductors against their own diagrams.

Send clear photos of both mating connectors and the cable label. Note where the harness flexes and whether a connector, cable or drive was recently replaced.

Fault checks

Observed symptom What to check
Feedback fault with stable motor temperature Check the fitted feedback code, harness and connection diagram first.
Temperature rises after coolant service Compare actual coolant flow and type against the LC drawing and nominal duty.
Position changes after encoder or resolver work Compare saved reference, rotation and the exact sensor holder.

Alignment and commissioning

Record readable encoder identity, position, turn counter where present, and the incoming motor reference before work. Confirm fitted direction and commutation with the approved KEB motor/drive procedure.

Compare readable identification, position and turn scope to the exact feedback information, then verify the axis reference on the matching system.

Production and availability

Request availability against the complete DL4 SG-L6 LC order, serial number and feedback label. SpareFaber offers installation, fault diagnosis and alignment assessment. Ask separately for part supply or replacement options.

Motor and drive applications

KEB COMBIVERT F6/S6 as documented for the selected motor and drive rating. Supply both labels and the installed drive parameter set.

Send the motor order, drive nameplate, feedback label and fault history to check the service scope and assembly revision.

Drawings and manuals

Common questions

What should I send for an evaluation?

Send the complete DL4 SG-L6 LC order, feedback label, connectors at both ends, drive order and the original fault or alarm.

Can I match the feedback from the motor frame?

Use the order information above, then compare the actual feedback label, signals, drawings and reference procedure.

Can you check the motor at our site?

Request a UAE site visit or bench evaluation. Share the location, equipment labels and what happened before the fault so the service team can confirm the appropriate scope.

Request service

Send the full motor and encoder IDs, drive model, connector pictures and fault history with your service enquiry. Include your location for an on-site visit.

Enquire about this encoder or resolver

Tell us what needs checking. We’ll review the details and confirm the scope and quotation before booking chargeable work.

What do you need help with?