What specialist testing can show
TI-5000JX bench. Mitchell documents Bosch SF EnDat memory-read scope. Compare original ID, bytes and commutation under the supported procedure.
TI-3000JX motor run. Verify replacement acceptance with the matching Bosch drive and OEM instructions. Confirm exact motor-run fixture separately.
Starting lead. Confirm the Bosch SF motor connector and exact ID before choosing a bench lead.
Bosch Rexroth SF Series OEM HEIDENHAIN EnDat Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| ECN 1313-2048 · 312 211-03, 312 212-53, 541 786-01 | Original singleturn IDs documented in Mitchell’s Bosch SF memo. OEM areas 1–4 are 0 / 64 / 64 / 64 bytes on these examples. |
| EQN 1325-2048 · 312 214-54, 541 788-01 | Original multiturn IDs in the same memo, with the 0 / 64 / 64 / 64 byte layout. |
| 586 643-01 · 586 653-06 · 586 653-09 | Later fitted IDs reported by Mitchell. The memo lists 0 / 256 / 256 / 0 bytes. Verify programming support and the fitted drive. |
| ECN 1313-2048 · 586 643-03 | The memo records a Bosch-drive failure in a replacement trial and an OEM Area 1 size of 192 bytes on that encoder. |
Production and end-of-life status
Mitchell’s 2015 memo documents original and later IDs. Confirm present availability and approved successors by exact HEIDENHAIN ID.
Specifications
| Parameter | Verified scope |
|---|---|
| Format | OEM HEIDENHAIN EnDat on the documented Bosch SF branch. Match singleturn ECN or multiturn EQN by full ID. |
| Compatibility clue | Mitchell’s KB identifies 0 bytes allocated in OEM Area 1 on the compatible Bosch SF format. Compare the complete memory layout and fitted ID. |
| Analogue designation | The documented ECN/EQN examples carry the 2048 designation. Verify the encoder ID and matching signal drawing. |
Interface and measuring method
The drive exchanges digital position and reads OEM information over EnDat. A bench reply can be valid while the Bosch drive rejects the identity or memory structure. Keep the communication result, OEM memory report and drive alarm separate.
Mounting and fit
Record the complete Bosch SF motor and drive order and the fitted HEIDENHAIN ID. Match shaft, seat, coupling and cable exit using the exact installation drawing before considering a replacement.
Wiring and connector scope
Use the fitted Bosch SF motor and HEIDENHAIN ID drawings for supply, return, clock and data and any analogue pairs. Confirm the approved bench lead against the connector and supply rating.
Internal motor and machine cables
Obtain the Bosch motor-to-drive cable from both order codes. Use the fitted encoder connector and motor assembly drawing for the internal loom. Preserve original shield termination and strain relief.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| A new EnDat encoder reads on the bench and faults on the drive | Compare the fitted and replacement IDs and OEM Area 1, then the rest of the memory layout. |
| Memory reads but programming is rejected | Check the exact ID, software and compatibility memo before repeating the write. |
| No communication | Trace the clock/data and power circuits on the matched connector before judging memory. |
Angle of alignment and commissioning
Read and save the original memory and observed commutation reference before disassembly. Verify exact layout and motor match before a specialist transfers data or aligns the replacement.
Motor and drive applications
Bosch SF motor and matched drive
Check exact motor, full fitted ID, original memory, connector and current manufacturer availability.
Related SpareFaber guides
Drawings, pin maps and manuals
- Bosch (Rexroth) SF series encoder replacement. Compatible encoder IDs and OEM Area 1
- Mitchell Programming Bosch SF Encoders memo, revised June 2015. Exact documented IDs, memory-area sizes and recorded replacement trial.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.