Encoder and resolver technical library

Siemens 1FK7101-3 G2 High Inertia SinCos 1 Vpp A Incremental Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment

Siemens 1FK7101-3 G2 High Inertia | SinCos 1 Vpp A | Incremental | Installation, Repair, Alignment workshop illustration

Siemens 1FK7101-3 G2 High Inertia · SinCos 1 Vpp A

SpareFaber offers UAE site visits and send-in evaluation for the Siemens 1FK7101-3 G2 High Inertia. Use this guide to identify the fitted feedback, prepare the right cable and drawing, and investigate faults before ordering parts or starting alignment.

Request a UAE site visit or bench evaluation

Find your part number

Compare the motor nameplate, complete part number and fitted feedback label. SH100, BC71 / BF71. A = IC2048S/R, incremental sine/cosine and commutation/reference, M0 at 100 K. Verify fitted shaft assembly and drive.

What to identify Catalogue reference
High Inertia base 1FK7101-3
Physical size Shaft height 100, High Inertia
Order example group BC71 / BF71
Feedback code A, IC2048S/R

Include any special suffixes and clear photos of the mating connectors and the feedback mount.

What specialist testing can establish

Verify the 1 Vpp measurement path, track shape, reference signal and commutation channels using an approved fixture and matched receiver. Compare signal level with correct termination and the fitted encoder drawing.

SpareFaber can assess a site visit or a send-in evaluation. Direct encoder checks and complete motor run tests require confirmed hardware and independent setup decisions.

Reference specifications

Parameter Catalogue value Scope
Stall torque 27 N·m at 100 K High Inertia 510–720 V table with exact winding and actual operating conditions
Position track 2,048 incremental sine/cosine periods, 1 Vpp Check reference and C/D commutation on the fitted encoder
Reference Incremental position system Preserve machine reference and correct analogue interpolation setting

Mechanical fit

Match the 1FK7101-3 High Inertia outline and brake option, exact shaft assembly and motor-encoder interface. Compare actual label, flange and rear mount when selecting a replacement.

Check the fitted part’s complete drawing before choosing a substitute. Compare shaft or bore, mounting dimensions, locating features and harness clearance.

Wiring and connector scope

Use the exact non-DRIVE-CLiQ A connection for supply/sense, A/B 1 Vpp, reference and C/D commutation. Keep analogue signals on their matched receiver.

Identify the connector face and drawing revision. Approved service personnel should isolate power, secure the load and verify the relevant wiring before any powered checks.

Internal wiring and machine cables

Use the High Inertia and SINAMICS reference for the complete non-DRIVE-CLiQ feedback build. Match the drive or applicable sensor interface module and exact Siemens cable code.

Send clear photos of both mating connectors and the cable label. Note where the harness flexes and whether a connector, cable or drive was recently replaced.

Fault checks

Observed symptom What to check
Feedback fails after a drive or cable change Check the exact feedback code, sensor interface module and connection type.
Axis counts but loses reference Trace the analogue reference and commutation channels against the correctly terminated drawing.
Holding brake or shaft parts differ Use the exact High Inertia part drawing for fit and clearance.

Alignment and commissioning

Capture the incoming motor/encoder code, original mechanical position and reference condition. Follow the actual Siemens reference procedure for the option, including machine homing or commutation verification.

Check analogue periods, direction, reference and commutation channels against the original setup.

Production and availability

Request availability against the complete 1FK7101-3 G2 High Inertia order, serial number and feedback label. SpareFaber offers installation, fault diagnosis and alignment assessment. Ask separately for part supply or replacement options.

Motor and drive applications

Siemens SINAMICS combination appropriate to the model and non-DRIVE-CLiQ feedback order, confirmed from the installed hardware.

Send the motor order, drive nameplate, feedback label and fault history to check the service scope and assembly revision.

Drawings and manuals

Common questions

What should I send for an evaluation?

Send the complete 1FK7101-3 G2 High Inertia order, feedback label, connectors at both ends, drive order and the original fault or alarm.

Can I match the feedback from the motor frame?

Use the order information above, then compare the actual feedback label, signals, drawings and reference procedure.

Can you check the motor at our site?

Request a UAE site visit or bench evaluation. Share the location, equipment labels and what happened before the fault so the service team can confirm the appropriate scope.

Request service

Send the full motor and encoder IDs, drive model, connector pictures and fault history with your service enquiry. Include your location for an on-site visit.

Enquire about this encoder or resolver

Tell us what needs checking. We’ll review the details and confirm the scope and quotation before booking chargeable work.

What do you need help with?