What specialist testing can show
TI-5000JX bench. On the documented connection, check movement, index where fitted and commutation separately.
TI-3000JX motor run. Confirm the full motor order, power lead, phase reference and supported TI-3000JX setup.
Starting lead. TI-5691 on the documented 17-contact M23.
Axor Super SAX SSAX Tamagawa OIH ABZ/UVW Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| SSAX with Tamagawa OIH | Scoped Mitchell application with ABZ movement and UVW commutation. Read the actual OIH suffix. |
| Other Super SAX feedback | Axor lists different resolver, commutation encoder and serial choices in the family. |
| Applikon OIH35 | Another documented OIH application with a different motor-side cable. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Motion | Incremental ABZ on the documented branch. |
| Commutation | Separate UVW channels. Verify the motor pole count and fitted output. |
| Starting lead | TI-5691, 17-contact M23. |
Interface and measuring method
A/B edges give motion and direction and Z is the reference. Check the UVW circuit separately when counts appear but the motor faults at enable.
Mounting and fit
Use the Axor frame drawing and fitted OIH drawing for mounting. Record shaft seat, restraint and incoming electrical reference before disassembly.
Wiring and connector scope
Find the commutation-encoder diagram for the exact connector option in the Axor sheet. Match the keyed mating view and encoder supply before applying the fixture.
Internal motor and machine cables
Trace the encoder pigtail to the bulkhead and verify the drive extension separately. Keep the Axor test lead and machine harness distinct.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Drive rejects feedback at enable | Check UVW order and phase relation. |
| No index with working A/B | Verify the fitted Z channel and drive reference source. |
| Fault follows motor cable movement | Inspect M23 retention and isolated wiring. |
Angle of alignment and commissioning
Preserve count direction, index and commutation relative to the motor phases. Use the procedure for the actual Axor drive and order.
Motor and drive applications
Axor SSAX on the documented 17-contact M23 OIH branch
Match the Axor commutation encoder order and pin view before reusing a cable from another OIH application.
Drawings, pin maps and manuals
- Mitchell Test Cable Index by Manufacturer Support. Axor Support Part Numbers, TI-5691
- Axor Super SAX SSAX datasheet and connector drawings. Supplementary reference for the stated model or setup.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.