Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
Mitchell's Generic Resolvers chapter documents the TI-5000JX J12 path and angle, vector level and phase observations. Confirm that the tester can supply the AMCI rating at the required load and that the adapter follows the exact lead drawing. Verify any TI-3000JX run separately using the actual motor, fixture, drive limits and tester profile. A resolver-only signal check can isolate the feedback from the machine loom.
AMCI R11X-J10/7 Size 11 Brushless Resolver technical reference
Find your part number
Use the full label and suffix. The main reference is R11X-J10/7. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| R11X-J10/7 | Size 11 housed resolver. Match the J10 shaft and servo mounting drawing. | One electrical cycle per turn, 7.0 V AC at 5 kHz, 0.95 transformation ratio. |
| R11X-J12/7 | J12 is a different shaft build. Check coupling bore and installed stack. | AMCI lists 1×, 5 kHz and a 0.95 ratio for this variant. |
| 11BRCX-300-J/7 | Harowe part listed by AMCI against R11X-J10/7. Compare pilot, shaft and retention. | Check the Harowe lead drawing and the receiver. AMCI lists this as a compatible part. |
| R11X-2J10/20 | Related size 11 J10 resolver. Verify the full label and drawing. | Two electrical cycles per shaft revolution. Requires a receiver configured for that resolver speed. |
Production and end-of-life status
AMCI's product record identifies R11X-J10/7 and the Harowe cross-reference. Current production and lead time for the exact order code are unconfirmed.
Specifications
| Parameter | Value and scope |
|---|---|
| Excitation | 7.0 V AC at 5,000 Hz in the AMCI R11X-J10/7 engineering table. Use the documented source and measurement convention. |
| Transformation ratio | 0.95 for this order code, specified as the output-to-excitation ratio at the defined peak-coupling position. |
| Resolver speed | 1×. The sine/cosine vector makes one electrical cycle per shaft turn. |
| Package | Size 11 servo mount. Use the model drawing for pilot, shaft and protrusion dimensions. |
| Receiver | A resolver-to-digital input rated for this excitation, ratio, phase and winding arrangement. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
Locate the resolver by its servo pilot and use the specified clamps or OEM retention. Check shaft diameter and insertion depth against the coupling drawing. Align the drive and resolver shafts with the supported coupling so the resolver bearings carry no assembly preload. A coupling that slips can shift angle while all three windings still measure normally.
Check witness marks, looseness and evidence of rubbing after isolation. Obtain the resolver and machine drawings before adjusting shaft engagement or clamp torque.
Interface and measuring method
A resolver is a rotary transformer. The receiver drives R1/R2 with an AC carrier. The shaft angle changes the signed carrier amplitudes in the sine and cosine windings. The receiver demodulates the two channels and combines their signed values to determine the angle within the turn. The two output pairs are analogue winding signals. Measure them with the documented excitation reference and input loading.
A DC meter can find an open isolated harness. The demodulated vector and angle under a controlled turn are more informative about winding balance, direction and dropouts.
Verified wiring
AMCI's resolver module manual figure on PDF page 7 shows the standard six-lead R/S winding identification. The table is for the AMCI leads in that figure. Check the supplied lead drawing before applying colours to a Harowe or OEM-built harness.
| Winding | Lead pair |
|---|---|
| Excitation | R1 red/white, R2 black/white |
| Sine | S1 red, S3 black |
| Cosine | S2 yellow, S4 blue |
Use the receiver's termination and screen drawing for the far end. Keep the three pairs separate and check the phase designations at each end.
Cables inside the motor and at the machine
The standard resolver has flying winding leads. The machine loom ends at the actual resolver interface or drive connector. Order it by the machine drawing and record both ends, cable run and screen bond. Verify each paired conductor before repinning. AMCI module connector diagrams apply to their named module, not to a generic motor bulkhead.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Excitation absent | Check the receiver settings and source first. Compare its carrier at the documented breakout and the resolver end in the approved setup. |
| One channel low or missing | Trace that isolated pair, then check the signed waveform and compare both channels at equivalent shaft positions. |
| Angle is reversed or wraps twice | Check winding polarity, receiver direction and resolver speed. Confirm the full code and inspect the coupling. |
| Angle jumps after load changes | Inspect coupling slippage or play and repeat a slow controlled turn with the receiver logging angle and amplitude. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
This guide covers the standalone housed AMCI resolver and its documented Harowe cross-reference. A motor with this type of feedback may need separate instructions for excitation, poles and commutation reference. Compare the nameplate, resolver tag and feedback receiver before treating it as an OEM motor replacement.
Angle of alignment and commissioning
Record the original shaft datum and sign before disturbing the coupling. Set reference according to the controller or motor procedure. For commutated motors, validate the motor's electrical reference with the OEM method and the installed resolver speed. The resolver windings contain no digital motor-memory record to copy.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- AMCI R11 electrical and cross-reference tables. Use the exact J10/7 row and the family mechanical drawing.
- Mitchell generic resolver testing. See setup, phase, vector level and resolver speed.