SpareFaber offers UAE site visits and send-in evaluation for the Baumüller DS2-100LO54W. Use this guide to identify the fitted feedback, prepare the right cable and drawing, and investigate faults before ordering parts or starting alignment.

Request a UAE site visit or bench evaluation

Find your part number

Compare the motor nameplate, complete part number and fitted feedback label. Liquid-cooled DS2-100 LO stack. M0 from OEM continuous rating table. Use resolver A and the actual DS2-100 holder and drawing.

What to identify Catalogue reference
Motor base DS2-100LO54W
Cooling Liquid cooled, IP54 catalogue design
Feedback code A, standard resolver

Include any special suffixes and clear photos of the mating connectors and the feedback mount.

What specialist testing can establish

Verify the standard A resolver identity from the DS2 order. Use a suitable verified resolver fixture and compare cyclic reference and secondaries with the actual waveform and supported excitation.

SpareFaber can assess a site visit or a send-in evaluation. Direct encoder checks and complete motor run tests require confirmed hardware and independent setup decisions.

Reference specifications

Parameter Catalogue value Scope
Stall torque reference 130 N·m M0 for the LO stack. Retain actual winding, cooler and drive conditions.
Resolver A One pole pair, catalogue excitation 5 kHz / 7 V RMS Reference condition from OEM. Confirm actual fitted order and intended test hardware.
Signal type Excited resolver with sine and cosine secondary output Identify winding pairs and polarity with the correct diagram

Mechanical fit

Use the liquid-cooled DS2-100 LO stack drawing. Compare DS2/DS2+ winding speed, mount, shaft, brake length, terminal box and fitted feedback adapter. Keep the coolant connection accessible.

Check the fitted part’s complete drawing before choosing a substitute. Compare shaft or bore, mounting dimensions, locating features and harness clearance.

Wiring and connector scope

Trace excitation, sine and cosine secondary pairs from the standard resolver A diagram and motor bulkhead drawing. Check direction and screen against the exact order.

Identify the connector face and drawing revision. Approved service personnel should isolate power, secure the load and verify the relevant wiring before any powered checks.

Internal wiring and machine cables

Use the selected DS2-100 drawing to identify terminal box and feedback route on the actual motor. Verify cable construction and receiver, including the cooler, thermal and possible brake circuits.

Send clear photos of both mating connectors and the cable label. Note where the harness flexes and whether a connector, cable or drive was recently replaced.

Fault checks

Observed symptom What to check
Intermittent feedback on a hot motor Correlate cooler and winding/temperature records with encoder supply or resolver signals.
Mechanically similar donor assembly Compare exact LO stack, revision and feedback holder.
Servo trips after assembly Verify original reference, sensor signal and motor data for the fitted order.

Alignment and commissioning

Record original sensor orientation, fitted code and drive identification. Compare the reference before and after service with the documented drive process and preserve the machine origin.

Check that the cyclic resolver position agrees across slow, controlled repeat observations. Verify original polarity and scaling.

Production and availability

Request availability against the complete DS2-100LO54W order, serial number and feedback label. SpareFaber offers installation, fault diagnosis and alignment assessment. Ask separately for part supply or replacement options.

Motor and drive applications

Baumüller drive application with the exact DS2/DS2+ order, actual cooling configuration and feedback option.

Send the motor order, drive nameplate, feedback label and fault history to check the service scope and assembly revision.

Drawings and manuals

Common questions

What should I send for an evaluation?

Send the complete DS2-100LO54W order, feedback label, connectors at both ends, drive order and the original fault or alarm.

Can I match the feedback from the motor frame?

Use the order information above, then compare the actual feedback label, signals, drawings and reference procedure.

Can you check the motor at our site?

Request a UAE site visit or bench evaluation. Share the location, equipment labels and what happened before the fault so the service team can confirm the appropriate scope.

Request service

Send the full motor and encoder IDs, drive model, connector pictures and fault history with your service enquiry. Include your location for an on-site visit.

Enquire about this encoder or resolver

Tell us what needs checking. We’ll review the details and confirm the scope and quotation before booking chargeable work.

What do you need help with?