Encoder and resolver technical library
KEB DL4 SG-L6 LC Resolver Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment
KEB DL4 SG-L6 LC · Resolver
SpareFaber offers UAE site visits and send-in evaluation for the KEB DL4 SG-L6 LC. Use this guide to identify the fitted feedback, prepare the right cable and drawing, and investigate faults before ordering parts or starting alignment.
Request a UAE site visit or bench evaluation
Find your part number
Compare the motor nameplate, complete part number and fitted feedback label. Rated speed rows 1,000, 1,800 and 2,600 rpm. 555 N·m stall. Match the L6 cooling flow and shaft/outline.
| What to identify | Catalogue reference |
|---|---|
| Frame and length | SG / L6 |
| Cooling code | LC, circulating liquid |
| Electrical family | Nominal 400 V DL4, eight motor poles |
| Feedback | Standard resolver |
Include any special suffixes and clear photos of the mating connectors and the feedback mount.
What specialist testing can establish
Compare resolver excitation and the two secondary signals using the fitted connection diagram. Check repeatability and polarity on an appropriate bench setup. Confirm the resolver type and signal levels from the fitted order before selecting a test profile.
SpareFaber can assess a site visit or a send-in evaluation. Direct encoder checks and complete motor run tests require confirmed hardware and independent setup decisions.
Reference specifications
| Parameter | Catalogue value | Scope |
|---|---|---|
| Rated torque (N·m) | 510 at 1,000 rpm, 480 at 1,800 rpm, 445 at 2,600 rpm | KEB DL4 table for this stack and cooling code |
| Stall torque reference (N·m) | 555 | Keep the actual speed/winding row and cooling conditions |
| Catalogue motor mass (kg) | 147 | Check lifting points and the fitted brake and terminal box weight |
| Catalogue coolant flow (L/min) | 10 | Confirm coolant, pressure drop and site circuit from the DL4 manual |
Mechanical fit
Use the L6 liquid-cooled outline, with 300 mm flange outside diameter, 250 mm pilot and 55 k6 × 110 mm shaft as catalogue references. Check brake length, port access, cooler routing and lifting clearances on the complete order.
Check the fitted part’s complete drawing before choosing a substitute. Compare shaft or bore, mounting dimensions, locating features and harness clearance.
Wiring and connector scope
Confirm the excitation pair and sine and cosine secondary pairs from the KEB wiring drawing. Document signal polarity, screen routing and actual resolver cycles per revolution for this assembly.
Identify the connector face and drawing revision. Approved service personnel should isolate power, secure the load and verify the relevant wiring before any powered checks.
Internal wiring and machine cables
Confirm the complete feedback cable part number at both ends. Document motor-side connector or terminal-box arrangement, receiver, shield termination and cable length. Check cooling, brake and thermal sensor conductors against their own diagrams.
Send clear photos of both mating connectors and the cable label. Note where the harness flexes and whether a connector, cable or drive was recently replaced.
Fault checks
| Observed symptom | What to check |
|---|---|
| Feedback fault with stable motor temperature | Check the fitted feedback code, harness and connection diagram first. |
| Temperature rises after coolant service | Compare actual coolant flow and type against the LC drawing and nominal duty. |
| Position changes after encoder or resolver work | Compare saved reference, rotation and the exact sensor holder. |
Alignment and commissioning
Record the original resolver orientation, signal polarity and repeated angle under the qualified bench setup. After service, validate the motor/drive reference using the KEB commissioning method.
Check that the cyclic resolver position agrees across slow, controlled repeat observations. Verify original polarity and scaling.
Production and availability
Request availability against the complete DL4 SG-L6 LC order, serial number and feedback label. SpareFaber offers installation, fault diagnosis and alignment assessment. Ask separately for part supply or replacement options.
Motor and drive applications
KEB COMBIVERT F6/S6 as documented for the selected motor and drive rating. Supply both labels and the installed drive parameter set.
Send the motor order, drive nameplate, feedback label and fault history to check the service scope and assembly revision.
Drawings and manuals
- KEB DL4 High Torque Series catalogue. Standard feedback options, part number key and air / liquid cooled technical tables.
- KEB DL4 instructions for use
Common questions
What should I send for an evaluation?
Send the complete DL4 SG-L6 LC order, feedback label, connectors at both ends, drive order and the original fault or alarm.
Can I match the feedback from the motor frame?
Use the order information above, then compare the actual feedback label, signals, drawings and reference procedure.
Can you check the motor at our site?
Request a UAE site visit or bench evaluation. Share the location, equipment labels and what happened before the fault so the service team can confirm the appropriate scope.
Request service
Send the full motor and encoder IDs, drive model, connector pictures and fault history with your service enquiry. Include your location for an on-site visit.
Enquire about this encoder or resolver