What specialist testing can show
TI-5000JX bench. Check excitation and both returns at the verified AM3 connector.
TI-3000JX motor run. Verify motor order, phase map, pole count and resolver alignment before a generic run setup.
Starting lead. TI-5905 on the documented 12-contact M23 resolver branch.
Beckhoff AM3000 Standard Servo Motor Resolver technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| AM3000 resolver code 0 | Two-pole passive resolver in the Beckhoff order breakdown. |
| 12-contact round M23 | Match the male connector view in the OEM resolver drawing. |
| 12-contact Y-Tec | A separate resolver connection layout with the same contact count. Confirm the fitted plug and its diagram. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Feedback element | Two poles, one electrical cycle per mechanical revolution on the listed resolver. |
| Signal circuits | AC reference winding and sine/cosine return windings. |
| Connection | TI-5905 bench path on the documented 12-contact M23 arrangement. |
| Drive scope | Beckhoff shows AX5000 and AX2000 resolver diagrams separately. |
Interface and measuring method
The drive supplies AC excitation and calculates position from the two returned voltages. A weak reference can lower both channels together. Check excitation and the harness before comparing the windings.
Mounting and fit
Record the incoming rotor-to-resolver reference and cable routing. Use the fitted AM3000 frame and rear assembly documents to establish resolver seating, clearance and allowable service access. A similar AM3000 housing can have serial feedback.
Wiring and connector scope
Use Beckhoff’s round connector drawing for the actual AX drive. Identify reference, sine, cosine and thermal paths using the male view. The AX5000 and AX2000 drive ends have different connector drawings.
Internal motor and machine cables
Beckhoff identifies ZK4530-0010-xxxx as a drag-chain-suitable resolver cable for the applicable M23 setup. Check drive end and required length before ordering. The internal link and the TI-5905 bench fixture are separate references.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
A resolver is passive. Check isolated winding continuity against the matching drawing. Use the specified AC excitation on the approved test fixture for a signal check.
| Symptom | What to verify |
|---|---|
| Both sine and cosine levels low | Verify the reference circuit and cable first. Compare the isolated windings with the specified resolver. |
| Angle jumps with cable motion | Check the connector shell, mating contact and flexing section of the resolver cable. |
| Fault after bearing service | Verify resolver seating and compare the incoming alignment record before drive commissioning. |
Angle of alignment and commissioning
Capture the incoming resolver angle and motor polarity. Mitchell gives standard AM alignment examples. Verify the complete motor, direction and fitted resolver before using the specific OEM and tester procedure.
Motor and drive applications
Beckhoff AM3000 with standard resolver
Identify the standard resolver before selecting the AM3 cable, and distinguish it from EnDat or BiSS options.
Related SpareFaber guides
Drawings, pin maps and manuals
- Beckhoff AM Series Motors. AM2/AM3 resolver connection and AM3 standard feedback
- Beckhoff AM3000/AM3500 operating instructions. Order code and electrical installation chapter. Round and Y-Tec resolver diagrams and drive-specific terminations.
- Beckhoff ZK4530-0010 resolver cable. M23 resolver cable family. Check service phase availability and the matched drive end.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation