What specialist testing can show
TI-5000JX bench. Check SRS50 serial and incremental signals at the approved connection.
TI-3000JX motor run. Confirm torque-motor ratings, actual poles and alignment before assigning a run setup.
Starting lead. TI-5069 when the fitted direct SRS connector matches. Module TI-5104 for the documented compatible classic HIPERFACE fixture.
Georgii Kobold KTY-Q RG / SICK SRS50 HIPERFACE Torque Motor Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| KTY-Q with RG | Georgii Kobold’s type table lists SRS 50 HIPERFACE singleturn for this option. |
| RH | The OEM table lists a separate multiturn HIPERFACE option. Read the exact fitted encoder. |
| RE / RD options | The KTY-Q catalogue also lists EnDat feedback choices. Use the actual motor option to select the interface. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| RG digital position | 15-bit within-turn position in the OEM code table. |
| Process signals | 1,024 sine/cosine periods per turn in the stated RG option. |
| Motor assembly | Use the applicable KTY-Q frame drawing for fit, clearances and the separate connection view. |
| Mitchell fixture | TI-5069 on the verified direct SRS connector and matching HIPERFACE hardware. |
Interface and measuring method
The SRS 50 uses classic HIPERFACE with a serial parameter channel and analogue process signals. Check both while preserving the original machine and motor reference.
Mounting and fit
Use the KTY-Q frame outline and encoder system drawing for the complete motor order. Torque-motor installations can have application-specific load and shaft arrangements. Identify the fitted SRS50 mechanical suffix before replacement.
Wiring and connector scope
Use the KTY-Q Connections drawing for the exact motor. Confirm whether the direct encoder connector matches TI-5069. Trace signal pairs and the screen independently from motor power.
Internal motor and machine cables
Identify the installed motor-to-drive cable and the internal connector arrangement from the exact KTY-Q and drive orders. Record both connector views and any shield bonds before loom service.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Serial position reads but motion is noisy | Verify the sine/cosine process pairs and screen, then compare mechanical fit and repeatability. |
| Drive expects a different feedback option | Compare RG, RH and the actual drive configuration against the OEM table. |
| Fault started after shaft or bearing work | Review the incoming reference and installation drawings before adjusting the encoder. |
Angle of alignment and commissioning
Preserve the measured reference and the drive parameters. Use the exact pole and motor setup for a qualified commutation check after service, with the load secured.
Motor and drive applications
Georgii Kobold KTY-Q torque motor, RG option
Use the RG key to choose the SRS50 documentation and verify the torque-motor feedback connection.
Related SpareFaber guides
Drawings, pin maps and manuals
- Georgii Kobold Motors. KTY-Q Encoder Systems attachment, RG row and KTY-Q Connections
- SICK Stegmann Hiperface Serial Encoders. Supplementary reference for the stated model or setup.
- Georgii Kobold KTY-Q torque motor catalogue. OEM RG feedback code, SRS 50 data and motor connection and outline reference.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.