Encoder and resolver technical library
Kollmorgen AKM2G-73 Resolver R- Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment
Kollmorgen AKM2G-73 · Resolver R-
SpareFaber offers UAE site visits and send-in evaluation for the Kollmorgen AKM2G-73. Use this guide to identify the fitted feedback, prepare the right cable and drawing, and investigate faults before ordering parts or starting alignment.
Request a UAE site visit or bench evaluation
Find your part number
Compare the motor nameplate, complete part number and fitted feedback label. Frame 7, L/N/Q windings. 100 K base Tcs reference. Use size-7 resolver matrix and correct connector/current branch.
| What to identify | Catalogue reference |
|---|---|
| Exact motor base | AKM2G-73 |
| Frame and windings | Frame 7, 192 mm square. L / N / Q windings. |
| Feedback code | R- |
| Connector route | Ad or C at ≤20 A, H above 20 A per revision and fitted order |
Include any special suffixes and clear photos of the mating connectors and the feedback mount.
What specialist testing can establish
Verify the R- motor-side route with the size-7 matrix. Test cyclic resolver angle only through an identified compatible excitation source and correctly documented fixture.
SpareFaber can assess a site visit or a send-in evaluation. Direct encoder checks and complete motor run tests require confirmed hardware and independent setup decisions.
Reference specifications
| Parameter | Catalogue value | Scope |
|---|---|---|
| Base continuous stall reference | 56.6–57.9 N·m at 100 K winding rise | Select the exact 60 K/100 K winding, mounting heat sink and installed option ratings |
| R- feedback | Inductive resolver | Confirm actual excitation, secondary connections and resolver speed |
Mechanical fit
Use the AKM2G-73 frame 7 drawing and the L / N / Q winding columns. Check mount, shaft, brake added length and connector height for R-.
Check the fitted part’s complete drawing before choosing a substitute. Compare shaft or bore, mounting dimensions, locating features and harness clearance.
Wiring and connector scope
Confirm Ad or C at ≤20 A, H above 20 A per revision and fitted order in the Kollmorgen size-7 connector matrix for the fitted motor and drive. Read the exact connection drawing for R- and trace the documented contact and shield arrangements.
Identify the connector face and drawing revision. Approved service personnel should isolate power, secure the load and verify the relevant wiring before any powered checks.
Internal wiring and machine cables
Match the complete AKM2G winding, current and connector code to the drive and cable combination. Verify whether the route uses hybrid or separate connectors, and the cable part number at both ends.
Send clear photos of both mating connectors and the cable label. Note where the harness flexes and whether a connector, cable or drive was recently replaced.
Fault checks
| Observed symptom | What to check |
|---|---|
| Feedback may be correct but the drive rejects the motor | Confirm current branch, full string and drive feedback compatibility. |
| Intermittent feedback after cable replacement | Compare actual connector and lead references with the size-7 table. |
| Position shift after mounting | Verify fitted housing and reference using the exact frame drawing. |
Alignment and commissioning
Preserve the incoming motor identity and electrical reference. Match correct mechanical position and direction to the fitted drive's commissioning reference. Record readable turns and any required re-reference procedure for the absolute option.
Check that the cyclic resolver position agrees across slow, controlled repeat observations. Verify original polarity and scaling.
Production and availability
Request availability against the complete AKM2G-73 order, serial number and feedback label. SpareFaber offers installation, fault diagnosis and alignment assessment. Ask separately for part supply or replacement options.
Motor and drive applications
Kollmorgen AKD/AKD2G or another documented matching drive with exact feedback support and current rating. Verify the motor order code and installed cable.
Send the motor order, drive nameplate, feedback label and fault history to check the service scope and assembly revision.
Drawings and manuals
- Kollmorgen AKM2G selection guide KM 000315 Rev D. AKM2G-7 technical data, feedback/connector matrix and frame 7 outlines.
Common questions
What should I send for an evaluation?
Send the complete AKM2G-73 order, feedback label, connectors at both ends, drive order and the original fault or alarm.
Can I match the feedback from the motor frame?
Use the order information above, then compare the actual feedback label, signals, drawings and reference procedure.
Can you check the motor at our site?
Request a UAE site visit or bench evaluation. Share the location, equipment labels and what happened before the fault so the service team can confirm the appropriate scope.
Request service
Send the full motor and encoder IDs, drive model, connector pictures and fault history with your service enquiry. Include your location for an on-site visit.
Enquire about this encoder or resolver
Tell us what needs checking. We’ll review the details and confirm the scope and quotation before booking chargeable work.