Identify the fitted part
| Guide scope | Bosch Rexroth MSK071E / NN / S2 — motor feedback application |
|---|---|
| Feedback identity | MSK option S2; fitted encoder full label required |
| Main model / application identifier | MSK071E / NN / S2 |
| Motor order scope | Frame/cooling/feedback configuration, not a complete inspected motor order |
| Interface | Singleturn EnDat 2.1 |
| Starting connection | TI-5093 + TI-5104 only through the verified motor-side 5 V regulator; direct EnDat: TI-5079, 5 V, NO TI-5104. |
Specialist testing: connection before conclusion
| TI-5000JX bench scope | Conditional TI-5000JX scope. MSK071E frame: singleturn EnDat; check E-length fit and feedback-specific housing dimensions. Keep direct 5 V encoder wiring separate from the regulated motor-side connection. Preserve motor memory and stored commutation offset. |
|---|---|
| Starting lead / fixture | TI-5093 + TI-5104 only through the verified motor-side 5 V regulator; direct EnDat: TI-5079, 5 V, NO TI-5104. |
| Profile / module | Keep direct 5 V encoder wiring separate from the regulated motor-side connection. Preserve motor memory and stored commutation offset. |
| TI-3000JX motor-run scope | Conditional documented MSK motor-run scope. Confirm winding, poles, motor-specific memory offset, power/brake connector, cooling and amplifier limits; frame size does not establish run capability. |
The documented test reference is Rexroth Motors — MSK supported family + HIPERFACE/EnDat; OEM printed pp.102, 123, 131; option S2. Verify installed tester software, the actual sensor option and the fixture before connection. A bench result describes the tested configuration; it does not by itself clear the complete drive, brake, machine cable or loaded axis.
Production and replacement status
The linked manufacturer record documents this configuration. Current production, stock and an approved successor for the complete fitted order still require manufacturer confirmation. A historical manual or downloadable CAD drawing does not prove present availability. Match voltage, mounting, shaft, brake, feedback, connector and motor-data requirements before ordering.
Specifications and interface
| Feedback technology | Singleturn EnDat 2.1 |
|---|---|
| Motor frame / length | MSK071E |
| Cooling option | NN: natural convection |
| Encoder option | S2 — Singleturn EnDat 2.1 |
| Position scope | Singleturn; this option alone does not retain the machine revolution count. |
| Outline drawing | OEM project planning manual printed p.102; type code p.123; encoder connection p.131 |
| Complete order required | Winding, connection orientation, shaft, brake and design suffix are not specified by this guide title. |
| Service values | Encoder coupling dimensions, exact pin map and tightening torque require the fitted assembly drawing. No value is inferred from a related motor. |
EnDat serial information and any associated incremental tracks have different functions. Confirm the actual encoder label and EnDat version, and evaluate the documented paths separately. A singleturn absolute reading does not establish the machine home position after mechanical work.
Mechanical fit and retention
Record the incoming shaft datum, pilot, bolt pattern, rear clearance, cable exit and retaining arrangement before removal. Use the exact drawing for tolerances and fastening. Do not infer encoder coupling dimensions or tightening torque from the motor flange size. Inspect looseness, bearing play, debris and moisture before disturbing the feedback attachment. The MSK071E outline on printed page 102 controls installation space. Read the length column for this frame and actual feedback/brake option. The U connector arrangement in the relevant type key allows a 240-degree orientation range; check the fitted order and cable clearance before adjustment.
MSK071E with NN cooling and S2 feedback is a frame/cooling/encoder configuration, not a complete motor order. MSK071E frame: singleturn EnDat; check E-length fit and feedback-specific housing dimensions. S2 geometry and order restrictions; do not substitute a HIPERFACE assembly.
Wiring and connector boundaries
Keep motor power, protective earth, feedback, temperature sensing and any holding brake as separate circuits. Establish contact numbering, keying, gender and whether the drawing shows the mating face or wire side. Do not infer a pin map from a connector shell. TI-5093 + TI-5104 only through the verified motor-side 5 V regulator; direct EnDat: TI-5079, 5 V, NO TI-5104. A direct HEIDENHAIN EnDat encoder uses the protected 5 V path such as the exact TI-5079 drawing; do not add TI-5104 to that direct path. At the documented MSK motor bulkhead, the regulated motor-side connection is a different boundary.
Starting connection for this guide: TI-5093 + TI-5104 only through the verified motor-side 5 V regulator; direct EnDat: TI-5079, 5 V, NO TI-5104.. Use the source below for its named scope. Any unverified pin assignment remains open until the correct drawing is available.
Internal loom and machine cables
Record the internal encoder-to-motor loom separately from the external machine cable and test fixture. The internal loom part number is not established by the motor model alone. Obtain the assembly drawing and both connector faces. Match cable length, shielding, temperature rating and fixed or flexing duty to the installation; a Mitchell test lead is not an OEM replacement cable.
Practical fault checks
Isolation and measurement conditions
Secure moving loads, isolate and lock out the relevant energy sources, follow the specified discharge time and have a qualified technician verify isolation before physical inspection or resistance checks. Disconnect both cable ends before continuity/short testing. Powered supply measurements, rotation, retention work and alignment require the approved fixture and procedure.
| Identify before testing | MSK071E with NN cooling and S2 feedback is a frame/cooling/encoder configuration, not a complete motor order. MSK071E frame: singleturn EnDat; check E-length fit and feedback-specific housing dimensions. S2 geometry and order restrictions; do not substitute a HIPERFACE assembly. |
|---|---|
| Intermittent fault with cable movement | After isolation and disconnection at both ends, inspect flex points, pin engagement, contamination and previous repairs. Compare continuity and unintended shorts with the exact diagram, allowing for intentional shield bonds. |
| No serial data or unstable position | Confirm the profile, low-voltage supply at the correct boundary and mating-face pin assignment. Compare the test fixture with the actual motor connector; a plausible connector fit does not prove electrical compatibility. |
| Feedback reads but the drive rejects it | Record the original alarm and check exact motor identity, stored data requirements, direction, mechanical attachment and the supported signal paths. A reset is not proof of a compatible replacement. |
| Replacement dimensions look close | Compare the exact model, shaft, pilot, brake, seal, cooling and connector options above with the linked drawing before ordering or removing the original assembly. |
Alignment, reference and memory
Preserve the original mechanical reference, motor phase convention, direction and readable drive data before disassembly. Use the fitted motor and encoder service procedure for replacement. Communication alone does not prove correct alignment or machine origin. MSK stores motor-specific information and an electronic commutation offset. Preserve the incoming data before supported memory or alignment work; do not write a generic angle.
Motor and drive applications
MSK071E, natural convection, Singleturn EnDat 2.1. MSK071E with NN cooling and S2 feedback is a frame/cooling/encoder configuration, not a complete motor order. MSK071E frame: singleturn EnDat; check E-length fit and feedback-specific housing dimensions. S2 geometry and order restrictions; do not substitute a HIPERFACE assembly.
A matching maker, connector shell or protocol name is not a complete compatibility chain. Keep motor order → feedback option → internal loom → bulkhead → machine cable → drive configuration recorded separately. No unverified alternate part is offered by this guide.
Drawings, manuals and evidence
- Rexroth Motors — MSK supported family + HIPERFACE/EnDat; OEM printed pp.102, 123, 131; option S2
- Rexroth MSK support — Named motor family and feedback option; row locator identifies scope
- Rexroth Motors — Named motor family and feedback option; row locator identifies scope
- Bosch Rexroth R911296289, IndraDyn S MSK Project Planning Manual, Edition 06 — Chapters 5–7: frame drawings, type codes and feedback options; 2006 revision, not a current availability statement
Obtain the complete fitted motor and encoder labels, exact service ID, internal loom, connector mating-face drawing and approved setup. Match the linked OEM document revision; unverified supply, pins, retention fasteners and alignment values remain open.
Common questions
What should accompany a MSK071E / NN / S2 enquiry?
Send clear photographs of the motor and feedback labels, every suffix/ID, both connector faces, drive model, exact alarm and the circumstances of the fault. Include recent wiring, bearing, encoder or parameter work.
Can the listed Mitchell lead be used as a replacement machine cable?
The lead is documented for the stated test connection. OEM internal looms and machine extensions require their own part numbers, pin maps and mechanical ratings.
Does a successful feedback bench test prove that the motor can be run?
Conditional documented MSK motor-run scope. Confirm winding, poles, motor-specific memory offset, power/brake connector, cooling and amplifier limits; frame size does not establish run capability. A complete run assessment also checks motor power, brake, protection and mechanical conditions.
When does a site visit or send-in evaluation make sense?
A site visit can help when the fault depends on the drive, installation or moving cable. Send-in evaluation can isolate a removable feedback assembly or supported motor configuration. Agree scope, packing, availability and turnaround with SpareFaber after identification.
Request a scoped service evaluation
Use the existing encoder enquiry form with the labels, alarm and connection photographs. Specify whether you need UAE field diagnosis, installation/alignment assessment or send-in testing. Turnaround and repair scope are confirmed after review of the fitted configuration.