Site visit or send-in evaluation
Send the full motor type code and material number, drive type and firmware, exact alarm, when it first appeared and photos of the connection box. Include the original motor and feedback board for alignment work. Arrange packing and intake before shipping. Use the enquiry form to share the details.
What specialist testing can show
Mitchell documents two distinct TI-5000JX setups for the MKD/MKE board assembly. The TI-5924 resolver lead is for signal and existing alignment checks. The TI-5040 revision C with TI-5104 adapter is the memory setup, with the resolver disconnected from the PCB while the assembly is safely off. Mitchell also documents a separate TI-3000JX generic resolver run test using the TI-5924 and the confirmed motor and excitation settings. That run test exercises the resolver and motor. Verify board communication on the intended Rexroth system as well. Mitchell MKD/MKE bench test and alignment procedure
Bosch Rexroth Indramat MKD071B-061 K Servo Feedback technical reference
Find your part number
Read the motor plate, including the three characters after the winding code and the final two characters. In MKD071B-061-KP0-KN, 071 is the size, B the length and 061 the winding. The first K selects multiturn feedback. P identifies the keyed driven shaft, 0 omits the holding brake and the last KN identifies the standard junction-box build. The two occurrences of K describe different things.
| Full motor code | Feedback option | Mechanical and connection differences |
|---|---|---|
| MKD071B-061-KP0-KN | K resolver with integrated multiturn absolute feedback | Keyed driven shaft, no holding brake, standard connection box |
| MKD071B-061-KP1-KN | K resolver with integrated multiturn absolute feedback | Keyed driven shaft, 5 Nm holding-brake option, standard connection box |
| MKD071B-061-GG0-KN | G resolver feedback, separate from the K multiturn option | Plain driven shaft, no holding brake, standard connection box |
Rexroth MKD071 ordering code (PDF) · Mitchell G/K board comparison
Production and end-of-life status
The Rexroth project-planning manual is a legacy installed-base reference. Exact production, repair exchange and replacement status for a given material number require a current Rexroth lookup. Record the number from the nameplate. Rexroth spare-parts lookup
Specifications
| Item | Documented scope |
|---|---|
| Motor poles | 4 pole pairs (8 poles) for winding 061. This is a motor value. |
| Characteristic / maximum motor speed | 4500 rpm characteristic, 6000 rpm maximum in Rexroth figure 8-3. Use the motor and drive limits for the actual installation. |
| Feedback architecture | K is resolver feedback with an integrated multiturn absolute encoder. Mitchell describes a battery, a magnet wheel and pickups on the K board. |
| Connection | The standard KN build in this guide has the 10-position motor-side X3 connection box. Its feedback cable is distinct from X1 motor power. |
| Brake option | KP0 has no brake. KP1 selects the 5 Nm holding brake. Mechanically secure the load before either version is disturbed. |
| Excitation and board supply | Confirm with the drive, board revision and documented service setup. Mitchell's test adapter is specific to its memory procedure. |
Rexroth 061 motor data (PDF) · Mitchell board and magnet-wheel notes
Mounting and fit
The resolver is inside the motor at the feedback end. Record the original connector position, orientation of the resolver parts, magnet wheel and board, and their mounting references before loosening anything. Inspect for a loose stator, shifted rotor or wheel, contamination, and a trapped lead when the unit is safely apart. The driven-shaft dimensions in Rexroth chapter 8 help identify the motor. Internal rotor/stator clearance, fastener torque and reassembly instructions must come from the exact service drawing or procedure. Rexroth motor dimensions and type code (PDF) · MKD feedback assembly reference
Interface and measuring method
The resolver produces angle-dependent signals from an excitation. The K assembly also tracks multiple revolutions and carries motor identification and alignment data in its feedback electronics. The Rexroth drive reads the feedback through the assigned motor connection. A resolver that produces smooth angle data can still be paired with a failed, incorrect or misprogrammed board. A drive readout with the wrong turn number or a loss of position after power-off also warrants checking the K battery and pickup system under the documented procedure. Mitchell digital Indramat interface and memory · MKD K hardware and checks
Verified wiring
Use this reference only for the standard connector-box X3 in Rexroth figure 12-2. Follow the manufacturer's contact numbers and drawing view. The two brown conductors have different functions. The internal six-pin green resolver plug and the circular connector on other MKD sizes require separate drawings.
| X3 position | Diagram signal | Rexroth cable colour |
|---|---|---|
| 1 | 0 V | White |
| 2 | FS | Black |
| 3 | S1 | Brown (0.25 mm²) |
| 4 | SCL | Red |
| 5 | S3 | Green |
| 6 | SDI | Blue |
| 7 | S2 | Gray |
| 8 | SDO | Violet |
| 9 | S4 | Pink |
| 10 | R1 | Brown (0.5 mm²) |
Use the drive-side schematic and Rexroth shield termination before making a cable. Match the internal plug to the board drawing and photograph its orientation before removal. A fitted connector alone does not establish correct orientation. Rexroth figure 12-2 connector box (PDF) · Mitchell internal plug note
Cables inside the motor and at the machine
For the motor-to-drive connection box arrangement, Rexroth figure 17-13 shows IKS4103 for the indicated direct path to HDD/HDS/DKC**.3 drives, using INK0448 cable. It separately draws intermediate paths. Order only after matching the exact drive, ends, length and topology. The inside-motor green resolver-to-board loom has no verified order code in the public documents used here. Match its housing, contacts and wiring to the original. TI-5924 and TI-5040 are specialist test leads. Rexroth encoder cable selection and figure 17-13 (PDF) · Mitchell test cable references
Fault checks
Before opening the connection box or turning the shaft. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized. Treat the K board backup battery as a separate energy source and preserve turn data before disturbing it.
- Record before resetting. From the existing display, capture the drive fault, motor identification, position and whether the alarm is present at boot, after motion or after power loss. Compare the motor plate and controller record.
- Inspect externally. Check X3 mating, glands, contamination, pulled contacts, shield clamp and cable routing. Check the driven coupling and load condition under isolation. A slipping coupling or jam can produce a following error with healthy feedback.
- Check the detached cable. With the harness isolated from the encoder and receiver at both ends, use resistance mode. First short the meter probes to establish lead resistance. Check each conductor end to end and flex the cable gently at the strain relief. Check between unrelated wires and from signal wires to shield or shell. Expect open only where the drawing calls for isolation. Compare any intentional sense links or shield bonds with the equipment drawing. Keep insulation testers away from connected electronics. Use the Rexroth diagram to distinguish the two brown conductors and the required shield bonds.
- Check supply and signals by the documented drive procedure. A qualified technician can use an approved breakout installed with power off. Compare the correct circuit to the drive manual under the specified conditions. Use separate bench setups to compare resolver response and board identification, stored alignment and turn data.
- Interpret the split. Good resolver response with bad board reads points to the board path, memory or its power. Good bench data with an installed alarm shifts attention to X3 cable, supply, controller compatibility or a drive-side feedback input. Good feedback with a mechanical following error calls for checking the load, brake and coupling.
Motor and drive applications
This guide applies to the standard Bosch Rexroth Indramat MKD071B-061 K-option servo and its documented connection box. Confirm the drive, firmware and drive-side feedback wiring before ordering. MDD, MHD, MKE, other MKD sizes and other connector schemes have separate service records. Rexroth connection system (PDF) · Mitchell Indramat family identification
Angle of alignment and commissioning
The motor needs its own measured or stored commutation relationship. Marking the original position helps preserve a mechanical reference. Before disassembly, a qualified specialist should record the original verified offset, direction, lockup reference, pole count and motor identity. On replacement, use the matching motor and board procedure to restore approved data only after checking actual resolver alignment. A write requires a compatible revision, verified source data and an independent commissioning check. If the original data are corrupt or missing, have the offset established for this motor and drive. Keep the machine datum and multiturn reference records separate. Mitchell read-before-teardown and alignment checks · Indramat commutation and derived data
Drawings, pin maps and manuals
- Bosch Rexroth MKD project-planning manual R911272495 (PDF). Manufacturer manual copy. Use chapter 8 for MKD071, chapter 12 for X3 and chapter 17 for encoder cables.
- Mitchell MKD/MKE resolver and digital board procedure. Explains independent resolver and board testing and the K turn-counter hardware.
- Mitchell Indramat digital feedback training. Family identification and motor-specific alignment background.
- Bosch Rexroth spare-parts reference. Search by the material number for current service or replacement options.