Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
A qualified technician can compare the RS-485 position/status and each analog channel using a compatible receiver or instrument. Confirm any Mitchell configuration for the exact part and loom. A bench encoder test and a complete motor run require separate setups.
Allen-Bradley 842HR Sin/Cos Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is 842HR-SJDZ115FWY2. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| 842HR-SJDZ115FWY2 | Square flange, 3/8 in solid shaft, MS 10-pin. | Singleturn, 5–12 V supply code 1. |
| 842HR-MJDZ115FWY2 | Same listed square-flange shaft and MS 10-pin connection. | Multiturn, 4,096 turns. |
| 842HR-SJDZ115FWYD | Square-flange 842HR-S with M23 17-pin connector. | Singleturn. Use the separate M23 pin map and drive cable. |
Production and end-of-life status
Rockwell's exact 842HR-SJDZ115FWY2 product record listed lifecycle Active when reviewed. Confirm regional orderability separately. Rockwell exact product record.
Specifications
| Parameter | Value and scope |
|---|---|
| Feedback | 32,768 absolute steps per turn for 842HR-S, plus 1,024 sin/cos periods per turn. |
| Supply | 5–12 V DC for code 1. 180 mA maximum no-load current in the 5–12 V family column. Allow for the documented inrush. |
| Mechanical | 3/8 in solid shaft with square flange. Operating speed up to 6,000 rpm per 842HR-IN001. |
| Environment | −20 to +85 °C. IP66 when the matching connector is inserted. |
| Connector | MS 10-pin for termination code 2. D denotes the distinct M23 17-pin version. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
Use the square-flange, solid-shaft drawing on page 2. Mount the housing on the bracket and couple the 3/8 in shaft to the driven shaft with the correct two bore sizes. Check concentricity, shaft insertion, end load and coupling slip. Rockwell lists 845-FC flexible couplings, including 845-FC-B-B for 3/8 in at both ends. Use that coupling's assembly instructions.
Interface and measuring method
The drive reads absolute position and parameters on bidirectional RS-485, then uses differential sin/cos for high-resolution motion feedback. Rockwell documents HIPERFACE compatibility. A stable serial position and faulty analog motion feedback can produce different alarms. Check each analog signal against its own reference.
Verified wiring
Use the MS 10-pin row of 842HR-IN001, page 2. Read contact letters on the connector and use its keyed view. The M23 version has different contacts.
| Contact | Function | Rockwell cable color |
|---|---|---|
| A | Supply | Red |
| B | Common | Blue |
| C | REF SIN | Brown |
| D | REF COS | Black |
| E | Data + | Gray |
| F | Data − | Green |
| G | SIN | White |
| H | COS | Pink |
| I | Unused | — |
| J | Case | Case |
Cables inside the motor and at the machine
The 842HR-CA-2-yy family uses an MS 10-pin encoder plug and flying leads. Rockwell lists -01, -03, -05 and -10 among the length options. Use the controller's cable and shielding rules. A 2090-XXNFMF-Sxx lead is documented for the different M23 variant.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Serial position absent | Check the correct single supply, return, and Data pair at both ends using the approved test method. |
| Serial good, speed signal unstable | Check SIN/REF SIN and COS/REF COS, coupling fit and cable integrity. |
| Position shifts under load | Inspect bracket and coupling retention while isolated. Verify the reference and drive configuration after repair. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Rockwell positions 842HR for auxiliary servo feedback. Kinetix documentation lists specific 842HR connector variants. Match the exact receiver and harness. The Kinetix 6000 example names the M23 suffix D, so confirm the MS version's drive-side wiring separately.
Angle of alignment and commissioning
Set the mounting and coupling alignment first. Determine whether the encoder is auxiliary axis feedback or part of a motor commutation scheme. For the latter, use the exact motor procedure and valid original offset data. Confirm direction and axis reference in the drive's approved commissioning mode.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- Kinetix 6000 user manual. Check the named M23 encoder variants and drive configuration.
- Multiturn relative. The exact MS 10-pin multiturn model.