What specialist testing can show
TI-5000JX bench. Use the named test connection after confirming the fitted encoder label and profile.
TI-3000JX motor run. Confirm the full motor order, power lead, phase reference and supported TI-3000JX setup.
Starting lead. TI-5706 for the scoped 12-contact M23 connection.
Berger Lahr / SIG Positec SER3xx / Stegmann CDD Servo Motor Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| SER3xx / Stegmann CDD | Scope of the Mitchell TI-5706 12-contact M23 entry. Verify the fitted encoder identification. |
| Other SER3xx feedback | The motor manual lists SRS singleturn SinCos, SRM multiturn, resolver and digital DiCode. Check the exact model code and firmware. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Starting lead | TI-5706 for the named 12-contact M23 branch. |
| Fitted protocol | Confirm the actual label and software selection for the CDD connection. |
| Mechanical data | Use the SER3xx/RIG3xx manual drawing for the exact frame and assembly. |
Interface and measuring method
Separate the motor family, connector and feedback profile during diagnosis. Check the supported signal path only after the label and documented setup agree.
Mounting and fit
Identify the rear assembly and encoder restraint before removal. Compare the exact frame drawing, center fixing and cable exit and preserve the incoming reference.
Wiring and connector scope
Use the full order and motor-side map to identify supply and signals. Verify the mating view before connecting the CDD fixture.
Internal motor and machine cables
Trace the internal pigtail, 12-contact bulkhead and drive extension separately. Record the CDD cable and motor revision for sourcing.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Fixture fits but feedback is absent | Confirm the CDD option and fitted wiring. |
| Position or feedback type changes after service | Check the old and replacement labels and drive selection. |
| Intermittent failure at the motor | Isolate-test the correct harness and check the motor connector lock. |
Angle of alignment and commissioning
Record mechanical and electrical reference plus the fitted controller setup. Use the documented motor and encoder procedure for any alignment or memory work.
Motor and drive applications
Berger Lahr SER3xx on the documented 12-contact M23 branch
Identify the original motor feedback option before using a generic SICK fixture or replacing a cable.
Related SpareFaber guides
Drawings, pin maps and manuals
- Mitchell Test Cable Index by Manufacturer Support. Berger Lahr section, TI-5706 SER3xx / SIG Positec / Stegmann CDD
- Berger Lahr SER3xx/RIG3xx motor technical documentation, V1.02. Supplementary reference for the stated model or setup.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.