Georgii Kobold KSY 7623.20 D / RH HIPERFACE MT Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment
Georgii Kobold KSY 7623.20 D / RH — HIPERFACE MT. This guide helps identify the fitted feedback, distinguish a cable or setup fault and prepare a scoped repair, installation or alignment assessment. SpareFaber accepts UAE site-service and send-in evaluation enquiries after reviewing the motor/feedback labels and fault history.
Identification · Testing scope · Fault checks · Drawings and manuals · Service enquiry
Identify the fitted configuration
| Item | Verified scope |
|---|---|
| Manufacturer / application | Georgii Kobold KSY 7623.20 D / RH |
| Feedback | HIPERFACE MT — SRM 50 |
| Identifier scope | Base motor + feedback selection; remaining nameplate suffixes are not specified. |
| Motor mounting | Ø265 PCD / Ø230 pilot |
| Braked representative | KSY 7623.20 D / MD / RH / 400 V |
| Holding brake | MD; 145 Nm; 24 V |
| SpareFaber service reference | TCG1384 |
The service reference is not an OEM part number. Verify the complete fitted labels and connector revision before selecting a replacement or test connection.
Specialist feedback testing
TI-5000JX: identified SRS50 / SRM50 classic HIPERFACE feedback. Evaluate serial position and analogue signals; retain incoming alignment/memory.
Starting connection: TI-5069 direct-to-encoder, 8-pin Berg; motor feedback connector is separate.
Module / software: TI-5104 required. Match actual SRS/SRM and software selection; minimum firmware not specified in cited article.
TI-3000JX motor-run scope: TI-3000JX not established for each complete order. Family power-lead references do not prove connector fit or a released run profile.
Signals and specifications
| Parameter | Documented value / limit |
|---|---|
| OEM feedback code | RH |
| Documented fitted encoder | SRM 50 |
| Interface | HIPERFACE MT; serial position plus analogue sine/cosine channels |
| Serial position per revolution | 15 bit |
| Analogue signal periods per revolution | 1024; this is not a drive-scaled position count |
| Multiturn range | 4096 revolutions (12-bit turn field) |
| Feedback supply in KSY-D pin table | +8 V at pin 2; GND pin 7 |
| Motor voltage example | 400 V rated motor build; separate from feedback and brake supplies |
| Brake | MD; 145 Nm; 24 V |
| Encoder + brake dimension k | 526 mm; use the exact drawing and any special suffix |
Signal periods, serial position bits, turn range and drive-scaled counts describe different quantities. Use the exact encoder option and controller configuration when comparing readings.
Mechanical fit and retention
The KSY 7623.20 D is in the KSY 76.. group. The catalogue identifies Ø265 PCD / Ø230 pilot and an encoder-plus-brake dimension k of 526 mm. These measurements describe the motor mounting and housing, not the encoder shaft or bore. Compare the actual motor drawing and machine coupling before assessing interchangeability.
Read the encoder label and the motor’s complete special-build suffix before removing the rear assembly. The catalogue supports this family/option combination; it does not identify every internal coupling, retention screw torque or machine harness. Photograph the mounting and incoming mechanical reference. Do not infer an encoder air gap or tightening torque from a similar KSY motor.
Wiring and connector boundaries
The 12-contact motor feedback connector is shown in the KSY-D catalogue on PDF page 9. The table below follows that OEM signal assignment. Use the drawing to confirm connector view, pin orientation and keying; it is not a tester or drive-end wiring table.
| Motor feedback contact | OEM signal |
|---|---|
| 1 / 6 | DATA− / DATA+ |
| 2 | VCC (+8 V) |
| 4 / 8 | SIN / REFSIN |
| 5 / 9 | COS / REFCOS |
| 7 | GND |
| 3, 10, 11, 12 | Not connected in this OEM table |
Power, brake and thermal contacts are on a different connector. KSY 76.. uses different power-contact markings and contact sizes from KSY 16..–66... Match the correct column of the OEM diagram; never treat similarly shaped connectors as interchangeable.
Internal, machine and test cables
TI-5069 direct-to-encoder, 8-pin Berg; motor feedback connector is separate.
The direct-to-encoder lead connects inside the feedback assembly. It is not the machine cable and is not a mating lead for the motor’s external feedback connector. Confirm the internal connector before connection. No verified OEM internal loom or complete machine cable number is established for this exact special build; record both-end connector photos, labels and length to identify it.
Kobold’s Mitchell family entry lists power leads TI-3048 and TI-3029. Select neither solely from this page: the exact motor power connector and tester limits must match.
Practical fault checks
Follow the site isolation procedure before physical checks: secure the driven load, lock out relevant energy sources, observe the drive discharge time and have a qualified technician verify isolation. Disconnect both cable ends before continuity or short testing and account for intentional shield bonds. Powered measurements, rotation, brake release and alignment require the applicable specialist procedure.
| Observed symptom | Useful next check |
|---|---|
| No serial position | Confirm the actual feedback code, the documented supply/sense arrangement and connector contact condition. Isolate the external cable from the encoder before blaming the feedback. |
| Serial position reads, analogue quality is poor | Check the correct analogue channel pairs and selected period count; investigate cable damage, contamination and connector seating using the approved signal test. |
| Wrong direction or positioning after replacement | Compare full encoder option, drive scale, direction and motor alignment; do not solve a configuration mismatch by copying an offset from another motor. |
| Fault follows cable movement | With power isolated, inspect cable strain, pin retention, contamination and both-end continuity. Verify shield handling against the exact machine drawing. |
| Position changes after a power cycle | Distinguish the encoder turn value from drive offsets and machine referencing. Preserve readings and memory before any reset; do not assume a battery-based retention system. |
Alignment, offsets and memory
Record the motor’s full label, feedback label, incoming position, phase convention, direction and any stored offset or memory before disturbing the encoder. A successful position read does not prove correct motor commutation alignment. No numerical alignment angle or transferable memory image is established here for the complete motor order.
If the encoder is replaced or the mechanical reference is lost, obtain the motor-specific alignment method and confirm hardware/data compatibility before an offset or memory write. Preserve the original data and compare the completed motor assembly with the approved run procedure.
Production and replacement status
The linked KSY-D catalogue documents this historical configuration. It does not establish current stock, continued manufacture of every suffix or a drop-in successor. Confirm supply status and revision against the full fitted labels before a replacement recommendation.
Motor applications and related guides
RG identifies SRS50 single-turn; RH identifies SRM50 multiturn. Both are classic HIPERFACE with 1024 analogue periods per revolution. They are different from RS/RQ SKS36/SKM36 options and from HIPERFACE DSL.
Drawings and primary documents
- Georgii Kobold KSY-D catalogue — PDF pp. 5–9, 20–25.
- Mitchell: Georgii Kobold Motors — KSY-D row; KSY-D Encoder Systems attachment; KSY-D Connections.
- Mitchell TI-5069 — Part summary.
Application evidence: K1 pp.5–9,24–25; encoder + brake k 526 mm. K2: KSY-D row; Encoder Systems attachment, RH row and KSY 76.. fit row.
FAQ and service enquiry
Is RH interchangeable with another KSY feedback option?
RG identifies SRS50 single-turn; RH identifies SRM50 multiturn. Both are classic HIPERFACE with 1024 analogue periods per revolution. They are different from RS/RQ SKS36/SKM36 options and from HIPERFACE DSL. Verify mounting, wiring, drive support and alignment for the actual motor before substitution.
Does the brake create a different feedback guide?
No. The braked representative identifies a useful documented build; brake/no-brake and winding-only differences are not separate coverage. Brake wiring and release requirements still matter during service.
What should I send with a service enquiry?
Provide the complete motor and feedback labels, drive model, connector photos, alarm text, fault timing and previous repair/replacement history. Include cable labels and any OEM installation drawing. This lets SpareFaber distinguish a site investigation from a send-in feedback or motor assessment.
Request a UAE site visit or send-in evaluation. Scope, parts and turnaround are confirmed after the fitted configuration and fault are reviewed.
Enquire about this encoder or resolver
Tell us what needs checking. We’ll review the details and confirm the scope and quotation before booking chargeable work.