Identify the fitted motor and feedback
| Configuration | MKD112A-024 / G |
|---|---|
| Order-number scope | Scoped motor/winding and feedback selection; remaining OEM order suffixes require fitted nameplate. Winding suffixes do not create extra coverage. |
| Feedback interface | Resolver + digital board |
| Service scope | Motor feedback assessment; this listing is not an offer of a stocked replacement motor or encoder. |
Photograph the complete motor label, encoder label, connectors and mounting arrangement. Record the drive model and actual alarm text. The guide identifier describes the selected configuration; the received assembly must still match it, especially after an earlier repair.
Specialist testing: confirm the connection first
| TI-5000JX scope | Separate resolver response/alignment and digital-board checks; the G configuration does not include the K multiturn counter. |
|---|---|
| Cable / fixture boundary | TI-5924 for resolver evaluation; TI-5040 revision C plus TI-5104 for the separate digital-board procedure. |
| TI-3000JX run scope | Mitchell documents a Generic Resolver run path after successful resolver checks, with measured alignment entered manually and motor parameters/excitation matched. This does not test the digital board’s operating path or K multiturn counter; motor and tester limits still apply. |
Confirm the installed software selection, actual feedback option and fixture before applying power. Named family support establishes a route for evaluation, not automatic acceptance of every winding or repaired sensor combination. Record what the test actually covered and any excluded functions.
Production and replacement status
The linked manufacturer document identifies this catalogue configuration. Current production, availability and any approved successor require confirmation against the complete fitted order. A downloadable manual does not prove present stock. Compare voltage, winding, mounting, shaft, brake, feedback, connector and stored motor-data requirements before accepting a replacement.
Specifications and interface
| Selected motor / feedback | MKD112A-024 / G |
|---|---|
| Representative build | MKD112A-024 / G / brake code 1 |
| Feedback interface | Resolver + digital board |
| Flange size | 192 mm |
| Reference shaft diameter | 32 mm; confirm the fitted shaft option |
| Representative brake | OEM holding-brake code 1 |
| Order-number scope | Scoped motor/winding and feedback selection; remaining OEM order suffixes require fitted nameplate. Winding suffixes do not create extra coverage. |
| OEM evidence | 92,99 |
| Configuration note | Resolver and proprietary board tests are separate; no K multiturn-count claim. |
MKD G combines resolver feedback and a separate digital board. Treat the analogue response and stored board data as different tests. A board readable from an external DC supply may still have a fault in the drive’s excitation-powered path. Mitchell does not support the K multiturn-counting function.
Mechanical fit and retention
The verified flange and reference shaft sizes establish the selected mechanical family. Select the exact brake-code-1 drawing, winding, pilot, housing/cooling and connector direction for the received unit. No no-brake axial dimension is carried over to this braked representative.
Record the shaft datum, coupling position, pilot fit and feedback retention before disassembly. Inspect bearing play, shaft damage, contamination and moisture. Motor flange and shaft dimensions do not define the encoder coupling or its tightening torque. Use the actual assembly drawing for fasteners, retention and sealing, and record any previous modifications.
Wiring and connector boundaries
Use the dedicated MKD resolver/board sequence, including the specified connection state and revision-C board cable. Do not test the board and resolver as if they were a generic serial encoder.
Separate motor power, protective earth, low-voltage feedback and temperature circuits. Verify contact numbering, gender, keying and mating-face versus wire-side view. A connector that mates mechanically does not prove electrical compatibility. Check the permitted sensor supply or resolver excitation from its own documentation; the motor voltage rating is a different quantity.
The representative configuration includes OEM holding-brake code 1. Confirm the actual brake label, separate supply and release condition before movement. A feedback assessment does not certify braking torque or the machine holding arrangement.
Internal loom and machine cables
Record the internal encoder-to-motor loom separately from the external machine cable and bench fixture. The internal loom part number is not established by the frame or interface alone. Obtain both connector faces, the assembly diagram and the correct contact view. Match cable length, shielding, temperature rating and fixed or flexing duty to the installation. A Mitchell test lead identifies a test connection; it is not an OEM replacement machine cable.
Fault checks and useful observations
| No feedback communication | Confirm the exact interface, fixture, supply and contact orientation. Check the selected connection boundary before concluding that the sensor is defective. |
|---|---|
| Position jumps or intermittent alarms | Record direction, movement range, cable position and temperature. Compare a stationary cable check with controlled movement where the supported setup permits it. |
| Fault after encoder or bearing work | Compare the incoming memory/reference record, fitted sensor identity, mechanical retention and phase relationship. A stable position display does not establish correct commutation. |
| Bench result differs from the machine | Check which loom, connector, drive interface and operating conditions the bench bypassed. Reproduce the actual symptom before recommending a component change. |
| Motor motion or holding issue | The representative configuration includes OEM holding-brake code 1. Confirm the actual brake label, separate supply and release condition before movement. A feedback assessment does not certify braking torque or the machine holding arrangement. |
Keep each observation separate from the conclusion. State whether a fault is repeatable, which connection was tested and what changed after cleaning or adjustment. Avoid replacing an encoder solely because the drive reports a feedback alarm; a damaged cable, incorrect parameter or mechanical problem can produce a similar report.
Alignment, reference and stored data
Preserve the individual motor’s stored alignment and readable identity before removal. Resolver response and digital-board tests remain separate on MKD. Follow the powered-down connection changes in the dedicated procedure; a successful memory read alone does not establish the whole drive feedback path.
Preserve original records before any permitted change. An alignment operation concerns the motor/feedback relationship; machine home, travel limits and process offsets remain separate. Check the fitted procedure and document the measured result after reassembly.
Motor, drive and replacement matching
Match the complete chain: motor order, feedback option, internal loom, motor bulkhead, external cable and drive configuration. Similar frame size, speed or interface wording does not establish interchangeability. Confirm shaft and flange fit, brake requirements, thermal sensor, winding and stored-data requirements before approving a substitute.
Mitchell documents a Generic Resolver run path after successful resolver checks, with measured alignment entered manually and motor parameters/excitation matched. This does not test the digital board’s operating path or K multiturn counter; motor and tester limits still apply.
Drawings, manuals and supporting evidence
- Mitchell motor-family / feedback support
- OEM motor documentation: 92,99
- Mitchell Indramat cable index
Source review: 21 November 2026. The linked OEM drawing identifies the stated catalogue/configuration scope. Confirm the document revision and complete fitted nameplate before extending wiring, replacement or motor-run claims. Legacy OEM manuals may be hosted by an independent document archive.
Common service questions
Is this a complete replacement order number?
Scoped motor/winding and feedback selection; remaining OEM order suffixes require fitted nameplate. Winding suffixes do not create extra coverage.
Does a good position reading clear the whole axis?
No. Feedback, motor power, drive behaviour, machine cable, holding arrangements and loaded performance are separate evaluation boundaries.
Can the original encoder be replaced by another with the same interface?
Only after the mechanical fit, electrical connection, exact sensor/profile, stored data and alignment requirements have been checked for this motor.
What should accompany a service enquiry?
Send clear motor and feedback labels, connector photographs, drive model, alarm text and fault history. Describe recent repair work and whether the problem appears at startup, during motion or after warming up.
What the service record should contain
Record the received model, serial or service ID, fitted feedback, mechanical condition and original fault before work begins. Include the test profile, connection boundary, fixture and supply/excitation used. Preserve readable original memory or parameter reports where relevant. Record evidence before and after each adjustment so an intermittent condition is not reported as a confirmed cure without a repeatable check.
The assessment should distinguish a confirmed defect, a proposed repair and any unresolved condition. State tests that need the machine, a missing drawing or a different fixture. Replacement availability, service timing and the final repair scope are confirmed after inspection.
Request a scoped service evaluation
Use the existing encoder enquiry form with the labels, alarm and connection photographs. Specify whether you need UAE field diagnosis, installation/alignment assessment or send-in testing. Turnaround and repair scope are confirmed after review of the fitted configuration.