Encoder and resolver technical library

Kollmorgen AKM2G-74 Resolver R- Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment

Kollmorgen AKM2G-74 | Resolver R- | Resolver | Installation, Repair, Alignment workshop illustration

Kollmorgen AKM2G-74 · Resolver R-

SpareFaber offers UAE site visits and send-in evaluation for the Kollmorgen AKM2G-74. Use this guide to identify the fitted feedback, prepare the right cable and drawing, and investigate faults before ordering parts or starting alignment.

Request a UAE site visit or bench evaluation

Find your part number

Compare the motor nameplate, complete part number and fitted feedback label. Frame 7, P/Q/R windings. 100 K base Tcs reference. Use size-7 resolver matrix and correct connector/current branch.

What to identify Catalogue reference
Exact motor base AKM2G-74
Frame and windings Frame 7, 192 mm square. P / Q / R windings.
Feedback code R-
Connector route Ad or C at ≤20 A, H above 20 A per revision and fitted order

Include any special suffixes and clear photos of the mating connectors and the feedback mount.

What specialist testing can establish

Verify the R- motor-side route with the size-7 matrix. Test cyclic resolver angle only through an identified compatible excitation source and correctly documented fixture.

SpareFaber can assess a site visit or a send-in evaluation. Direct encoder checks and complete motor run tests require confirmed hardware and independent setup decisions.

Reference specifications

Parameter Catalogue value Scope
Base continuous stall reference 71.3–72.2 N·m at 100 K winding rise Select the exact 60 K/100 K winding, mounting heat sink and installed option ratings
R- feedback Inductive resolver Confirm actual excitation, secondary connections and resolver speed

Mechanical fit

Use the AKM2G-74 frame 7 drawing and the P / Q / R winding columns. Check mount, shaft, brake added length and connector height for R-.

Check the fitted part’s complete drawing before choosing a substitute. Compare shaft or bore, mounting dimensions, locating features and harness clearance.

Wiring and connector scope

Confirm Ad or C at ≤20 A, H above 20 A per revision and fitted order in the Kollmorgen size-7 connector matrix for the fitted motor and drive. Read the exact connection drawing for R- and trace the documented contact and shield arrangements.

Identify the connector face and drawing revision. Approved service personnel should isolate power, secure the load and verify the relevant wiring before any powered checks.

Internal wiring and machine cables

Match the complete AKM2G winding, current and connector code to the drive and cable combination. Verify whether the route uses hybrid or separate connectors, and the cable part number at both ends.

Send clear photos of both mating connectors and the cable label. Note where the harness flexes and whether a connector, cable or drive was recently replaced.

Fault checks

Observed symptom What to check
Feedback may be correct but the drive rejects the motor Confirm current branch, full string and drive feedback compatibility.
Intermittent feedback after cable replacement Compare actual connector and lead references with the size-7 table.
Position shift after mounting Verify fitted housing and reference using the exact frame drawing.

Alignment and commissioning

Preserve the incoming motor identity and electrical reference. Match correct mechanical position and direction to the fitted drive's commissioning reference. Record readable turns and any required re-reference procedure for the absolute option.

Check that the cyclic resolver position agrees across slow, controlled repeat observations. Verify original polarity and scaling.

Production and availability

Request availability against the complete AKM2G-74 order, serial number and feedback label. SpareFaber offers installation, fault diagnosis and alignment assessment. Ask separately for part supply or replacement options.

Motor and drive applications

Kollmorgen AKD/AKD2G or another documented matching drive with exact feedback support and current rating. Verify the motor order code and installed cable.

Send the motor order, drive nameplate, feedback label and fault history to check the service scope and assembly revision.

Drawings and manuals

Common questions

What should I send for an evaluation?

Send the complete AKM2G-74 order, feedback label, connectors at both ends, drive order and the original fault or alarm.

Can I match the feedback from the motor frame?

Use the order information above, then compare the actual feedback label, signals, drawings and reference procedure.

Can you check the motor at our site?

Request a UAE site visit or bench evaluation. Share the location, equipment labels and what happened before the fault so the service team can confirm the appropriate scope.

Request service

Send the full motor and encoder IDs, drive model, connector pictures and fault history with your service enquiry. Include your location for an on-site visit.

Enquire about this encoder or resolver

Tell us what needs checking. We’ll review the details and confirm the scope and quotation before booking chargeable work.

What do you need help with?