Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
Use the compatible CNC's feedback monitor for position validity and axis travel. If a harness is fully disconnected, trace the named cable map and inspect both connectors. Compare the displayed displacement to a suitable reference during approved movement.
Fagor SV2AF10-1640-5-B-A-T FANUC Absolute Linear Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is SV2AF10-1640-5-B-A-T. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| SV2AF10-1640-5-B-A-T | 1640 mm measuring range, B mounting support, A reader-head air inlet, T M4 threaded head. | F selects FANUC α/αi. 10 specifies the 0.01 µm ordering option, subject to interface selection. |
| SV2A / SV2AS | Check measuring length and reader mounting independently. | SSI-family builds in the catalogue. Use their own connection and parameter set. |
| SV2ABC | Compare envelope, reader head and configured length. | BiSS C option. Requires a compatible receiver. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Measuring range | 1640 mm. The dimensional table gives M = 820 mm for this length. Use the drawing to identify M and the housing envelope. |
| Accuracy option | Code 5 selects the ±5 µm class in the ordering key. The technical table expresses the family accuracy as ±5 µm/m. |
| Supply | 5 V ±10%, less than 250 mA without load in the SV2A series specification. |
| Resolution and interface | Code 10 is the 0.01 µm order example. The technical table distinguishes α and αi resolution combinations. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
Use the dimensional view for the supported SV2A profile and 1640 mm measuring length. Locate the body and head using the prescribed references. Check that the axis has clear travel and cable support, and use the installation procedure for head spacing, fasteners and air connection.
Interface and measuring method
The head reads optical absolute code on the scale and sends position over FANUC α or αi communication. Confirm the exact controller generation and resolution before entering its scale factor. Check the catalogue's SV2AF row separately from the SSI and BiSS rows.
Verified wiring
The catalogue documents cable XC-M2-…D-FN with the eight-contact M12 connector and FANUC Honda/Hirose connector. The following map applies to that named cable. Match both connector faces and the drive specification first.
| Signal | M12 → Honda/Hirose |
|---|---|
| +5 V and 0 V | 8 → 9 and 5 → 12 |
| Supply sense + / − | 2 → 18 and 20 / 1 → 14 |
| REQ / inverse REQ | 7 → 5 / 6 → 6 |
| Data / inverse Data | 3 → 1 / 4 → 2 |
| Shield | M12 housing → 16 |
Cables inside the motor and at the machine
The catalogue lists XC-M2-…D-FN lengths of 5, 10, 15, 20 and 25 m. It also documents other FANUC connection styles. Match the fitted ends, manufacturer cable length limit and controller drawing before buying.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| No absolute position after replacement | Check FANUC interface, cable option, receiver parameters and the isolated supply path. |
| Position changes but travel is mis-scaled | Compare configured resolution, measured travel and machine reference. |
| Dropout or tight movement in a local area | Inspect reader alignment, cable strain, scale support and clearance through that position. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
This is the manufacturer order example for the supported scale profile and FANUC communications option. Check the machine's controller, axis configuration and exact full order before replacing.
Angle of alignment and commissioning
Set housing and head geometry using the appropriate installation drawing. Save the original reference and compensation parameters where the machine procedure supports it. Re-establish the datum and check repeatability at known positions.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- Fagor linear encoder catalogue. Use the SV2A technical and dimension tables, worked order code and XC-M2-…D-FN cable diagram.