Encoder and resolver technical library
Baumüller DS2-160BO23A/R HIPERFACE SRS50 / SRM50 Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment
Baumüller DS2-160BO23A/R with documented D / SRS50 singleturn or E / SRM50 multiturn classic HIPERFACE feedback is covered in this combined configuration guide. Identify the fitted device, compare the singleturn/multiturn branches, preserve incoming alignment and readable motor data, and prepare a scoped UAE site visit or send-in evaluation for installation, repair and alignment.
Identification · Testing scope · ST/MT comparison · Wiring · Drawings and manuals · Service enquiry
Identify the fitted configuration
| Item | Documented scope |
|---|---|
| Manufacturer / grouped motor base | Baumüller DS2-160BO23A/R |
| Frame | 160; compare the actual mounting/envelope drawing |
| Housing / cooling | IP23 internally ventilated, standard axial/radial fan alternatives |
| Feedback coverage | D — SRS50 singleturn; E — SRM50 multiturn; classic HIPERFACE |
| Identifier boundary | Grouped motor base and documented feedback choices, not a complete OEM motor order |
| Service reference | TCG1539 — SpareFaber reference, not an OEM part number |
Read the complete motor type, serial, speed/winding fields, actual A or R fan selection, mounting, shaft and brake order. Record the fitted encoder model, suffix, serial, interface marking, connector photos and drive model. The shared guide keeps ST and MT information together; it does not authorize exchanging devices or transferring another motor's parameters.
The D/E branch is classic HIPERFACE, with serial RS-485 position and separate analogue sine/cosine signals. Other SICK, safety or single-cable feedback codes require their own identification.
Specialist feedback testing
TI-5000JX scope: evaluate positively identified SRS50/SRM50 feedback with the matching installed Athena selection. Check serial position/status and the analogue path separately, preserving valid incoming alignment and readable memory before any changes.
Starting direct-to-encoder evidence: Mitchell's Stegmann Absolute Encoders section identifies TI-5069 for the SRS/SRM encoder plug and TI-5104 after label/supply verification. This is a direct encoder connection, not a verified DS2/DS3 motor-bulkhead adapter.
Record the test equipment, lead/module, selected device, installed software version and fitted encoder label with the report. A changing serial count alone does not prove clean analogue signals, correct installation, preserved commutation or a valid motor-data interpretation. No exact minimum firmware version is asserted for this complete assembly.
Motor-run scope: feedback testing and TI-3000JX motor-run approval are separate decisions. Confirm the complete motor parameters, pole count, phase convention, current/speed limits, load, fixture, brake and installed motor profile before a run test. Do not reuse a DSD2, another DS2 frame or another manufacturer's run profile just because the feedback protocol matches.
Signals, motor data and singleturn/multiturn comparison
| Motor parameter | Catalogue value / boundary |
|---|---|
| Grouped base | DS2-160BO23A/R |
| Catalogue M0 | Up to 695 Nm in the grouped-base rows on p.22; match the selected speed/winding row and conditions |
| Catalogue motor mass | 310 kg reference base mass; exact fitted options and brake change the assembly |
| Cooling / protection | IP23 internally ventilated, standard axial/radial fan alternatives |
| Rated torque MN and momentary M0,max | Separate catalogue quantities; neither is interchangeable with the M0 priority value |
| Complete speed / winding / supply order | Not assigned by the abbreviated base identifier; verify the full nameplate and drive data |
| Holding brake | Presence, module, supply and rating depend on the complete brake order; identify before release or service |
| Feedback item | D / SRS50 singleturn | E / SRM50 multiturn |
|---|---|---|
| Interface | Classic HIPERFACE | Classic HIPERFACE |
| Absolute positions / revolution | 32,768 (15 bits) | 32,768 (15 bits) |
| Analogue sine/cosine periods / revolution | 1,024 | 1,024 |
| Absolute revolution information | One revolution; no retained turn range | 4,096 revolutions |
| Scoped OEM feedback supply | 7–12 V DC; check the fitted label | 7–12 V DC; check the fitted label |
| Additional service record | Single-revolution reference and supported motor data | Single-revolution reference, incoming turn count and supported motor data |
Serial absolute positions, analogue periods, multiturn range and controller-scaled counts are different quantities. A period count is not a presumed drive resolution. Motor/drive supply, feedback supply, fan supply and brake supply are separate circuits. Catalogue motor ratings depend on the selected complete order and cooling conditions, not the encoder's own maximum speed.
Mechanical fit, cooling and retention
DS2-160BO23A/R belongs to the frame-160 group. Its reviewed catalogue reference reaches 695 Nm M0 and lists a 310 kg base mass. Use the dimensional sheets on pp.69–71 with the complete ordered build; frame size and base mass do not supply a verified encoder mounting dimension.
A and R identify different external-fan orientations. The electrical catalogue groups them, while the fan position, brake access and dimensional drawings must be matched separately.
The abbreviated guide grouping omits speed/winding, complete mounting and shaft selections and special-order suffixes. Confirm all of them before comparing the motor envelope or ordering a component.
The OEM dimensional sheet describes the motor envelope, mounting and shaft arrangement. It does not by itself establish the encoder taper, locating seat, coupling fastener torque, permitted air gap or every internal loom. Record the incoming shaft reference, locating/coupling arrangement, anti-rotation support, fastener positions and cable route before loosening retention.
Use the appropriate handling and support arrangement for the actual assembly mass. Match brake extension, fan/cooling clearance and connector access against the exact drawing. Retain or obtain the motor/encoder assembly information needed for refitting and alignment rather than borrowing values from a visually similar motor.
Wiring and connector boundaries
The OEM p.53 table shows the contact side of the 12-contact motor socket for the SRS/SRM50 branch. It is not the encoder's internal direct plug, a drive-end connector or a tester terminal-board map. Match the actual contact view, keying and revision before using the assignments below.
| OEM motor feedback contact | Signal in the p.53 base diagram |
|---|---|
| 1 | cos − |
| 2 | RS-485 + |
| 3 / 4 | Not assigned in the base diagram; confirm any fitted thermal option |
| 5 / 6 | sin + / sin − |
| 7 | RS-485 − |
| 8 | cos + |
| 9 / 11 | Not assigned in the base diagram |
| 10 | GND |
| 12 | +U feedback supply |
Confirm the full thermal-sensor and feedback order before assessing contacts that are not assigned in the base diagram. Motor power, fan and brake connections are separate; their voltages and terminal maps do not come from this feedback table.
Keep the original shielding, connector shell/earth convention, contact orientation and both-end cable information with the record. A protocol name is not a pinout. Disconnect both cable ends and account for intended shield bonds when performing isolated continuity/short checks. No assignment on this page is an instruction to wire directly to an unidentified Mitchell test terminal.
Internal, machine and test cables
Treat the internal encoder loom, direct-to-encoder bench lead, motor-bulkhead adapter, machine extension and drive-end cable as separate interfaces. Record both-end connector photos, pin views, keying, cable labels, required length, routing and any shield/sense terminations before selecting a replacement.
TI-5069/TI-5104 evidence here applies only after positive SRS/SRM encoder-plug and supply identification. A verified DS2/DS3 motor-bulkhead adapter or complete machine-cable part number has not been established for every full motor suffix.
The OEM cable chapters for b maXX 4000 and b maXX 5000 describe manufacturer cable/order contexts. Read the selected encoder, drive end, connector revision and length together; an OEM machine cable is not automatically a Mitchell test adapter. Retain the actual cable drawing in the service file and confirm any adaptation with the applicable supplier information.
Practical fault checks
Before physical checks, secure the driven load, isolate and lock out relevant energy sources, observe the specified discharge time and have a qualified technician verify isolation. Powered measurements, rotation, brake release and alignment require the applicable specialist procedure and an identified setup.
| Symptom | Useful next check |
|---|---|
| No serial data or intermittent communication | Confirm the actual device/interface and installed selection, verified feedback supply and the correct serial pairs. Separate a cable/connector fault from a device fault using the identified setup. |
| Absolute position changes but analogue signals are weak/noisy | Where analogue outputs are documented and accessible, evaluate amplitude/quality separately and inspect shielding/contamination/cable condition. A serial-position pass does not clear the analogue path. |
| Direction, scale or commutation differs after service | Compare the full feedback choice, drive scaling/direction, motor pole/phase convention, saved parameters and incoming mechanical reference. Do not transfer another motor's offset. |
| Multiturn value disagrees with the machine reference | Preserve the incoming turn count and shaft history, then compare the machine reference and supported data under the approved procedure. A turn discrepancy is not proof of a battery fault. |
| Fault follows cable movement | With isolation verified, check strain relief, connector seating, pin retention, moisture and both-end continuity against the actual drawing. |
| Motor run/brake/fan fault despite a feedback pass | Review the separately approved motor-run setup, load and brake state, fan/cooling operation and power connections. Feedback evaluation does not prove those systems are correct. |
Incoming alignment, offsets and memory
Before loosening, removing, resetting or programming feedback, record the incoming mechanical reference, supported commutation/alignment indication, motor pole count, direction and phase convention. Save the drive offsets and parameters and readable encoder identity, memory/status and offset data. Tie all records to the motor/encoder serials and the exact test setup.
Retain or reproduce a valid incoming alignment under the applicable specialist method, then verify it after refitting. A retained memory image alone does not prove correct physical alignment. Where motor-specific memory decoding is unavailable, preserve readable data without presenting a raw backup as a verified commutation value.
For a singleturn device, retain the within-revolution reference and distinguish it from machine-level multi-revolution referencing. For a multiturn device, additionally preserve and assess the incoming revolution count against shaft history and machine reference. The shared guide does not remove that difference.
If the feedback was already disturbed, the incoming reference is invalid, or data is absent, corrupt or unreadable, record that limitation and obtain the motor-specific recovery method. No universal angle, automatic recovery or default data transfer from a similar motor is established here. Confirm the full hardware and data format before a memory write.
Production and replacement status
Baumüller document 5.23022.01, status 11/2025, documents the grouped motor and listed feedback choices. Catalogue inclusion is not proof of current stock, production status of every full order, or a drop-in encoder/motor successor.
Check the complete motor order/serial, fitted encoder suffix, hardware revision and applicable current drawing with the supplier before ordering. The service listing is for identification and a scoped technical evaluation; parts, repair extent and turnaround follow review of the fitted assembly and fault. A/R, I and W layouts and DS2/DS3 designations must remain correctly identified.
Motor applications and related feedback coverage
This guide concerns the large-frame DS2-160BO23A/R group and its Classic HIPERFACE feedback choices. It is useful when separating an encoder/lead/setup problem from a motor, brake, fan/cooling or drive issue in the fitted machine. Match the complete machine requirements and ordered motor before selecting a replacement or test procedure.
D/SRS50 and E/SRM50 share classic HIPERFACE while differing in revolution information. Other safety, SICK single-cable, SSI or EnDat branches retain their own electrical and software requirements.
Related DS2-160BO23A/R Heidenhain EnDat guide — additional interface-family identification context, not a substitution approval.
Drawings and primary documents
- Baumüller DS2[3]-100–200 technical documentation, 5.23022.01, 11/2025 — p.11 motor-data definitions; pp.12–13 type code; p.22 selected motor data; pp.69–71 dimensional sheets.
- OEM SRS50/SRM50 feedback and motor connector, p.53
- OEM cable chapters, pp.60–65 — b maXX drive/cable ordering context; match the actual interface and drive.
- Baumüller DS2 manufacturer family page — family reference, not exact-order stock confirmation.
- Mitchell: SICK Stegmann HIPERFACE — fitted device identification, serial/analogue testing and supported software boundaries.
- Mitchell: MOOG Motors, Stegmann Absolute Encoders section — direct SRS/SRM encoder-lead evidence only, not a DS2/DS3 motor adapter or MOOG profile approval.
Exact application evidence: Motor base DS2-160BO23A/R: OEM p.22; frame/cooling and full-order fields pp.12–13; dimensional sheets pp.69–71; D/E SRS50/SRM50 p.53. Source scope reviewed 23 November 2026.
Use the revision, complete fitted labels and actual connector drawing together. Retain a mismatch for investigation rather than selecting a pinout, replacement or test profile by appearance.
FAQ and service enquiry
Why are singleturn and multiturn covered together?
They share this motor-base/interface-family guide, with their position, revolution, connection and data differences compared inside the page. Shared coverage is not an interchangeability approval.
Does the short motor-base identifier specify a complete order?
No. Confirm the complete speed/winding, cooling, mounting, shaft, brake, feedback and special-build fields plus both serial labels before planning work.
Can the feedback be evaluated without a verified motor-run profile?
Device-level evaluation can be scoped after positive identification, connection/supply checks and confirmation of the installed tester selection. A motor run remains a separate setup and approval.
What if the original alignment or memory is missing?
Record the limitation, retain all readable incoming information and obtain the motor-specific recovery method. A default angle or another motor's data is not a verified recovery.
What information should accompany the service enquiry?
Provide complete motor/encoder labels, drive model, connector and cable photos, alarm text, fault timing, service history and any saved incoming alignment/parameter/data records. Include the actual fan/cooling and brake build.
Request a UAE site visit or send-in evaluation. The scope, parts and turnaround are confirmed after reviewing the fitted configuration and fault.
Enquire about this encoder or resolver
Tell us what needs checking. We’ll review the details and confirm the scope and quotation before booking chargeable work.