Encoder and resolver technical library
Control Techniques Unimotor hd 190UDC / 190EDC Resolver AE Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment
Control Techniques Unimotor hd 190UDC / 190EDC · Resolver AE
SpareFaber offers UAE site visits and send-in evaluation for the Control Techniques Unimotor hd 190UDC / 190EDC. Use this guide to identify the fitted feedback, prepare the right cable and drawing, and investigate faults before ordering parts or starting alignment.
Request a UAE site visit or bench evaluation
Find your part number
Compare the motor nameplate, complete part number and fitted feedback label. Group the 460 V UD and 230 V ED orders for the same 190 mm stack. Use the exact AE resolver, connectors and drive match. Do not reuse Unimotor fm tables.
| What to identify | Catalogue reference |
|---|---|
| Physical stack | 190 mm, length C |
| 230 V example | 190EDC… |
| 460 V example | 190UDC… |
| Feedback order | AE resolver |
Include any special suffixes and clear photos of the mating connectors and the feedback mount.
What specialist testing can establish
Establish the exact AE resolver and interface before testing. Compare reference signal, angle repeatability and sine/cosine symmetry with the correctly identified excitation and lead.
SpareFaber can assess a site visit or a send-in evaluation. Direct encoder checks and complete motor run tests require confirmed hardware and independent setup decisions.
Reference specifications
| Parameter | Catalogue value | Scope |
|---|---|---|
| Continuous stall torque | 52 N·m | 190 mm Unimotor hd data for the proposed stack |
| Voltage variants | ED 230 V and UD 460 V | Identify winding and matching drive separately |
Mechanical fit
Use the Unimotor hd 190 mm outline for the C stack. Record flange, shaft/key, brake clearance and connector arrangement from the complete order. Review voltage/winding type independently of mechanical fit.
Check the fitted part’s complete drawing before choosing a substitute. Compare shaft or bore, mounting dimensions, locating features and harness clearance.
Wiring and connector scope
Trace resolver excitation and secondaries using the actual motor diagram. Verify the connector/order, shield route and resolver cycles per turn before assessing signal alignment.
Identify the connector face and drawing revision. Approved service personnel should isolate power, secure the load and verify the relevant wiring before any powered checks.
Internal wiring and machine cables
Read the Unimotor hd 190 connector selection against the fitted supply, brake and encoder choices. Compare the two ends of both power and feedback cables with the drive and motor drawing.
Send clear photos of both mating connectors and the cable label. Note where the harness flexes and whether a connector, cable or drive was recently replaced.
Fault checks
| Observed symptom | What to check |
|---|---|
| Motor type selected but feedback is missing | Check 190ED/190UD wiring, the FB/EB or AE field, and the installed input. |
| Alignment fault after repair | Verify rotation, mechanical seating and the original commutation reference. |
| Fit is correct but the drive reports a mismatch | Compare winding, feedback revision and drive profile to the full motor code. |
Alignment and commissioning
Capture the incoming signal reference and exact motor/encoder assembly. Compare the retained or measured angle with the specified Unimotor hd setup and matched drive procedure after installation.
Check that the cyclic resolver position agrees across slow, controlled repeat observations. Verify original polarity and scaling.
Production and availability
Request availability against the complete Unimotor hd 190UDC / 190EDC order, serial number and feedback label. SpareFaber offers installation, fault diagnosis and alignment assessment. Ask separately for part supply or replacement options.
Motor and drive applications
Control Techniques Unimotor hd application with the exact amplifier, voltage and feedback input supporting the fitted order.
Send the motor order, drive nameplate, feedback label and fault history to check the service scope and assembly revision.
Drawings and manuals
- Control Techniques servo motors catalogue BRO-SRVOMTRS. Unimotor hd order information and 190ED/190UD data for C, D and F stator lengths.
Common questions
What should I send for an evaluation?
Send the complete Unimotor hd 190UDC / 190EDC order, feedback label, connectors at both ends, drive order and the original fault or alarm.
Can I match the feedback from the motor frame?
Use the order information above, then compare the actual feedback label, signals, drawings and reference procedure.
Can you check the motor at our site?
Request a UAE site visit or bench evaluation. Share the location, equipment labels and what happened before the fault so the service team can confirm the appropriate scope.
Request service
Send the full motor and encoder IDs, drive model, connector pictures and fault history with your service enquiry. Include your location for an on-site visit.
Enquire about this encoder or resolver
Tell us what needs checking. We’ll review the details and confirm the scope and quotation before booking chargeable work.