What specialist testing can show
TI-5000JX bench. Match the B option and fitted feedback label. Verify serial data and retention through the correct connection.
TI-3000JX motor run. Verify the actual TLY motor and compatible run profile.
Starting lead. TI-5715 for the documented 28-contact Tyco CPC serial branch.
Allen-Bradley Kinetix TLY B 17-Bit Battery-Backed Serial Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| TLY, feedback code B | Rockwell specifies a 17-bit, battery-backed serial feedback option. Record the complete motor order. |
| TLY, feedback code H | Rockwell specifies 2,000-line incremental feedback. Mitchell assigns TI-5714 to the incremental TLY branch. |
| TL B with rectangular connection | Rockwell lists a different connection option. Mitchell lists TI-5733 for the documented TL Tamagawa branch. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| B position resolution | 131,072 within-turn positions in the 17-bit specification. |
| Turn retention | Rockwell’s B code has battery-backed absolute feedback. The drive and installed battery arrangement determine the retention procedure. |
| Mitchell connection | TI-5715, 28-contact Tyco CPC on the named TLY serial branch. |
Interface and measuring method
The drive uses the serial reply for position. Within-turn position can be good even when the turn count was lost through the retention path. Compare the drive’s live position and its retention alarms as separate observations.
Mounting and fit
Use the complete TLY motor order for the fitted rear assembly. Document coupling or shaft seating, cable routing and the received reference before removing the feedback. Confirm the encoder label because the motor code identifies the option rather than every internal part number.
Wiring and connector scope
The B and H branches use different feedback circuits. Match the OEM motor and drive connector views before measuring supply or tracing the serial and retention paths. The 28-contact housing alone cannot establish pin assignment.
Internal motor and machine cables
Trace the motor pigtail and the cable to the drive separately. Use both Rockwell order codes for the OEM cable and battery arrangement. Mitchell TI-5715 serves the documented diagnostic connection.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Position reads but turns disappear after a power cycle | Check retention alarms, the battery assembly and reference recovery procedure. |
| Correct plug but no feedback | Verify B or H on the motor order and match the cable to the actual serial or incremental circuit. |
| Serial errors track cable motion | Check the pigtail and the harness at each end before removing the feedback. |
Angle of alignment and commissioning
Record the motor reference and the drive’s retained-position status before service. Follow the applicable Rockwell battery and axis reference procedure. Check the fitted encoder reference and motor compatibility before any specialist write or alignment.
Motor and drive applications
Kinetix TLY B option
Identify the B serial branch, its battery connection and the difference from the H incremental wiring.
Drawings, pin maps and manuals
- Mitchell Test Cable Index by Manufacturer. Allen-Bradley, TI-5715 TLY/Tamagawa serial row and TI-5714 incremental row
- Rockwell Kinetix rotary motion specifications. TL/TLY motor catalogue, model breakdown and supported assemblies.
- Allen Bradley (Reliance, Electrocraft) Motors. Reference for the fitted feedback or motor option.
- Rockwell TL/TLY motor order code. Feedback codes B and H and connector codes 3 and 6.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.