Site visit or send-in evaluation
Sensor and magnetic strip diagnosis, Board-level evaluation. Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
A board fixture can check power, magnet diagnostics, A/B/index, synchronous serial or PWM as used by the host. Use the approved fixture and ESD controls. A general motor encoder tester does not identify a board pinout.
ams OSRAM AS5311 AS5311-ATST Magnetic Linear Encoder IC technical reference
Find your part number
Use the full label and suffix. The main reference is AS5311-ATST. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
Manufacturer device order code
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| AS5311-ATST | 20-pin TSSOP encoder IC. Confirm board footprint and magnet layout. | Incremental A/B/index, SSI-style serial and PWM functions documented for the IC. |
| AS5311-ATSU | Order variant listed in the same sheet. Confirm packaging and component revision. | Use the exact bill of materials and order guide before changing the board. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Sensing | Hall-based position sensing with a multipole magnetic strip or ring. |
| Position within a pole pair | 12-bit position over the specified 2 mm pole pair. Multi-pole travel needs the host’s tracking and reference. |
| Output groups | A/B/index, serial clock and data, PWM and magnet range diagnostics. |
| Board and supply | 20-pin TSSOP. Follow the exact 3 V or 5 V configuration and logic-level guidance in the data sheet. |
| Mechanical interface | Magnetic strip or ring is external. Use the manufacturer geometry and field requirements. |
The table identifies the assembly each value applies to. Main technical PDF.
Mounting and fit
Use the board drawing and datasheet magnet orientation. Check package placement, strip pitch, relative motion and the sensor-to-magnet spacing. Magnet strength and alignment affect signal quality even when the host supply is correct.
Interface and measuring method
Incremental outputs track relative movement. The synchronous serial and PWM position information represents position within a magnetic pole pair. The host needs the correct reference or counting method to distinguish repeated periods along a long strip.
Verified wiring
IC package pin numbers below come from the AS5311 data sheet. Use the PCB’s view and host schematic before probing.
| Contact or group | Function |
|---|---|
| 4 / 5 / 7 | Incremental A / B / index. |
| 12 / 13 / 14 | Serial DO / CLK / active-low CSn. Follow the datasheet’s mode and timing requirements. |
| 2 / 3 / 15 | MagINCn / MagDECn / PWM. |
| 8 / 18 / 19 | VSS / VDD3V3 / VDD5V. Use the published supply circuit for the selected mode. |
| Other pins | Check the datasheet for NC and Prog handling. Keep unconnected pins as specified. |
Cables inside the motor and at the machine
This is an IC with no standalone motor cable. Identify board nets and the host connector from the system schematic. If the host harness is part of the symptom, verify its exact end-to-end path separately.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Use ESD controls and de-energize the board before inspecting or changing connections. Follow the PCB schematic and use its documented test points.
| Observation | What to verify |
|---|---|
| Feedback only works at some points of travel | Inspect strip condition, alignment and spacing. Compare the magnet diagnostics with the mechanical position. |
| Repeating absolute position every pole pair | Check whether the host expects within-period data or full travel. Verify the reference and incremental accumulation. |
| No incremental transitions with valid serial response | Check the mode-select state and board receiver. Verify A/B with the published circuit and logic levels. |
Powered checks. A qualified technician can use the approved host-board test setup to verify the configured supply, logic signals and magnet response. Isolate the board before changing connections.
Motor and drive applications
Use in embedded linear or off-axis position systems designed for the AS5311. Record the PCB revision, magnetic strip or ring and host firmware. The exact implementation determines test access.
Angle of alignment and commissioning
Establish the sensor-to-magnet geometry and host reference using the machine or board instructions. Confirm the reported position throughout travel after any board or strip replacement.
Drawings, pin maps and manuals
- Main technical PDF. ams manufacturer data sheet, public mirror. Use pin table, supply configuration and magnet mounting sections.
- Manufacturer reference. Current AS5311 product documentation is hosted by Infineon. The referenced legacy data sheet identifies the ams ordering code.