What specialist testing can show
TI-5000JX bench. Check SNS identification and analogue movement signals separately on the qualified fixture.
TI-3000JX motor run. Verify the actual motor and supported run selection and preserve the received Fagor reference.
Starting lead. Choose the fitted Fagor connector. TI-5069 is documented for the matching direct SNS test arrangement.
Fagor / SICK Stegmann FXM E1 / SNS50 Sincoder Servo Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| FXM E1 · SNS50 | Fagor sinusoidal Sincoder option, with taper in the later hardware guide. |
| FXM R0 | Resolver option in the earlier FXM sales table. |
| FXM I0 | Incremental TTL option in the cited table. |
| FXM A1 | Multiturn SRM50 SinCos branch in the cited sales table. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Analogue position | 1,024 periods per turn for the cited E1 SNS50. |
| Serial functions | SNS ID and applicable OEM memory can be read with the matched setup. The SNS movement count has no absolute angle field. |
| Test hardware | TI-5104 plus a matching SNS fixture. The direct TI-5069 route requires Mitchell’s SNS-specific wiring arrangement. |
Interface and measuring method
Check the Sincoder movement count separately from serial ID and memory. An SNS OK indication establishes a valid ID read. Use the expected analogue response and the fitted drive’s commissioning procedure for movement and alignment checks.
Mounting and fit
Confirm the SNS50 taper and rear mounting against the fitted order. Inspect the seating and cable route under isolation. Record the original physical reference before lifting the encoder.
Wiring and connector scope
Use the exact Fagor motor-side diagram. The Mitchell article describes how its SNS test cable combines the required paths. Apply those details only to the named tester fixture.
Internal motor and machine cables
Identify the internal pigtail and machine cable from the full FXM order and drive. Confirm pin orientation and mating view at both ends. Record the original loom if it differs from the bench harness.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| SNS ID reads but movement count does not change | Check the analogue paths, direction and mounting. |
| FF status on the SNS test | Check the matching cable and SNS-specific test wiring before assessing the encoder. |
| Valid movement with a Fagor memory error | Record checksum, software and motor order and compare with original data. |
Angle of alignment and commissioning
Capture the received mechanical reference and original Fagor memory and checksum where supported. The SNS incremental count alone cannot establish absolute commutation angle. Follow the motor’s alignment procedure.
Motor and drive applications
Fagor FXM with E1 in the complete order
Separate E1 Sincoder from R0 resolver and I0 incremental orders before choosing a replacement or cable.
Related SpareFaber guides
Drawings, pin maps and manuals
- Mitchell Product Catalog, supported feedback. Fagor FXM/FKM and SICK SNS supported-feedback listing
- Fagor servo drive system manual, FXM motor sales references. Supplementary reference for the stated model or setup.
- SICK Stegmann SNS Suggested Test Sequence. Reference for the fitted feedback or motor option.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.