What specialist testing can show
TI-5000JX bench. TI-5000JX resolver checks with TI-5901 on the documented M23 branch. Verify fitted excitation and connector.
TI-3000JX motor run. Confirm exact motor, resolver setup and supported fixture separately before a motor run.
Starting lead. TI-5901 for the documented Festo M23 resolver connection.
Festo EMMS-AS-55-M-LS-RR Resolver Motor Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| EMMS-AS-55-M-LS-RR · 1569788 | Festo’s exact resolver motor order in the manufacturer catalogue and data sheet. |
| EMMS-AS-55-M-LS-TM · 550111 | The EnDat multiturn version covered by TCG212. Use its separate motor drawing and test setup. |
| TI-5901 | Mitchell’s test lead for the documented M23 resolver branch. Match the actual motor connector. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Feedback | Passive resolver for Festo item 1569788. |
| Connection | The Festo size-55 resolver table gives an M23 signal connector with excitation and two return pairs. |
| Motor fit | Nominal flange size 55. Use the exact Festo motor outline for dimensions. |
Interface and measuring method
The drive sends AC excitation and computes rotor angle from the sine and cosine returns. Check the excitation path when both returns are absent. A continuity reading alone does not establish correct angular response.
Mounting and fit
Use the size-55 outline and the exact motor order for shaft, pilot and mounting dimensions. Record the installed resolver rotor and stator reference. Obtain the factory assembly drawing for internal fit and fasteners.
Wiring and connector scope
For the Festo size-55 resolver M23 view, identify these pairs. Verify the drawing orientation on the actual motor before tracing. Use the approved source for the fitted excitation rating.
| Contact or circuit | Documented scope |
|---|---|
| 1 / 2 | R1 excitation positive and R2 excitation negative. |
| 3 / 4 | S1 cosine positive and S3 cosine negative. |
| 5 / 6 | S2 sine positive and S4 sine negative. |
Internal motor and machine cables
TI-5901 is the documented test cable. Select the machine resolver cable from the Festo motor and drive table and source any internal resolver lead by the fitted connector and motor revision.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
A resolver is passive. Check isolated winding continuity against the matching drawing. Use the specified AC excitation on the approved test fixture for a signal check.
| Symptom | What to verify |
|---|---|
| Both returns are missing | Check excitation, connector seating and cable continuity on the documented pair. |
| One return is weak or intermittent | Trace its pair separately and compare the cable with the isolated resolver circuit. |
| Angle is smooth and the drive commutation is poor | Verify resolver polarity, rotor seating and original alignment. |
Angle of alignment and commissioning
Record the incoming angle, direction and motor configuration. Verify the installed resolver’s polarity and motor reference in the approved Festo procedure before powered operation.
Motor and drive applications
EMMS-AS flange size 55, item 1569788
Confirm fitted connector orientation, excitation and ratio, machine lead and internal resolver assembly.
Drawings, pin maps and manuals
- Festo EMME-AS, EMMS-AS and EMMT-AS Series. EMMS-AS resolver technical data and connector
- Festo item 1569788 technical data sheet. Exact EMMS-AS-55-M-LS-RR order and resolver feedback.
- Festo EMMS-AS catalogue and connection tables. Size-55 resolver M23 assignment and mechanical outline.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.