What specialist testing can show
TI-5000JX bench. Use the documented HIPERFACE selection on the TI-5000JX after checking the fitted suffix, rated supply and fixture.
TI-3000JX motor run. Mitchell documents P6 SRS Hiper for matching six-pole Baumüller motors, conditional on the specified alignment.
Starting lead. TI-5063 in the documented SRS50/60 table. Verify the connector and TI-5104 supply compatibility. Module TI-5104 where the documented branch and fitted voltage permit it.
Baumüller SRS60 Six-Pole Servo HIPERFACE Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| SRS60 | Stegmann singleturn family named in Mitchell’s six-pole Baumüller selection. Verify the fitted SRS60 suffix. |
| SRS50 | Another singleturn family under the P6 SRS Hiper tester selection. Mounting and the exact connector depend on the fitted assembly. |
| SRM50 or SRM60 | Separate multiturn branch under P6 SRM Hiper. Check the device label instead of inferring it from the motor frame. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Feedback | Classic HIPERFACE absolute singleturn plus sine/cosine channels on the named SRS60 branch. |
| Position and increments | Mitchell’s combined SRS50/60 table lists 32,768 position counts and 4,096 incremental counts per revolution. The incremental value is a tester count. |
| Run condition | Six motor poles and the documented alignment condition for the Mitchell Baumüller option. |
| Adapter | Mitchell discusses TI-5104. Verify the fitted encoder supply rating and correct adapter before connecting. |
Interface and measuring method
The drive reads absolute angle over the HIPERFACE serial link and tracks changes using the analogue sine and cosine channels. Comparing serial position with signal quality helps separate intermittent data communication from motion tracking faults.
Mounting and fit
Record the fitted encoder body restraint, rotor or shaft attachment and axial seat. Confirm the SRS60 suffix and motor frame before sourcing a mounting drawing. Use the exact Baumüller assembly instructions if torque or coupling position is required.
Wiring and connector scope
Use the cable row for the actual connector in Mitchell’s supported-types chart and the fitted motor diagram. Keep supply, return, serial data and sine/cosine pairs distinct. Verify the permitted supply before using any adapter.
Internal motor and machine cables
A matching test cable supports diagnosis at one connection point. For the installed motor harness, obtain the encoder connector, bulkhead type and full motor order to identify the OEM part or rebuild against the approved map.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Stegmann error during setup | Verify the SRS selection, connector, supply and adapter. Inspect the isolated harness before changing the encoder. |
| Serial angle reads but the position is noisy in motion | Check the paired sine and cosine signals and their shield path using the matched fixture. Inspect the mechanical seat. |
| Count is smooth but the motor will not commutate correctly | Confirm six poles, the alignment reference and actual SRS versus SRM profile. |
Angle of alignment and commissioning
Mitchell’s documented Baumüller run setup applies where the measured alignment matches its reference. Capture the incoming motor position and serial data before removal. Verify the exact reference and convention on the fitted motor instead of applying a family angle.
Motor and drive applications
Baumüller six-pole servo with a verified SICK SRS60
Confirm the full SRS60 suffix, motor order, connector and measured alignment reference.
Drawings, pin maps and manuals
- Baumuller Motors. General Comments and six-pole SRS feedback type
- Mitchell Baumüller supported types and cables. SRS and SRM rows, count format and TI-5063 lead.
- Mitchell HIPERFACE training reference. HIPERFACE identity, position and analogue signal checks.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.