What specialist testing can show
TI-5000JX bench. Read the option and plug first, then check the documented C/D incremental signals.
TI-3000JX motor run. Encoder bench diagnosis only in the documented Mitchell scope for these asynchronous spindles.
Starting lead. TI-5613 for the documented 9-contact M23. TI-5022 for the documented 12-contact M23.
Bosch Rexroth Indramat 2AD C / D Incremental Spindle Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| 2AD C or D | Incremental spindle branch in Mitchell’s 2AD options table. Confirm the type-code position and complete motor order. |
| 9-contact M23 | Use Mitchell Image 3 and the TI-5613 reference for this plug. |
| 12-contact M23 | Use Mitchell Image 4 and TI-5022 for this plug. |
| 2AD 6, 7, 8 or 9 | These option codes have a different BRI_I2C test path. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Machine class | Air-cooled asynchronous 2AD spindle motor. |
| Feedback type | Incremental channels with reference on the illustrated C/D connection. Identify the exact fitted encoder to establish line count and signal level. |
| Bench selection | Athena Generic Incremental with the cable matched to the motor plug. |
Interface and measuring method
The drive derives relative spindle movement and direction from the two incremental channels. The reference channel is a separate part of the diagnosis. A clean A/B count with a missing reference can still cause an orientation fault.
Mounting and fit
Use the 2AD frame and rear encoder assembly drawing. Record the locating seat, actual ROD or fitted encoder label and drive connection before disturbing the assembly. Check for bearing play and coupling damage where the OEM procedure permits access.
Wiring and connector scope
Follow Mitchell Images 3 and 4 for the exact 9- or 12-contact view. Confirm the encoder output level on its own label or drawing before applying a supply. Keep the spindle power, fan and thermal circuits separate.
Internal motor and machine cables
Identify the internal feedback lead from the spindle assembly and the drive cable from the actual drive and plug. TI-5613 and TI-5022 are test fixtures. They identify the supported bench connections.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Spindle turns but orientation fails | Verify reference activity and the machine’s orientation setting independently of the A/B tracks. |
| No count on the test fixture | Check the actual contact count, connector view and both signal paths against Mitchell’s drawing. |
| Counts change when moving the loom | Inspect strain at the rear cover and run isolated cable checks before condemning the encoder. |
Angle of alignment and commissioning
Mitchell describes no feedback commutation alignment requirement for the asynchronous 2AD. After mechanical work, confirm direction, reference integrity and any machine spindle orientation procedure on the installed drive.
Motor and drive applications
Indramat 2AD asynchronous spindle, C or D option
Distinguish the C/D connectors and check feedback on the spindle without applying the Option 6 I²C setup.
Related SpareFaber guides
Drawings, pin maps and manuals
- Indramat 2AD Asynchronous Motors. Feedback Connections, C and D, Images 3 and 4
- Mitchell Generic Incremental Quadrature Pulse Encoders. Supplementary reference for the stated model or setup.
- Indramat 2AD project planning manual. OEM-authored legacy frame, type code and installation reference.
- TI-5613 fixture. Nine-contact M23 bench fixture.
- TI-5022 fixture. Twelve-contact M23 bench fixture.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.