What specialist testing can show
TI-5000JX bench. Match AS1H and the connector form. Mitchell documents SEW memory and alignment for the applicable HIPERFACE setup.
TI-3000JX motor run. Exact motor-run setup open.
Starting lead. TI-5650 for the documented 12-pin M23 HIPERFACE branch Module TI-5104.
SEW-EURODRIVE CFM AS1H HIPERFACE Multiturn Motor Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| AS1H · 0199 442 5 | SEW catalogue identifier for the HIPERFACE multiturn option. Confirm the motor order and fitted cable. |
| ES1H · 0199 443 3 | Singleturn HIPERFACE option. Check turn retention requirements before considering a substitute. |
| CFM resolver option | Different excitation and return paths. Identify it from the complete motor order and wiring. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Incremental tracks | SEW lists 1 Vpp sine/cosine with 1,024 cycles per revolution for AS1H/ES1H. |
| Singleturn digital resolution | SEW lists 32,768 increments per revolution, 15 bits, for the catalogue options. |
| AS1H multiturn resolution | 4,096 revolutions, 12 bits, in the SEW AS1H catalogue. |
| Motor connection | The cited connection branch uses a 12-contact round signal connector. Some CFM configurations use a terminal box. |
Interface and measuring method
The drive reads absolute position over HIPERFACE and tracks motion using the analog sine/cosine pair. A valid singleturn read does not prove that the correct turn count and motor memory are available.
Mounting and fit
Read the CFM frame, brake and feedback option from the motor order. Use the OEM outline for that frame and retain the original encoder seating, harness route and clocking before removal.
Wiring and connector scope
Open section 10.7.2 of the DFS/CFM operating instructions for ES1H/AS1H and select the correct connector view. Use the terminal box instructions if fitted. Confirm the supply, serial pair and analog tracks separately.
Internal motor and machine cables
TI-5650 with TI-5104 is the documented 12-contact tester arrangement. SEW lists the machine-side and hybrid cable variants in the applicable motor catalogue. Match the motor and drive connector and the cable type before ordering.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Drive identifies feedback but positions wander | Check the analog pair amplitudes and connector contact quality using the verified fixture. Inspect mounting. |
| Within-turn position is correct but turns are wrong | Verify AS1H versus ES1H and the drive’s referencing and retention settings. |
| No response after a motor or cable swap | Compare HIPERFACE versus resolver and the plug versus terminal box drawing before changing parts. |
Angle of alignment and commissioning
Mitchell describes standard alignment on common SEW configurations and a separate SEW memory read/program workflow. Verify the exact CFM reference and fitted option. Save the original motor data before replacement.
Motor and drive applications
SEW CFM servomotors
Verify the motor feedback option and M23 versus terminal-box wiring. Keep the resolver branch separate.
Related SpareFaber guides
Drawings, pin maps and manuals
- SEW Servo Motors. CFM Series and CFM Feedback Connections. AS1H/ES1H, signal plug and terminal box.
- SEW CFM motor catalogue, AS1H/ES1H table. Model IDs and feedback specification table.
- SEW DFS/CFM operating instructions. Wiring and fitting. Use section 10.7.2 for the ES1H/AS1H signal plug.
- SEW DFS/CFM cable catalogue. Hybrid cable selections and connector views.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation